본문 바로가기
KERD
논문KCI 등재

Finite element analysis on stress distribution of maxillary implant-retained overdentures depending on the Bar attachment design and palatal coverage

1

조회

0

다운로드

2

인용

0

참고문헌

키워드

초록

PURPOSE. The purpose of this study was to determine the effect of anchorage systems and palatal coverage of denture base on load transfer in maxillary implant-retained overdenture. MATERIALS AND METHODS. Maxillary implant-retained overdentures with 4 implants placed in the anterior region of edentulous maxilla were converted into a 3-D numerical model, and stress distribution patterns in implant supporting bone in the case of unilateral vertical loading on maxillary right first molar were compared with each other depending on various types of anchorage system and palatal coverage extent of denture base using three-dimensional finite element analysis. RESULTS. In all experimental models, the highest stress was concentrated on the most distal implant and implant supporting bone on loaded side. The stress at the most distal implant-supporting bone was concentrated on the cortical bone. In all anchorage system without palatal coverage of denture base, higher stresses were concentrated on the most distal implant and implant supporting bone on loaded side. CONCLUSION. It could be suggested that when making maxillary implant retained overdenture, using Hader bar instead of milled bar and full palatal coverage rather than partial palatal coverage are more beneficial in distributing the stress that is applied on implant supporting bone. [J Adv Prosthodont 2016;8:85-93]

Abstract

PURPOSE. The purpose of this study was to determine the effect of anchorage systems and palatal coverage of denture base on load transfer in maxillary implant-retained overdenture. MATERIALS AND METHODS. Maxillary implant-retained overdentures with 4 implants placed in the anterior region of edentulous maxilla were converted into a 3-D numerical model, and stress distribution patterns in implant supporting bone in the case of unilateral vertical loading on maxillary right first molar were compared with each other depending on various types of anchorage system and palatal coverage extent of denture base using three-dimensional finite element analysis. RESULTS. In all experimental models, the highest stress was concentrated on the most distal implant and implant supporting bone on loaded side. The stress at the most distal implant-supporting bone was concentrated on the cortical bone. In all anchorage system without palatal coverage of denture base, higher stresses were concentrated on the most distal implant and implant supporting bone on loaded side. CONCLUSION. It could be suggested that when making maxillary implant retained overdenture, using Hader bar instead of milled bar and full palatal coverage rather than partial palatal coverage are more beneficial in distributing the stress that is applied on implant supporting bone. [J Adv Prosthodont 2016;8:85-93]

참고문헌 (40)

