본문 바로가기
KERD
논문KCI 등재

Fracture resistance and marginal fit of the zirconia crowns with varied occlusal thickness

2

조회

0

다운로드

2

인용

0

참고문헌

키워드

초록

PURPOSE. The present study aimed to evaluate the clinical applicability of monolithic zirconia (MZ) crowns of different thickness via determination of fracture resistance and marginal fit. MATERIALS AND METHODS. MZ crowns with 0.5, 0.8, 1.0, and 1.5 mm thickness and porcelain fused to metal (PFM) crowns were prepared, ten crowns in each group. Marginal gaps of the crowns were measured. All crowns were aged with thermal cycling (5 - 55oC/10000 cycle) and chewing simulator (50 N/1 Hz/lateral movement: 2 mm, mouth opening: 2 mm/240000 cycles). After aging, fracture resistance of crowns was determined. Statistical analysis was performed with one-way ANOVA and Tukey’s HDS post hoc test. RESULTS. Fracture loads were higher in the PFM and 1 mm MZ crowns compared to 0.5 mm and 0.8 mm crowns. 1.5 mm MZ crowns were not broken even with the highest force applied (10 kN). All marginal gap values were below 86 um even in the PFM crowns, and PFM crowns had a higher marginal gap than the MZ crowns. CONCLUSION. The monolithic zirconia exhibited high fracture resistance and good marginal fit even with the 0.5 mm thickness, which might be used with reduced occlusal thickness and be beneficial in challengingly narrow interocclusal space.

Abstract

PURPOSE. The present study aimed to evaluate the clinical applicability of monolithic zirconia (MZ) crowns of different thickness via determination of fracture resistance and marginal fit. MATERIALS AND METHODS. MZ crowns with 0.5, 0.8, 1.0, and 1.5 mm thickness and porcelain fused to metal (PFM) crowns were prepared, ten crowns in each group. Marginal gaps of the crowns were measured. All crowns were aged with thermal cycling (5 - 55oC/10000 cycle) and chewing simulator (50 N/1 Hz/lateral movement: 2 mm, mouth opening: 2 mm/240000 cycles). After aging, fracture resistance of crowns was determined. Statistical analysis was performed with one-way ANOVA and Tukey’s HDS post hoc test. RESULTS. Fracture loads were higher in the PFM and 1 mm MZ crowns compared to 0.5 mm and 0.8 mm crowns. 1.5 mm MZ crowns were not broken even with the highest force applied (10 kN). All marginal gap values were below 86 um even in the PFM crowns, and PFM crowns had a higher marginal gap than the MZ crowns. CONCLUSION. The monolithic zirconia exhibited high fracture resistance and good marginal fit even with the 0.5 mm thickness, which might be used with reduced occlusal thickness and be beneficial in challengingly narrow interocclusal space.

참고문헌 (50)

