The effect of different cooling rates and coping thicknesses on the failure load of zirconia-ceramic crowns after fatigue loading
2
조회
0
다운로드
1
인용
0
참고문헌
키워드
초록
PURPOSE. The purpose of this study was to evaluate the influence of different coping thicknesses and veneer ceramic cooling rates on the failure load of zirconia-ceramic crowns. MATERIALS AND METHODS. Zirconia copings of two different thicknesses (0.5 mm or 1.5 mm; n=20 each) were fabricated from scanning 40 identical abutment models using a dental computer-aided design and computer-aided manufacturing system. Zirconiaceramic crowns were completed by veneering feldspathic ceramics under different cooling rates (conventional or slow, n=20 each), resulting in 4 different groups (CONV05, SLOW05, CONV15, SLOW15; n=10 per group). Each crown was cemented on the abutment. 300,000 cycles of a 50-N load and thermocycling were applied on the crown, and then, a monotonic load was applied on each crown until failure. The mean failure loads were evaluated with two-way analysis of variance (P=.05). RESULTS. No cohesive or adhesive failure was observed after fatigue loading with thermocycling. Among the 4 groups, SLOW15 group (slow cooling and 1.5 mm chipping thickness) resulted in a significantly greater mean failure load than the other groups (P<.001). Coping fractures were only observed in SLOW15 group. CONCLUSION. The failure load of zirconia-ceramic crowns was significantly influenced by cooling rate as well as coping thickness. Under conventional cooling conditions, the mean failure load was not influenced by the coping thickness; however, under slow cooling conditions, the mean failure load was significantly influenced by the coping thickness.
Abstract
PURPOSE. The purpose of this study was to evaluate the influence of different coping thicknesses and veneer ceramic cooling rates on the failure load of zirconia-ceramic crowns. MATERIALS AND METHODS. Zirconia copings of two different thicknesses (0.5 mm or 1.5 mm; n=20 each) were fabricated from scanning 40 identical abutment models using a dental computer-aided design and computer-aided manufacturing system. Zirconiaceramic crowns were completed by veneering feldspathic ceramics under different cooling rates (conventional or slow, n=20 each), resulting in 4 different groups (CONV05, SLOW05, CONV15, SLOW15; n=10 per group). Each crown was cemented on the abutment. 300,000 cycles of a 50-N load and thermocycling were applied on the crown, and then, a monotonic load was applied on each crown until failure. The mean failure loads were evaluated with two-way analysis of variance (P=.05). RESULTS. No cohesive or adhesive failure was observed after fatigue loading with thermocycling. Among the 4 groups, SLOW15 group (slow cooling and 1.5 mm chipping thickness) resulted in a significantly greater mean failure load than the other groups (P<.001). Coping fractures were only observed in SLOW15 group. CONCLUSION. The failure load of zirconia-ceramic crowns was significantly influenced by cooling rate as well as coping thickness. Under conventional cooling conditions, the mean failure load was not influenced by the coping thickness; however, under slow cooling conditions, the mean failure load was significantly influenced by the coping thickness.
참고문헌 (33)
- Tinschert J, "Clinical behavior of zirconia-based fixed partial dentures made of DC-Zirkon: 3-year results", Int J Prosthodont, 21, pp.217~222 (2008)
- Schmitt J, "Zirconia posterior fixed partial dentures: a prospective clinical 3-year follow-up", Int J Prosthodont, 22, pp.597~603 (2009)
- Pelaez J, "A four-year prospective clinical evaluation of zirconia and metalceramic posterior fixed dental prostheses", Int J Prosthodont, 25, pp.451~458 (2012)
- Cosgarea R, "Peri-implant soft tissue colour around titanium and zirconia abutments: a prospective randomized controlled clinical study", Clin Oral Implants Res, 26, pp.537~544 (2015)
- Sax C, "10-year clinical outcomes of fixed dental prostheses with zirconia frameworks", Int J Comput Dent, 14, pp.183~202 (2011)
- Burke FJ, "Five-year clinical evaluation of zirconia-based bridges in patients in UK general dental practices", J Dent, 41, pp.992~999 (2013)
