본문 바로가기
KERD
논문KCI 등재

The effect of powder A2/powder A3 mixing ratio on color and translucency parameters of dental porcelain

1

조회

0

다운로드

2

인용

0

참고문헌

키워드

초록

PURPOSE. The purpose of this study is to mix dental ceramic powder in varying ratios and evaluate the effect of the mixing ratio on color and translucency. MATERIALS AND METHODS. The ceramic powder of shade A3 of the same product was mixed with the shade A2 of three products: IPS e.max Ceram (Ivoclar Vivadent, Schaan, Liechtenstein), Vintage Halo (SHOFU Inc., Kyoto, Japan), and Ceramco 3 (Ceramco-Dentsply, Burlington, NJ, USA) in the following fixed ratios (0 wt%, 25 wt%, 50 wt%, 75 wt%, and 100 wt%) and then fired. A total of 150 specimen of ceramic fired were manufactured in a regular size (W: 8.5 mm, L: 10.5 mm, and H: 1.5 mm). For color and translucency, L*, a*, and b* were measured and Two-way analysis of variance (ANOVA) and One-way analysis of variance (ANOVA) were used for data analysis (α=0.05). RESULTS. The higher the mixing ratio was, L*, a*, and b* of IPS e.max Ceram were all increased, and L* of Vintage Halo was reduced and a* and b* were increased. L* and a* of Ceramco3 were reduced and b* of Ceramco3 was increased. Color difference (ΔE*ab) was increased in all three products as the mixing ratio got higher. Increased mixing ratios resulted in decreased translucency parameter (TP) values for IPS e.max Ceram but increased TP values for Vintage Halo and Ceramco3. CONCLUSION. In this limited study, CIE L*, a*, and b* were influenced by the mixing ratio of the A3 powders and porcelain powder mixtures represented a various color and translucency.

Abstract

PURPOSE. The purpose of this study is to mix dental ceramic powder in varying ratios and evaluate the effect of the mixing ratio on color and translucency. MATERIALS AND METHODS. The ceramic powder of shade A3 of the same product was mixed with the shade A2 of three products: IPS e.max Ceram (Ivoclar Vivadent, Schaan, Liechtenstein), Vintage Halo (SHOFU Inc., Kyoto, Japan), and Ceramco 3 (Ceramco-Dentsply, Burlington, NJ, USA) in the following fixed ratios (0 wt%, 25 wt%, 50 wt%, 75 wt%, and 100 wt%) and then fired. A total of 150 specimen of ceramic fired were manufactured in a regular size (W: 8.5 mm, L: 10.5 mm, and H: 1.5 mm). For color and translucency, L*, a*, and b* were measured and Two-way analysis of variance (ANOVA) and One-way analysis of variance (ANOVA) were used for data analysis (α=0.05). RESULTS. The higher the mixing ratio was, L*, a*, and b* of IPS e.max Ceram were all increased, and L* of Vintage Halo was reduced and a* and b* were increased. L* and a* of Ceramco3 were reduced and b* of Ceramco3 was increased. Color difference (ΔE*ab) was increased in all three products as the mixing ratio got higher. Increased mixing ratios resulted in decreased translucency parameter (TP) values for IPS e.max Ceram but increased TP values for Vintage Halo and Ceramco3. CONCLUSION. In this limited study, CIE L*, a*, and b* were influenced by the mixing ratio of the A3 powders and porcelain powder mixtures represented a various color and translucency.

참고문헌 (39)

