PURPOSE. Temperature increase of 5.5 °C can cause damage or necrosis of the pulp. Increasing temperature can be caused not only by mechanical factors, e.g. grinding, but also by exothermic polymerization reactions of resin materials. The aim of this study was to evaluate influences of the form material on the intrapulpal temperature during the polymerization of different self-curing resin materials for temporary restorations. MATERIALS AND METHODS. 30 provisonal bridges were made of 5 resin materials: Prevision Temp (Pre), Protemp 4 (Pro), Luxatemp Star (Lux), Structure 3 (Str) and an experimental material (Exp). Moulds made of alginate (A) and of silicone (S) and vacuum formed moulds (V) were used to build 10 bridges each on a special experimental setup. The intrapulpal temperatures of three abutment teeth (a canine, a premolar, and a molar,) were measured during the polymerization every second under isothermal conditions. Comparisons of the maximum temperature (TMax) and the time until the maximum temperature (tTMax) were performed using ANOVA and Tukey Test. RESULTS. Using alginate as the mould material resulted in a cooling effect for every resin material. Using the vacuum formed mould, TMax increased significantly compared to alginate (P<.001) and silicone (P<.001). In groups Lux, Pro, and Pre, tTMax increased when the vacuum formed moulds were used. In groups Exp and Str, there was no influence of the mould material on tTMax. CONCLUSION. All of the mould materials are suitable for clinical use if the intraoral application time does not exceed the manufacturer’s instructions for the resin materials.

Abstract

PURPOSE. Temperature increase of 5.5 °C can cause damage or necrosis of the pulp. Increasing temperature can be caused not only by mechanical factors, e.g. grinding, but also by exothermic polymerization reactions of resin materials. The aim of this study was to evaluate influences of the form material on the intrapulpal temperature during the polymerization of different self-curing resin materials for temporary restorations. MATERIALS AND METHODS. 30 provisonal bridges were made of 5 resin materials: Prevision Temp (Pre), Protemp 4 (Pro), Luxatemp Star (Lux), Structure 3 (Str) and an experimental material (Exp). Moulds made of alginate (A) and of silicone (S) and vacuum formed moulds (V) were used to build 10 bridges each on a special experimental setup. The intrapulpal temperatures of three abutment teeth (a canine, a premolar, and a molar,) were measured during the polymerization every second under isothermal conditions. Comparisons of the maximum temperature (TMax) and the time until the maximum temperature (tTMax) were performed using ANOVA and Tukey Test. RESULTS. Using alginate as the mould material resulted in a cooling effect for every resin material. Using the vacuum formed mould, TMax increased significantly compared to alginate (P<.001) and silicone (P<.001). In groups Lux, Pro, and Pre, tTMax increased when the vacuum formed moulds were used. In groups Exp and Str, there was no influence of the mould material on tTMax. CONCLUSION. All of the mould materials are suitable for clinical use if the intraoral application time does not exceed the manufacturer’s instructions for the resin materials.

참고문헌 (17)

  1. Kim SH, "Exotherm behavior of the polymerbased provisional crown and fixed partial denture materials", Dent Mater, 20, pp.383~387 (2004)
  2. Barlattani A, "Polymerization exothermal reaction of dental prosthetic resin for temporary crowns. A comparative evaluation", Minerva Stomatol, 51, pp.11~20 (2002)
  3. Zach l, "Pulp response to externally applied heat", Oral Surg Oral Med Oral Pathol, 19, pp.515~530 (1965)
  4. Baldissara P, "Clinical and histological evaluation of thermal injury thresholds in human teeth: a preliminary study", J Oral Rehabil, 24, pp.791~801 (1997)
  5. Amano T, "Responses of rat pulp cells to heat stress in vitro", J Dent Res, 85, pp.432~435 (2006)
  6. 권수정, "Thermal irritation of teeth during dental treatment procedures", Restorative Dentistry and Endodontics, 38(3), pp.105~112 (2013), 대한치과보존학회[DOI]
  7. Castelnuovo J, "Temperature rise in pulpal chamber during fabrication of provisional resinous crowns", J Prosthet Dent, 78, pp.441~446 (1997)
  8. Chiodera G, "Temperature change in pulp cavity in vitro during the polymerization of provisional resins", Dent Mater, 25, pp.321~325 (2009)
  9. Lenz E, "Comparative study on the biological properties of plastics for temporary crowns and bridges", Stomatol DDR, 40, pp.100~102 (1990)
  10. Firoozmand L, "Temperature rise in cavities prepared by high and low torque handpieces and Er:YAG laser", Br Dent J, 205, pp.E1~ (2008)
  11. Srimaneepong V, "Pulpal space pressure and temperature changes from Nd:YAG laser irradiation of dentin", J Dent, 30, pp.291~296 (2002)
  12. Bevilacqua L, "Reaction exothermia of 2 relining resins for temporary crowns", Minerva Stomatol, 54, pp.35~41 (2005)
  13. Piplani A, "An in-vitro study to compare the temperature rise in the pulp chamber by direct method using three different provisional restorative materials", J Indian Prosthodont Soc, 16, pp.36~41 (2016)
  14. Seelbach P, "Temperature rise on dentin caused by temporary crown and fixed partial denture materials: influencing factors", J Dent, 38, pp.964~973 (2010)
  15. Kulkarni MM, "Dimensional changes of alginate dental impression materials-An invitro study", J Clin Diagn Res, 9, pp.ZC98~ZC102 (2015)
  16. Al-Zarea BK, "Comparative analysis of dimensional precision of different silicone impression materials", J Contemp Dent Pract, 12, pp.208~215 (2011)
  17. Moulding MB, "Intrapulpal temperature during direct fabrication of provisional restorations", Int J Prosthodont, 3, pp.299~304 (1990)

관련 논문AI추천

Polymerization behavior and thermal characteristics of two new composites at five temperatures: refrigeration to preheatingAkbar Fazel, Marzieh Mirzaii, Mohmmad Erfan, Solmaz Eskandarion, Tahereh Sadat Jafarzadeh-Kashi, Vahid Rakhshan대한치과보철학회 · The Journal of Advanced of Prosthodontics2011 · 제3권 제4호Comparison of polymer-based temporary crown and fixed partial denture materials by diametral tensile strength김성훈, 양재호, 이재봉, 하승룡, 한중석대한치과보철학회 · The Journal of Advanced of Prosthodontics2010 · 제2권 제1호Temperature changes under demineralized dentin during polymerization of three resin-based restorative materials using QTH and LED unitsMaryam Khoroushi, Mohammad Atai, Mohammadreza Moharreri, Sayed-Mostafa Mousavinasab대한치과보존학회 · Restorative Dentistry and Endodontics2014 · 제39권 제3호Degree of conversion of bis-acrylic based provisional crown and fixed partial denture materials김성훈, David C. Watts대한치과보철학회 · 대한치과보철학회지2008 · 제46권 제6호Analysis of temperature change during polymerization according to resin thickness: an in vitro experimental study배꽃별, 오원만, 이빈나, 장훈상, 황윤찬, 황인남, Cho Young-Tae, Noh Eun-Young대한치과보존학회 · Restorative Dentistry and Endodontics2025 · 제50권 제4호Effect of solution temperature on the mechanical properties of dual-cure resin cements강은숙, 권용훈, 윤미정, 전영찬, 정창모, 허중보대한치과보철학회 · The Journal of Advanced of Prosthodontics2013 · 제5권 제2호

이 간행물의 다른 논문 (11건)