  1. Brånemark PI, "Osseointegrated implants in the treatment of the edentulous jaw. Experience from a 10-year period", Scand J Plast Reconstr Surg Suppl, 16, pp.1~132 (1977)
  2. Batenburg RH, "Treatment concept for mandibular overdentures supported by endosseous implants: a literature review", Int J Oral Maxillofac Implants, 13, pp.539~545 (1998)
  3. Engquist B, "A retrospective multicenter evaluation of osseointegrated implants supporting overdentures", Int J Oral Maxillofac Implants, 3, pp.129~134 (1988)
  4. Smedberg JI, "A clinical and radiological two-year follow-up study of maxillary overdentures on osseointegrated implants", Clin Oral Implants Res, 4, pp.39~46 (1993)
  5. Jemt T, "Failures and complications in 92 consecutively inserted overdentures supported by Brånemark implants in severely resorbed edentulous maxillae:a study from prosthetic treatment to first annual check-up", Int J Oral Maxillofac Implants, 7, pp.162~167 (1992)
  6. Hutton JE, "Factors related to success and failure rates at 3-year follow-up in a multicenter study of overdentures supported by Brånemark implants", Int J Oral Maxillofac Implants, 10, pp.33~42 (1995)
  7. Bergendal T, "Implant-supported overdentures: a longitudinal prospective study", Int J Oral Maxillofac Implants, 13, pp.253~262 (1998)
  8. Mericske-Stern RD, "Management of the edentulous patient", Clin Oral Implants Res, 11, pp.108~125 (2000)
  9. Palmqvist S, "Implant-supported maxillary overdentures: outcome in planned and emergency cases", Int J Oral Maxillofac Implants, 9, pp.184~190 (1994)
  10. 제홍지, "상악 임플란트 overdenture에서 anchorage system과 의치상 구개피개가 하중전달에 미치는 영향", 대한치과보철학회지, 42(4), pp.397~411 (2004), 대한치과보철학회
  11. Zitzmann NU, "Treatment plan for restoring the edentulous maxilla with implant-supported restorations:removable overdenture versus fixed partial denture design", J Prosthet Dent, 82, pp.188~196 (1999)
  12. 손차영, "상악 Overdenture에서 Bar Attachment설계에 따른 유지력 변화에 관한 연구", 대한치과보철학회지, 43(5), pp.650~661 (2005), 대한치과보철학회
  13. Moeller MS, "Rehabilitation of malpositioned implants with a CAD", CAM milled implant overdenture:a clinical report, 2011, pp.105, 143~146
  14. Spyropoulou PE, "Maxillary implant-supported bar overdenture and mandibular implant-retained fixed denture using CAD", CAM technology and 3-D design software: a clinical report, 2011, pp.105, 356~362
  15. 오상천, "상악 완전 무치악에서 Locator^Ⓡ attachment가 장착된 milled titanium bar를 이용한 임플란트 지지 피개의치: 증례 보고", 구강회복응용과학지, 27(2), pp.223~231 (2011), 대한턱관절교합학회
  16. 하헌석, "상악피개의치를 위한 임플랜트의 위치에 따른 응력분포에 대한 유한요소분석", 대한치과보철학회지, 46(2), pp.193~200 (2008), 대한치과보철학회
  17. Kydd WL, "The thickness measurement of masticatory mucosa in vivo", Int Dent J, 21, pp.430~441 (1971)
  18. Barão VA, "Finite element analysis to compare complete denture and implant-retained overdentures with different attachment systems", J Craniofac Surg, 20, pp.1066~1071 (2009)
  19. Tokuhisa M, "In vitro study of a mandibular implant overdenture retained with ball, magnet, or bar attachments: comparison of load transfer and denture stability", Int J Prosthodont, 16, pp.128~134 (2003)
  20. Federick DR, "Effects of overdenture retention designs and implant orientations on load transfer characteristics", J Prosthet Dent, 76, pp.624~632 (1996)
  21. Chun HJ, "Stress distributions in maxillary bone surrounding overdenture implants with different overdenture attachments", J Oral Rehabil, 32, pp.193~205 (2005)
  22. Barão VA, "Effect of different mucosa thickness and resiliency on stress distribution of implant-retained overdentures-2D FEA", Comput Methods Programs Biomed, 92, pp.213~223 (2008)
  23. Fanuscu MI, "Influence of attachment systems on load transfer of an implant-assisted maxillary overdenture", J Prosthodont, 13, pp.214~220 (2004)
  24. Hoshaw SJ, "Mechanical loading of Branemark implant affects interfacial bone resorption and remodeling", Int J Oral Maxillofac Implants, 9, pp.345~360 (1994)
  25. Jemt T, "Occlusal force and mandibular movements in patients with removable overdentures and fixed prostheses supported by implants in the maxilla", Int J Oral Maxillofac Implants, 8, pp.301~308 (1993)
  26. Mericske-Stern R, "In vivo force measurements on maxillary implants supporting a fixed prosthesis or an overdenture: a pilot study", J Prosthet Dent, 84, pp.535~547 (2000)
  27. Siegele D, "Numerical investigations of the influence of implant shape on stress distribution in the jaw bone", Int J Oral Maxillofac Implants, 4, pp.333~340 (1989)
  28. Skalak R, "Biomechanical considerations in osseointegrated prostheses", J Prosthet Dent, 49, pp.843~848 (1983)
  29. Sertgöz A, "Finite element analysis study of the effect of superstructure material on stress distribution in an implant-supported fixed prosthesis", Int J Prosthodont, 10, pp.19~27 (1997)
  30. Rieger MR, "A finite element survey of eleven endosseous implants", J Prosthet Dent, 63, pp.457~465 (1990)
  31. Clelland NL, "Threedimensional finite element stress analysis in and around the Screw-Vent implant", Int J Oral Maxillofac Implants, 6, pp.391~398 (1991)
  32. Borchers L, "Three-dimensional stress distribution around a dental implant at different stages of interface development", J Dent Res, 62, pp.155~159 (1983)
  33. Kim DW, "A study on the osseointegrated prosthesis using three dimensional finite element method", Korean Acad Prosthodont, 29, pp.167~212 (1991)
  34. Lee DO, "A study on the three dimensional finite element analysis of the stresses according to the curvature of arch and placement of implants", J Korean Acad Prosthodont, 33, pp.98~129 (1995)
  35. White SN, "Effect of cantilever length on stress transfer by implant-supported prostheses", J Prosthet Dent, 71, pp.493~499 (1994)
  36. Rangert B, "Forces and moments on Branemark implants", Int J Oral Maxillofac Implants, 4, pp.241~247 (1989)
  37. Engleman M, "Clinical decision making and treatment planning in osseointegration", pp.187~192 (1996), Quintessence;
  38. Lewis S, "Treatment of edentulous maxillae with osseointegrated implants", J Prosthet Dent, 68, pp.503~508 (1992)
  39. Ochiai KT, "Photoelastic analysis of the effect of palatal support on various implant-supported overdenture designs", J Prosthet Dent, 91, pp.421~427 (2004)
  40. Sakaguchi RL, "Nonlinear contact analysis of preload in dental implant screws", Int J Oral Maxillofac Implants, 10, pp.295~302 (1995)

