Effect of different lateral occlusion schemes on peri-implant strain: A laboratory study

2

조회

0

다운로드

2

인용

0

참고문헌

키워드

초록

PURPOSE. This study aims to investigate the effects of four different lateral occlusion schemes and different excursions on peri-implant strains of a maxillary canine implant. MATERIALS AND METHODS. Four metal crowns with different occlusion schemes were attached to an implant in the maxillary canine region of a resin model. The included schemes were canine-guided (CG) occlusion, group function (GF) occlusion, long centric (LC) occlusion, and implant-protected (IP) occlusion. Each crown was loaded in three sites that correspond to maximal intercuspation (MI), 1 mm excursion, and 2 mm excursion. A load of 140 N was applied on each site and was repeated 10 times. The peri-implant strain was recorded by a rosette strain gauge that was attached on the resin model buccal to the implant. For each loading condition, the maximum shear strain value was calculated. RESULTS. The different schemes and excursive positions had impact on the peri-implant strains. At MIand 1 mm positions, the GF had the least strains, followed by IP, CG, and LC. At 2 mm, the least strains were associated with GF, followed by CG, LC, and IP. However, regardless of the occlusion scheme, as the excursion increases, a linear increase of peri-implant strains was detected. CONCLUSION. The peri-implant strain is susceptible to occlusal factors. The eccentric location appears to be more influential on peri-implant strains than the occlusion scheme. Therefore, adopting an occlusion scheme that can reduce the occurrence of occlusal contacts laterally may be beneficial in reducing peri-implant strains.

Abstract

PURPOSE. This study aims to investigate the effects of four different lateral occlusion schemes and different excursions on peri-implant strains of a maxillary canine implant. MATERIALS AND METHODS. Four metal crowns with different occlusion schemes were attached to an implant in the maxillary canine region of a resin model. The included schemes were canine-guided (CG) occlusion, group function (GF) occlusion, long centric (LC) occlusion, and implant-protected (IP) occlusion. Each crown was loaded in three sites that correspond to maximal intercuspation (MI), 1 mm excursion, and 2 mm excursion. A load of 140 N was applied on each site and was repeated 10 times. The peri-implant strain was recorded by a rosette strain gauge that was attached on the resin model buccal to the implant. For each loading condition, the maximum shear strain value was calculated. RESULTS. The different schemes and excursive positions had impact on the peri-implant strains. At MIand 1 mm positions, the GF had the least strains, followed by IP, CG, and LC. At 2 mm, the least strains were associated with GF, followed by CG, LC, and IP. However, regardless of the occlusion scheme, as the excursion increases, a linear increase of peri-implant strains was detected. CONCLUSION. The peri-implant strain is susceptible to occlusal factors. The eccentric location appears to be more influential on peri-implant strains than the occlusion scheme. Therefore, adopting an occlusion scheme that can reduce the occurrence of occlusal contacts laterally may be beneficial in reducing peri-implant strains.

참고문헌 (24)

