Evaluation of marginal fit of 2 CAD-CAM anatomic contour zirconia crown systems and lithium disilicate glass-ceramic crown
1
조회
0
다운로드
4
인용
0
참고문헌
키워드
초록
PURPOSE. This study was to evaluate the marginal fit of two CAD-CAM anatomic contour zirconia crown systems compared to lithium disilicate glass-ceramic crowns. MATERIALS AND METHODS. Shoulder and deep chamfer margin were formed on each acrylic resin tooth model of a maxillary first premolar. Two CAD-CAM systems (Prettau®Zirconia and ZENOSTAR®ZR translucent) and lithium disilicate glass ceramic (IPS e.max®press) crowns were made (n=16). Each crown was bonded to stone dies with resin cement (Rely X Unicem). Marginal gap and absolute marginal discrepancy of crowns were measured using a light microscope equipped with a digital camera (Leica DFC295) magnified by a factor of 100. Two-way analysis of variance (ANOVA) and posthoc Tukey’'s HSD test were conducted to analyze the significance of crown marginal fit regarding the finish line configuration and the fabrication system. RESULTS. The mean marginal gap of lithium disilicate glass ceramic crowns (IPS e.max®press) was significantly lower than that of the CAD-CAM anatomic contour zirconia crown system (Prettau®Zirconia) (P<.05). Both fabrication systems and finish line configurations significantly influenced the absolute marginal discrepancy (P<.05). CONCLUSION. The lithium disilicate glass ceramic crown (IPS e.max®press) had significantly smaller marginal gap than the CAD-CAM anatomic contour zirconia crown system (Prettau®Zirconia). In terms of absolute marginal discrepancy, the CAD-CAM anatomic contour zirconia crown system (ZENOSTAR®ZR translucent) had under-extended margin, whereas the CAD-CAM anatomic contour zirconia crown system (Prettau®Zirconia) and lithium disilicate glass ceramic crowns (IPS e.max®press) had overextended margins.
Abstract
PURPOSE. This study was to evaluate the marginal fit of two CAD-CAM anatomic contour zirconia crown systems compared to lithium disilicate glass-ceramic crowns. MATERIALS AND METHODS. Shoulder and deep chamfer margin were formed on each acrylic resin tooth model of a maxillary first premolar. Two CAD-CAM systems (Prettau®Zirconia and ZENOSTAR®ZR translucent) and lithium disilicate glass ceramic (IPS e.max®press) crowns were made (n=16). Each crown was bonded to stone dies with resin cement (Rely X Unicem). Marginal gap and absolute marginal discrepancy of crowns were measured using a light microscope equipped with a digital camera (Leica DFC295) magnified by a factor of 100. Two-way analysis of variance (ANOVA) and posthoc Tukey’'s HSD test were conducted to analyze the significance of crown marginal fit regarding the finish line configuration and the fabrication system. RESULTS. The mean marginal gap of lithium disilicate glass ceramic crowns (IPS e.max®press) was significantly lower than that of the CAD-CAM anatomic contour zirconia crown system (Prettau®Zirconia) (P<.05). Both fabrication systems and finish line configurations significantly influenced the absolute marginal discrepancy (P<.05). CONCLUSION. The lithium disilicate glass ceramic crown (IPS e.max®press) had significantly smaller marginal gap than the CAD-CAM anatomic contour zirconia crown system (Prettau®Zirconia). In terms of absolute marginal discrepancy, the CAD-CAM anatomic contour zirconia crown system (ZENOSTAR®ZR translucent) had under-extended margin, whereas the CAD-CAM anatomic contour zirconia crown system (Prettau®Zirconia) and lithium disilicate glass ceramic crowns (IPS e.max®press) had overextended margins.