  1. Komine F, "Current status of zirconia-based fixed restorations", J Oral Sci, 52, pp.531~539 (2010)
  2. Vidotti HA, "Influence of thermal and mechanical fatigue on the shear bond strength of different all-ceramic systems", J Clin Exp Dent, 9, pp.e952~7 (2017)
  3. Stawarczyk B, "Three generations of zirconia: From veneered to monolithic. Part II", Quintessence Int, 48, pp.441~450 (2017)
  4. Sailer I, "All-ceramic or metal-ceramic tooth-supported fixed dental prostheses (FDPs)? A systematic review of the survival and complication rates. Part I: Single crowns (SCs)", Dent Mater, 31, pp.603~623 (2015)
  5. Church TD, "Translucency and strength of high-translucency monolithic zirconium oxide materials", Gen Dent, 65, pp.48~52 (2017)
  6. Sun T, "Load-bearing capacity and the recommended thickness of dental monolithic zirconia single crowns", J Mech Behav Biomed Mater, 35, pp.93~101 (2014)
  7. Ahmed WM, "Marginal discrepancies of monolithic zirconia crowns : The influence of preparation designs and sintering techniques", J Prosthodont, 28, pp.288~298 (2019)
  8. Schriwer C, "Monolithic zirconia dental crowns. Internal fit, margin quality, fracture mode and load at fracture", Dent Mater, 33, pp.1012~1020 (2017)
  9. Turkoglu P, "Evaluation of dual-cure resin cement polymerization under different types and thicknesses of monolithic zirconia", Biomed Res Int, 2019, pp.4567854~ (2019)
  10. Shillingburg HT, "Fundamentals of fixed prosthodontics", pp.281~307 (1997), Quintessence
  11. Gergo Mitov, "Influence of the preparation design and artificial aging on the fracture resistance of monolithic zirconia crowns", The Journal of Advanced of Prosthodontics, 8(1), pp.30~36 (2016), 대한치과보철학회[DOI]
  12. "Zirconia. Technical information" (2020)[URL]
  13. Cho LR, "Marginal accuracy and fracture strength of ceromer", fiber-reinforced composite crowns : Effect of variations in preparation design, 2002, pp.88, 388~395
  14. Flinn BD, "Influence of aging on flexural strength of translucent zirconia for monolithic restorations", J Prosthet Dent, 117, pp.303~309 (2017)
  15. Kaleli N, "The effect of layer thickness on the porcelain bond strength of laser-sintered metal frameworks", J Prosthet Dent, 122, pp.76~81 (2019)
  16. Kokubo Y, "Clinical marginal and internal gaps of zirconia all-ceramic crowns", J Prosthodont Res, 55, pp.40~43 (2011)
  17. Sarıkaya I, "Effects of dynamic aging on the wear and fracture strength of monolithic zirconia restorations", BMC Oral Health, 18, pp.146~ (2018)
  18. Beuer F, "In vitro performance of full-contour zirconia single crowns", Dent Mater, 28, pp.449~456 (2012)
  19. Ferrario VF, "Maximal bite forces in healthy young adults as predicted by surface electromyography", J Dent, 32, pp.451~457 (2004)
  20. Shahmiri R, "Optical properties of zirconia ceramics for esthetic dental restorations : A systematic review", J Prosthet Dent, 119, pp.36~46 (2018)
  21. Yu Lung Tang, "The effect of different cooling rates and coping thicknesses on the failure load of zirconia-ceramic crowns after fatigue loading", The Journal of Advanced of Prosthodontics, 9(3), pp.152~158 (2017), 대한치과보철학회[DOI]
  22. Biesuz M, "Investigation of electrochemical, optical and thermal effects during flash sintering of 8YSZ", Materials(Basel), 11, pp.1214~ (2018)
  23. Wataha JC, "Alloys for prosthodontic restorations", J Prosthet Dent, 87, pp.351~363 (2002)
  24. Dhima M, "Evaluation of fracture resistance in aqueous environment under dynamic loading of lithium disilicate restorative systems for posterior applications. Part 2", J Prosthodont, 23, pp.353~357 (2014)
  25. Preis V, "Wear performance of substructure ceramics and veneering porcelains", Dent Mater, 27, pp.796~804 (2011)
  26. Gierthmuehlen P, "Effect of reduced material thickness on fatigue behavior and failure load of monolithic CAD", CAM PICN molar crowns, 2019, pp.32, 71~74