- Rinke S, "Prospective evaluation of zirconia posterior fixed partial dentures: 7-year clinical results", Int J Prosthodont, 26, pp.164~171 (2013)
- Rojas-Vizcaya F, "Full zirconia fixed detachable implant-re-tained restorations manufactured from monolithic zirconia:clinical report after two years in service", J Prosthodont, 20, pp.570~576 (2011)
- Limmer B, "Complications and patient-centered outcomes with an implant-supported monolithic zirconia fixed dental prosthesis: 1 year results", J Prosthodont, 23, pp.267~275 (2014)
- Aboushelib MN, "Bridging the gap between clinical failure and laboratory fracture strength tests using a fractographic approach", Dent Mater, 25, pp.383~391 (2009)
- Saito A, "A comparison of bond strength of layered veneering porcelains to zirconia and metal", J Prosthet Dent, 104, pp.247~257 (2010)
- Tholey MJ, "Thermal gradients and residual stresses in veneered Y-TZP frameworks", Dent Mater, 27, pp.1102~1110 (2011)
- Bonfante EA, "Thermal", mechanical simulation and laboratory fatigue testing of an alternative yttria tetragonal zirconia polycrystal core-veneer all-ceramic layered crown design, 2010, pp.118, 202~209
- Silva NR, "Modified Y-TZP core design improves all-ceramic crown reliability", J Dent Res, 90, pp.104~108 (2011)
- Aboushelib MN, "Microtensile bond strength of different components of core veneered all-ceramic restorations. Part II: Zirconia veneering ceramics", Dent Mater, 22, pp.857~863 (2006)
- Aboushelib MN, "Innovations in bonding to zirconiabased materials. Part II: Focusing on chemical interactions", Dent Mater, 25, pp.989~993 (2009)
- Swain MV, "Unstable cracking (chipping) of veneering porcelain on all-ceramic dental crowns and fixed partial dentures", Acta Biomater, 5, pp.1668~1677 (2009)
- Guazzato M, "Influence of thickness and cooling rate on development of spontaneous cracks in porcelain", zirconia structures, 2010, pp.55, 306~310
- Mainjot AK, "Influence of cooling rate on residual stress profile in veneering ceramic: measurement by hole-drilling", Dent Mater, 27, pp.906~914 (2011)
- Belli R, "Thermal-induced residual stresses affect the lifetime of zirconia-veneer crowns", Dent Mater, 29, pp.181~190 (2013)
- Belli R, "A photoelastic assessment of residual stresses in zirconia-veneer crowns", J Dent Res, 91, pp.316~320 (2012)
- Meira JB, "Residual stresses in Y-TZP crowns due to changes in the thermal contraction coefficient of veneers", Dent Mater, 29, pp.594~601 (2013)
- Mainjot AK, "Influence of zirconia framework thickness on residual stress profile in veneering ceramic: measurement by hole-drilling", Dent Mater, 28, pp.378~384 (2012)
- Mainjot AK, "Influence of veneer thickness on residual stress profile in veneering ceramic: measurement by hole-drilling", Dent Mater, 28, pp.160~167 (2012)
- Rosentritt M, "Fracture performance of computer-aided manufactured zirconia and alloy crowns", Quintessence Int, 40, pp.655~662 (2009)
- Alhasanyah A, "Effect of core thickness differences on post-fatigue indentation fracture resistance of veneered zirconia crowns", J Prosthodont, 22, pp.383~390 (2013)
- Larsson C, "Fracture strength of yttria-stabilized tetragonal zirconia polycrystals crowns with different design: an in vitro study", Clin Oral Implants Res, 23, pp.820~826 (2012)
- Rosentritt M, "Influence of substructure design and spacer settings on the in vitro performance of molar zirconia crowns", J Dent, 37, pp.978~983 (2009)
- Guess PC, "Effect of core design and veneering technique on damage and reliability of Y-TZP-supported crowns", Dent Mater, 29, pp.307~316 (2013)
- Sailer I, "Randomized controlled clinical trial of zirconia-ceramic and metal-ceramic posterior fixed dental prostheses: a 3-year follow-up", Int J Prosthodont, 22, pp.553~560 (2009)
- Schwarz S, "Survival and chipping of zirconia-based and metal-ceramic implant-supported single crowns", Clin Implant Dent Relat Res, 14, pp.e119~e125 (2012)
- Rues S, "Effect of firing protocols on cohesive failure of all-ceramic crowns", J Dent, 38, pp.987~994 (2010)
- Rinke S, "Practice-based clinical evaluation of metal-ceramic and zirconia molar crowns: 3-year results", J Oral Rehabil, 40, pp.228~237 (2013)