참고문헌 (29)
- Filser F, "Reliability and strength of all-ceramic dental restorations fabricated by direct ceramic machining (DCM)", Int J Comput Dent, 4, pp.89~106 (2001)
- Conrad HJ, "Current ceramic materials and systems with clinical recommendations: a systematic review", J Prosthet Dent, 98, pp.389~404 (2007)
- Christel P, "Mechanical properties and short-term in-vivo evaluation of yttrium-oxide-partially-stabilized zirconia", J Biomed Mater Res, 23, pp.45~61 (1989)
- Kugel G, "Restoring anterior maxillary dentition using alumina- and zirconia-based CAD", CAM restorations, 2003, pp.24, 569~572
- Rekow D, "Computer-aided design and manufacturing in dentistry:a review of the state of the art", J Prosthet Dent, 58, pp.512~516 (1987)
- Yin L, "An overview of in vitro abrasive finishing & CAD", CAM of bioceramics in restorative dentistry, 2006, pp.46, 1013~1026
- Baig MR, "Evaluation of the marginal fit of a zirconia ceramic computer-aided machined (CAM)crown system", J Prosthet Dent, 104, pp.216~227 (2010)
- Preis V, "Wear performance of substructure ceramics and veneering porcelains", Dent Mater, 27, pp.796~804 (2011)
- 정유석, "A study on the in-vitro wear of the natural tooth structure by opposing zirconia or dental porcelain", The Journal of Advanced of Prosthodontics, 2(3), pp.111~115 (2010), 대한치과보철학회
- Felton DA, "Effect of in vivo crown margin discrepancies on periodontal health", J Prosthet Dent, 65, pp.357~364 (1991)
- Knoernschild KL, "Periodontal tissue responses after insertion of artificial crowns and fixed partial dentures", J Prosthet Dent, 84, pp.492~498 (2000)
- Kokubo Y, "Clinical marginal and internal gaps of Procera AllCeram crowns", J Oral Rehabil, 32, pp.526~530 (2005)
- Boening KW, "Clinical fit of Procera AllCeram crowns", J Prosthet Dent, 84, pp.419~424 (2000)
- May KB, "Precision of fit: the Procera AllCeram crown", J Prosthet Dent, 80, pp.394~404 (1998)
- Weaver JD, "Marginal adaptation of castable ceramic crowns", J Prosthet Dent, 66, pp.747~753 (1991)
- Behr M, "The bond strength of the resin-to-zirconia interface using different bonding concepts", J Mech Behav Biomed Mater, 4, pp.2~8 (2011)
- McLean JW, "The estimation of cement film thickness by an in vivo technique", Br Dent J, 131, pp.107~111 (1971)
- Martínez-Rus F, "Evaluation of the absolute marginal discrepancy of zirconia-based ceramic copings", J Prosthet Dent, 105, pp.108~114 (2011)
- Pera P, "In vitro marginal adaptation of alumina porcelain ceramic crowns", J Prosthet Dent, 72, pp.585~590 (1994)
- Cho SH, "Effect of die spacer thickness on shear bond strength of porcelain laminate veneers", J Prosthet Dent, 95, pp.201~208 (2006)
- Holmes JR, "Considerations in measurement of marginal fit", J Prosthet Dent, 62, pp.405~408 (1989)
- Blackman R, "Marginal accuracy and geometry of cast titanium copings", J Prosthet Dent, 67, pp.435~440 (1992)
- Oruç S, "Fit of titanium and a base metal alloy metal-ceramic crown", J Prosthet Dent, 83, pp.314~318 (2000)
- Gavelis JR, "The effect of various finish line preparations on the marginal seal and occlusal seat of full crown preparations", J Prosthet Dent, 45, pp.138~145 (1981)
- Han HS, "Marginal accuracy and internal fit of machine-milled and cast titanium crowns", J Prosthet Dent, 106, pp.191~197 (2011)
- Witkowski S, "Marginal accuracy of titanium copings fabricated by casting and CAD", CAM techniques, 2006, pp.96, 47~52
- Tan PL, "An in vitro comparison of vertical marginal gaps of CAD", CAM titanium and conventional cast restorations, 2008, pp.17, 378~383
- Bornemann G, "Innovative method for the analysis of the internal 3D fitting accuracy of Cerec-3crowns", Int J Comput Dent, 5, pp.177~182 (2002)
- Quante K, "Marginal and internal fit of metal-ceramic crowns fabricated with a new laser melting technology", Dent Mater, 24, pp.1311~1315 (2008)