  27. Dikicier S, "Influence of core thickness and artificial aging on the biaxial flexural strength of different all-ceramic materials : An in-vitro study", Dent Mater J, 36, pp.296~302 (2017)
  28. Yin R, "Effect of finishing condition on fracture strength of monolithic zirconia crowns", Dent Mater J, 38, pp.203~210 (2019)
  29. Kim JH, "Fracture load of zirconia crowns according to the thickness and marginal design of coping", J Prosthet Dent, 108, pp.96~101 (2012)
  30. Nakamura K, "Critical considerations on load-tofailure test for monolithic zirconia molar crowns", J Mech Behav Biomed Mater, 87, pp.180~189 (2018)
  31. Sorrentino R, "In vitro analysis of the fracture resistance of CAD-CAM monolithic zirconia molar crowns with different occlusal thickness", J Mech Behav Biomed Mater, 61, pp.328~333 (2016)
  32. 최슬기, "Load-bearing capacity of various CAD", CAM monolithic molar crowns under recommended occlusal thickness and reduced occlusal thickness conditions, 2017, pp.9(6), 423~431[DOI]
  33. Dahl BL, "Dentine", pulp reactions to full crown preparation procedures, 1977, pp.4, 247~254
  34. Vigolo P, "An in vivo evaluation of the fit of zirconium-oxide based, ceramic single crowns with vertical and horizontal finish line preparations", J Prosthodont, 24, pp.603~609 (2015)
  35. Philipp A, "Novel ceria-stabilized tetragonal zirconia", alumina nanocomposite as framework material for posterior fixed dental prostheses : preliminary results of a prospective case series at 1 year of function, 2010, pp.41, 313~319
  36. Pera P, "In vitro marginal adaptation of alumina porcelain ceramic crowns", J Prosthet Dent, 72, pp.585~590 (1994)
  37. McLean JW, "The estimation of cement film thickness by an in vivo technique", Br Dent J, 131, pp.107~111 (1971)
  38. Fransson B, "The fit of metal-ceramic crowns, a clinical study", Dent Mater, 1, pp.197~199 (1985)
  39. Freire Y, "The marginal fit of CAD", CAM monolithic ceramic and metal-ceramic crowns, 2019, pp.28, 299~304
  40. 하석준, "Comparison of the fit accuracy of zirconia-based prostheses generated by two CAD", CAM systems, 2016, pp.8(6), 439~448[DOI]
  41. Shembesh M, "An in vitro comparison of the marginal adaptation accuracy of CAD", CAM restorations using different impression systems, 2017, pp.26, 581~586
  42. 지민경, "Evaluation of marginal fit of 2 CAD-CAM anatomic contour zirconia crown systems and lithium disilicate glass-ceramic crown", The Journal of Advanced of Prosthodontics, 7(4), pp.271~277 (2015), 대한치과보철학회[DOI]
  43. Kale E, "Effect of cement space on the marginal fit of CAD-CAM-fabricated monolithic zirconia crowns", J Prosthet Dent, 116, pp.890~895 (2016)
  44. Kocaağaoğlu H, "Effect of digital impressions and production protocols on the adaptation of zirconia copings", J Prosthet Dent, 117, pp.102~108 (2017)
  45. Rimondini L, "Bacterial colonization of zirconia ceramic surfaces : an in vitro and in vivo study", Int J Oral Maxillofac Implants, 17, pp.793~798 (2002)
  46. Pandoleon P, "Aging of 3Y-TZP dental zirconia and yttrium depletion", Dent Mater, 33, pp.e385~e392 (2017)
  47. Lai X, "Effects of small-grit grinding and glazing on mechanical behaviors and ageing resistance of a super-translucent dental zirconia", J Dent, 66, pp.23~31 (2017)
  48. Yang SW, "Enamel wear and aging of translucent zirconias : In vitro and clinical studies", J Prosthet Dent, 121, pp.417~425 (2019)
  49. Stawarczyk B, "Comparison of four monolithic zirconia materials with conventional ones: Contrast ratio, grain size, four-point flexural strength and two-body wear", J Mech Behav Biomed Mater, 59, pp.128~138 (2016)
  50. Muñoz EM, "The effects of mechanical and hydrothermal aging on microstructure and biaxial flexural strength of an anterior and a posterior monolithic zirconia", J Dent, 63, pp.94~102 (2017)

이 간행물의 다른 논문 (9건)