Fracture resistance of CAD-CAM all-ceramic surveyed crowns with different occlusal rest seat designs
2
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Purpose. To investigate the fracture resistance of monolithic CAD-CAM allceramic surveyed crowns with two different occlusal rest seat designs. Materials and Methods. Two maxillary first premolar were prepared for all-ceramic surveyed crowns with wide (2/3rd of buccolingual width of an unprepared tooth) or narrow (1/3rd of buccolingual width of an unprepared tooth) disto-occlusal rest seat (ORS) designs. Eighty monolithic CAD-CAM all-ceramic surveyed crowns were prepared and divided into 4 groups - Group CR, Composite resin material as a control; Group LDS, Lithium disilicate based material; Group ZIPS, zirconiamaterial (IPS ZirCAD); and Group ZLHT, zirconia- material (CeramillZolidht+). Crowns were cemented on an epoxy resin die with adhesive resin cement. The fracture resistance of crowns was tested with the universal machine. Univariate regression analysis was used. Results. The mean ± standard deviation of maximum failure force values varied from 3476.10 ± 285.97 N for the narrow ORS subgroup of group ZIPS to 687.89 ± 167.63 N for the wide ORS subgroup of group CR. The mean ± standard deviation of maximum force was 1075 ± 77.0 N for group CR, 1309.3 ± 283.9 N for group LDS, 3476.1 ± 285.97 N for group ZIPS, and 2666.7 ± 228.21 N for group ZLHT, with narrow occlusal rest seat design. The results of the intergroup comparison showed significant differences in fracture strength with various material groups and occlusal rest seat designs (P <.001). Conclusion. The zirconia-based all-ceramic surveyed crowns fractured at more than double the load of Lithium disilicate based crowns. The crowns with narrow base occlusal rest seat design had statistically significantly higher fracture resistance than surveyed crowns with wide occlusal rest seat design. The use of narrow occlusal rest seat design in CAD-CAM all ceramic surveyed crowns provides higher fracture resistance, and therefore narrow occlusal rest design can be used for providing esthetics with high strength.
Abstract
Purpose. To investigate the fracture resistance of monolithic CAD-CAM allceramic surveyed crowns with two different occlusal rest seat designs. Materials and Methods. Two maxillary first premolar were prepared for all-ceramic surveyed crowns with wide (2/3rd of buccolingual width of an unprepared tooth) or narrow (1/3rd of buccolingual width of an unprepared tooth) disto-occlusal rest seat (ORS) designs. Eighty monolithic CAD-CAM all-ceramic surveyed crowns were prepared and divided into 4 groups - Group CR, Composite resin material as a control; Group LDS, Lithium disilicate based material; Group ZIPS, zirconiamaterial (IPS ZirCAD); and Group ZLHT, zirconia- material (CeramillZolidht+). Crowns were cemented on an epoxy resin die with adhesive resin cement. The fracture resistance of crowns was tested with the universal machine. Univariate regression analysis was used. Results. The mean ± standard deviation of maximum failure force values varied from 3476.10 ± 285.97 N for the narrow ORS subgroup of group ZIPS to 687.89 ± 167.63 N for the wide ORS subgroup of group CR. The mean ± standard deviation of maximum force was 1075 ± 77.0 N for group CR, 1309.3 ± 283.9 N for group LDS, 3476.1 ± 285.97 N for group ZIPS, and 2666.7 ± 228.21 N for group ZLHT, with narrow occlusal rest seat design. The results of the intergroup comparison showed significant differences in fracture strength with various material groups and occlusal rest seat designs (P <.001). Conclusion. The zirconia-based all-ceramic surveyed crowns fractured at more than double the load of Lithium disilicate based crowns. The crowns with narrow base occlusal rest seat design had statistically significantly higher fracture resistance than surveyed crowns with wide occlusal rest seat design. The use of narrow occlusal rest seat design in CAD-CAM all ceramic surveyed crowns provides higher fracture resistance, and therefore narrow occlusal rest design can be used for providing esthetics with high strength.