  1. Paravina RD, "Optimization of tooth color and shade guide design", J Prosthodont, 16, pp.269~276 (2007)
  2. Paravina RD, "Performance assessment of dental shade guides", J Dent, 37, pp.e15~e20 (2009)
  3. Ginzburg M, "Tooth color matching systems and communication with dental laboratory in indirect restorations:2011 update", Refuat Hapeh Vehashinayim (1993), 29, pp.28~34 (2012)
  4. Rosenstiel SF, "Contemporary fixed prosthodontics" (2006), Elsevier Health Sciences
  5. Commission Internationale de l’Eclairage, "Colorimetry. 3rd ed. Publication CIE No. 15.3", Central Bureau of the CIE, ~ (2004)
  6. Lee YK, "Calculation of colour resulting from composite", compomer layering techniques, 2004, pp.31, 1102~1108
  7. Alshiddi IF, "A comparison of conventional visual and spectrophotometric shade taking by trained and untrained dental students", Aust Dent J, 60, pp.176~181 (2015)
  8. Kröger E, "In vitro comparison of instrumental and visual tooth shade determination under different illuminants", J Prosthet Dent (2015)
  9. Wang J, "Assessing the accuracy of computer color matching with a new dental porcelain shade system", J Prosthet Dent, 111, pp.247~253 (2014)
  10. AlGhazali N, "Performance assessment of Vita Easy Shade spectrophotometer on colour measurement of aesthetic dental materials", Eur J Prosthodont Restor Dent, 19, pp.168~174 (2011)
  11. Al Hamad KQ, "Spectrophotometric Analysis of the Influence of Metal Alloy Choice, Opaque Thickness, and Repeated Firing on the Shade of Metal Ceramic Restorations", J Esthet Restor Dent (2015)
  12. Odaira C, "Clinical evaluation of a dental color analysis system: the Crystaleye Spectrophotometer®", J Prosthodont Res, 55, pp.199~205 (2011)
  13. Suárez MJ, "Three-year clinical evaluation of In-Ceram Zirconia posterior FPDs", Int J Prosthodont, 17, pp.35~38 (2004)
  14. Ahn JS, "Difference in the translucency of all-ceramics by the illuminant", Dent Mater, 24, pp.1539~1544 (2008)
  15. Kursoglu P, "Translucency of ceramic material in different core-veneer combinations", J Prosthet Dent, 113, pp.48~53 (2015)
  16. Jiang L, "Effects of sintering temperature and particle size on the translucency of zirconium dioxide dental ceramic", J Mater Sci Mater Med, 22, pp.2429~2435 (2011)
  17. Yilmaz B, "Effect of repeated firings on the color of opaque porcelain applied on different dental alloys", J Prosthet Dent, 101, pp.395~404 (2009)
  18. Kerem Yılmaz, "The effect of repeated firings on the color change of dental ceramics using different glazing methods", The Journal of Advanced of Prosthodontics, 6(6), pp.427~433 (2014), 대한치과보철학회[DOI]
  19. Ozturk O, "The effect of ceramic thickness and number of firings on the color of two all-ceramic systems", J Prosthet Dent, 100, pp.99~106 (2008)
  20. Celik G, "The effect of repeated firings on the color of an all-ceramic system with two different veneering porcelain shades", J Prosthet Dent, 99, pp.203~208 (2008)
  21. Sahin V, "The effect of repeated firings on the color of an alumina ceramic system with two different veneering porcelain shades", J Prosthet Dent, 104, pp.372~378 (2010)
  22. Cho MS, "Changes in optical properties of enamel porcelain after repeated external staining", J Prosthet Dent, 95, pp.437~443 (2006)
  23. 김희경, "Effect of polishing and glazing on the color and spectral distribution of monolithic zirconia", The Journal of Advanced of Prosthodontics, 5(3), pp.296~304 (2013), 대한치과보철학회[DOI]
  24. Yilmaz C, "Color stability of glazed and polished dental porcelains", J Prosthodont, 17, pp.20~24 (2008)
  25. Ozcelik TB, "Colorimetric analysis of opaque porcelain fired to different base metal alloys used in metal ceramic restorations", J Prosthet Dent, 99, pp.193~202 (2008)
  26. Shokry TE, "Effect of core and veneer thicknesses on the color parameters of two all-ceramic systems", J Prosthet Dent, 95, pp.124~129 (2006)
  27. Vinay Chila Bachhav, "The effect of ceramic thickness and number of firings on the color of a zirconium oxide based all ceramic system fabricated using CAD", CAM technology, 2011, pp.3(2), 57~62[DOI]
  28. Corciolani G, "Influence of layering thickness on the color parameters of a ceramic system", Dent Mater, 26, pp.737~742 (2010)
  29. Wheeler RC, "An atlas of tooth form" (1969), Saunders
  30. Lee YK, "Layered color of all-ceramic core and veneer ceramics", J Prosthet Dent, 97, pp.279~286 (2007)
  31. Kim SJ, "Translucency and masking ability of various opaque-shade composite resins", J Dent, 37, pp.102~107 (2009)
  32. Johnston WM, "Translucency parameter of colorants for maxillofacial prostheses", Int J Prosthodont, 8, pp.79~86 (1995)
  33. Johnston WM, "Color measurement in dentistry", J Dent, 37, pp.e2~e6 (2009)
  34. Douglas RD, "Intraoral determination of the tolerance of dentists for perceptibility and acceptability of shade mismatch", J Prosthet Dent, 97, pp.200~208 (2007)
  35. Kristiansen J, "Assessment of a prototype computer colour matching system to reproduce natural tooth colour on ceramic restorations", J Dent, 39, pp.e45~e51 (2011)
  36. Haddad HJ, "Allocation of color space for different age groups using three-dimensional shade guide systems", Eur J Esthet Dent, 6, pp.94~102 (2011)
  37. Sluzker A, "Sensitivity of digital dental photo CIE L*a*b* analysis compared to spectrophotometer clinical assessments over 6 months", Am J Dent, 24, pp.300~304 (2011)
  38. Ghinea R, "Color difference thresholds in dental ceramics", J Dent, 38, pp.e57~e64 (2010)
  39. Paravina RD, "Color difference thresholds in dentistry", J Esthet Restor Dent, 27, pp.S1~S9 (2015)

관련 논문AI추천

Shade reproduction and the ability of lithium disilicate ceramics to mask dark substratesIravani Maryam, Panahandeh Narges, Shamszadeh Sayna, Sheikh-Al-Eslamian Seyedeh Mahsa, Torabzadeh Hassan대한치과보존학회 · Restorative Dentistry and Endodontics2020 · 제45권 제3호Effect of the amount of thickness reduction on color and translucency of dental monolithic zirconia ceramics김성훈, 김희경, 여인성, 이재봉, 하승룡, 한중석대한치과보철학회 · The Journal of Advanced of Prosthodontics2016 · 제8권 제1호Evaluation of the color reproducibility of all-ceramic restorations fabricated by the digital veneering method김기백, 김웅철, 김재홍, 김지환, 김혜영대한치과보철학회 · The Journal of Advanced of Prosthodontics2014 · 제6권 제2호The effect of coloring liquids on the translucency of zirconia frameworkAslihan Usumez, Erdal Eroglu, Ilkin Tuncel, Tugrul Sari대한치과보철학회 · The Journal of Advanced of Prosthodontics2013 · 제5권 제4호The effect of repeated firings on the color change of dental ceramics using different glazing methodsCaner Ozturk, Fehmi Gonuldas, Kerem Yılmaz대한치과보철학회 · The Journal of Advanced of Prosthodontics2014 · 제6권 제6호Influences of luting cement shade on the color of various translucent monolithic zirconia and lithium disilicate ceramics for veneer restorationsAhmed Almslam, Atif Alghamdi, Ghada Alrabeah, Meshari Azaaqi, Nawaf Alamro대한치과보철학회 · The Journal of Advanced of Prosthodontics2023 · 제15권 제5호

이 간행물의 다른 논문 (9건)