관련 논문AI추천

Stress analysis of mandibular implant overdenture with locator and bar/clip attachment: Comparative study with differences in the denture base length권긍록, 노관태, 백장현, 유진숙, 이현종대한치과보철학회 · The Journal of Advanced of Prosthodontics2017 · 제9권 제3호Stress-strain distribution at bone-implant interface of two splinted overdenture systems using 3D finite element analysisMostafa Omran Hussein대한치과보철학회 · The Journal of Advanced of Prosthodontics2013 · 제5권 제3호Effect of implant- and occlusal load location on stress distribution in Locator attachments of mandibular overdenture. A finite element studyAngel Alvarez-Arenal, Aritza Brizuela-Velasco, Elena Martin-Fernandez, Hector deLlanos-Lanchares, Ignacio Gonzalez-Gonzalez, Joseba Ellacuria-Echebarria대한치과보철학회 · The Journal of Advanced of Prosthodontics2017 · 제9권 제5호Effects of overdenture attachment systems with different working principles on stress transmission: A three-dimensional finite element studyNurullah Turker, Ulviye Sebnem Buyukkaplan대한치과보철학회 · The Journal of Advanced of Prosthodontics2020 · 제12권 제6호상악 임플란트 피개의치에서 유지장치 종류와 구개 피개 유무에 따른 응력분포에 대한 유한 요소분석김경아, 박연희, 박종희, 서재민, 왕원곤, 이정진대한턱관절교합학회 · 구강회복응용과학지2020 · 제36권 제2호Evaluation of two interforaminal implants and implant-assisted removable dentures on stress distribution: an in vitro studyAltug Cilingir, Ergun Bozdag, Hakan Bilhan, Onur Geckili, Selda Arat Bilhan대한구강악안면외과학회 · 대한구강악안면외과학회지2019 · 제45권 제4호

이 간행물의 다른 논문 (11건)