참고문헌 (37)
- Freire Y, "The marginal fit of CAD", CAM monolithic ceramic and metal-ceramic crowns, 2019, pp.28, 299~304
- Rodríguez V, "Fracture load before and after veneering zirconia posterior fixed dental prostheses", J Prosthodont, 25, pp.550~556 (2016)
- Pelaez J, "A four-year prospective clinical evaluation of zirconia and metal-ceramic posterior fixed dental prostheses", Int J Prosthodont, 25, pp.451~458 (2012)
- Martínez-Rus F, "Evaluation of the absolute marginal discrepancy of zirconia-based ceramic copings", J Prosthet Dent, 105, pp.108~114 (2011)
- Shareen H Elshiyab, "Fracture resistance of implantsupported monolithic crowns cemented to zirconia hybridabutments: zirconia-based crowns vs. lithium disilicate crowns", The Journal of Advanced of Prosthodontics, 10(1), pp.65~72 (2018), 대한치과보철학회[DOI]
- Carracho JF, "Removable partial denture abutments restored with all-ceramic surveyed crowns", Quintessence Int, 37, pp.283~288 (2006)
- Manchester JA, "F racture resistance of cingulum rest seats in CAD-CAM tooth-colored crowns for removable partial enture abutments", J Prosthet Dent, 121, pp.828~835 (2019)
- Sattar J, "A comparison of fracture strength among different brands of translucent zirconia crown restorations", J Bio Agriculture Healthc, 6, pp.111~119 (2016)
- Gouveia DNM, "A fully digital approach to fabricating a CAD-CAM ceramic crown to fit an existing removable partial denture", J Prosthet Dent, 121, pp.571~575 (2019)
- Bethke A, "Fracture resistance of zirconia oral implants in vitro: a systematic review and meta-analysis", Materials(Basel), 13, pp.562~ (2020)
- Shahrbaf S, "Fracture strength of machined ceramic crowns as a function of tooth preparation design and the elastic modulus of the cement", Dent Mater, 30, pp.234~241 (2014)
- Sagsoz NP, "Evaluation of the fracture resistance of computer-aided design", computer-aided manufacturing monolithic crowns prepared in different cement thicknesses, 2018, pp.21, 417~422
- Pihlaja J, "Veneered zirconia crowns as abutment teeth for partial removable dental prostheses : a clinical 4-year retrospective study", J Prosthet Dent, 114, pp.633~636 (2015)
- Yoon TH, "The fabrication of a CAD", CAM ceramic crown to fit an existing partial removable dental prosthesis : a clinical report, 2012, pp.108, 143~146
- Miura S, "A possible risk of CAD", CAM-produced composite resin premolar crowns on a removable partial denture abutment tooth : a 3-year retrospective cohort study, 2019, pp.63, 78~84
- Lan TH, "Fracture resistance of monolithic zirconia crowns in implant prostheses in patients with bruxism", Materials(Basel), 12, pp.1623~ (2019)
- Sun T, "Load-bearing capacity and the recommended thickness of dental monolithic zirconia single crowns", J Mech Behav Biomed Mater, 35, pp.93~101 (2014)
- Glann G, "Mouth preparation for removable partial dentures", J Prosthet Dent, 10, pp.698~706 (1960)
- Perry C, "A philosophy of partial denture design", J Prosthet Dent, 6, pp.775~784 (1956)
- Miller E, "Removable partial prosthodontics" (1981), Williams and Wilkins
- Culwick PF, "The size of occlusal rest seats prepared for removable partial dentures", Br Dent J, 189, pp.318~322 (2000)
- Attia A, "Fracture load of composite resin and feldspathic all-ceramic CAD", CAM crowns, 2006, pp.95, 117~123
- Sampaio-Fernandes MA, "Evaluation of occlusal rest seats with 3D technology in dental education", J Dent Educ, 79, pp.166~176 (2015)
- Chung SM, "Elastic modulus of resin-based dental restorative materials : a microindentation approach", J Biomed Mater Res B Appl Biomater, 72, pp.246~253 (2005)
- Martínez-Rus F, "Fracture resistance of crowns cemented on titanium and zirconia implant abutments : a comparison of monolithic versus manually veneered all-ceramic systems", Int J Oral Maxillofac Implants, 27, pp.1448~1455 (2012)
- Brijawi A, "Effect of different core design made of computer-aided design", computer-aided manufacturing system and veneering technique on the fracture resistance of zirconia crowns : a laboratory study, 2019, pp.22, 59~63
- Rice JA, "Tooth preparation for rest seats for cobalt-chromium removable partial dentures completed by general dental practitioners", J Oral Rehabil, 38, pp.72~78 (2011)
- Sato Y, "The effect of occlusal rest size and shape on yield strength", J Prosthet Dent, 89, pp.503~507 (2003)
- Nakamura K, "Fracture resistance of monolithic zirconia molar crowns with reduced thickness", Acta Odontol Scand, 73, pp.602~608 (2015)
- Kim JH, "Fracture load of zirconia crowns according to the thickness and marginal design of coping", J Prosthet Dent, 108, pp.96~101 (2012)
- Vagkopoulou T, "Zirconia in dentistry: part 1. discovering the nature of an upcoming bioceramic", Eur J Esthet Dent, 4, pp.130~151 (2009)
- Denry I, "State of the art of zirconia for dental applications", Dent Mater, 24, pp.299~307 (2008)
- Anupama PD, "Methods to enhance esthetics in removable prosthesis-a narrative review", Int J Clin Dent, 13, pp.317~328 (2020)
- Kashkari A, "Fracture analysis of monolithic CAD-CAM crowns", J Esthet Restor Dent, 31, pp.346~352 (2019)
- Okada R, "Fracture strength testing of crowns made of CAD", CAM composite resins, 2018, pp.62, 287~292
- Ohlmann B, "Optimizing preparation design for metal-free composite resin crowns", J Prosthet Dent, 100, pp.211~219 (2008)
- Kirsch C, "Trueness of four different milling procedures used in dental CAD", CAM systems, 2017, pp.21, 551~558