  1. Kim Y, "Occlusal considerations in implant therapy: clinical guidelines with biomechanical rationale", Clin Oral Implants Res, 16, pp.26~35 (2005)
  2. Chen YY, "Implant occlusion: biomechanical considerations for implant-supported prostheses", J Dent Sci, 3, pp.65~74 (2008)
  3. Abichandani SJ, "Implant protected occlusion: A comprehensive review", Eur J Prosthodont, 1, pp.29~36 (2013)
  4. Thornton LJ, "Anterior guidance: group function", canine guidance. A literature review, 1990, pp.64, 479~482
  5. Belser UC, "The influence of altered workingside occlusal guidance on masticatory muscles and related jaw movement", J Prosthet Dent, 53, pp.406~413 (1985)
  6. Okano N, "The influence of altered occlusal guidance on condylar displacement", J Oral Rehabil, 29, pp.1091~1098 (2002)
  7. Ogawa T, "The relationship between inclination of the occlusal plane and jaw closing path", J Prosthet Dent, 76, pp.576~580 (1996)
  8. Ogawa T, "Characteristics of masticatory movement in relation to inclination of occlusal plane", J Oral Rehabil, 24, pp.652~657 (1997)
  9. "The glossary of prosthodontic terms", J Prosthet Dent, 94, pp.10~92 (2005)
  10. Rinchuse DJ, "A contemporary and evidence-based view of canine protected occlusion", Am J Orthod Dentofacial Orthop, 132, pp.90~102 (2007)
  11. Abduo J, "Impact of lateral occlusion schemes: A systematic review", J Prosthet Dent, 114, pp.193~204 (2015)
  12. Abduo J, "Lateral occlusion schemes in natural and minimally restored permanent dentition: a systematic review", J Oral Rehabil, 40, pp.788~802 (2013)
  13. Carlsson GE, "Dental occlusion: modern concepts and their application in implant prosthodontics", Odontology, 97, pp.8~17 (2009)
  14. Stanford CM, "Toward an understanding of implant occlusion and strain adaptive bone modeling and remodeling", J Prosthet Dent, 81, pp.553~561 (1999)
  15. Weinberg LA, "Reduction of implant loading using a modified centric occlusal anatomy", Int J Prosthodont, 11, pp.55~69 (1998)
  16. Weinberg LA, "Therapeutic biomechanics concepts and clinical procedures to reduce implant loading. Part I", J Oral Implantol, 27, pp.293~301 (2001)
  17. Jemt T, "Changes in chewing patterns of patients with complete dentures after placement of osseointegrated implants in the mandible", J Prosthet Dent, 53, pp.578~583 (1985)
  18. Kinsel RP, "Retrospective analysis of porcelain failures of metal ceramic crowns and fixed partial dentures supported by 729 implants in 152 patients: patient-specific and implantspecific predictors of ceramic failure", J Prosthet Dent, 101, pp.388~394 (2009)
  19. Rungsiyakull P, "Loading of a single implant in simulated bone", Int J Prosthodont, 24, pp.140~143 (2011)
  20. Taylor TD, "Prosthodontic considerations", Clin Oral Implants Res, 11, pp.101~107 (2000)
  21. Stanford CM, "Issues and considerations in dental implant occlusion:what do we know, and what do we need to find out?", J Calif Dent Assoc, 33, pp.329~336 (2005)
  22. Suit SR, "Study of gliding tooth contacts during mastication", J Periodontol, 47, pp.331~334 (1976)
  23. Woda A, "Nonfunctional and functional occlusal contacts: a review of the literature", J Prosthet Dent, 42, pp.335~341 (1979)
  24. Morneburg TR, "In vivo forces on implants influenced by occlusal scheme and food consistency", Int J Prosthodont, 16, pp.481~486 (2003)

관련 논문AI추천

Strain of implants depending on occlusion types in mandibular implant-supported fixed prostheses곽재영, 김성균, 손병섭, 이수영, 허성주대한치과보철학회 · The Journal of Advanced of Prosthodontics2011 · 제3권 제1호An evaluation of the stress effect of different occlusion concepts on hybrid abutment and implant supported monolithic zirconia fixed prosthesis: A finite element analysisAli Riza Tuncdemir, Nilgün Gulbahce Yesilyurt대한치과보철학회 · The Journal of Advanced of Prosthodontics2021 · 제13권 제4호Comparative evaluation of peri-implant stress distribution in implant protected occlusion and cuspally loaded occlusion on a 3 unit implant supported fixed partial denture: A 3D finite element analysis studyParamba Hitendrabhai Acharya, Sareen Subhash Duseja, Vilas Valjibhai Patel, Vishal Rajendrabhai Chauhan대한치과보철학회 · The Journal of Advanced of Prosthodontics2021 · 제13권 제2호Impact of type and position of abutment connection on microstrain distribution: an in vitro studyBasel Mahardawi, Chamaiporn Sukjamsri, Jekita Siripru, Napapa Aimjirakul, Usanee Puengpaiboon대한치과보철학회 · The Journal of Advanced of Prosthodontics2024 · 제16권 제5호Occlusion for implant-supported fixed dental prostheses in partially edentulous patients: a literature review and current conceptsCortino Sukotjo, Judy Chia-Chun Yuan대한치주과학회 · Journal of Periodontal & Implant Science2013 · 제43권 제2호Strains around distally inclined implants retaining mandibular overdentures with Locator attachments: an in vitro studyAhmed Samir Khirallah, Fathi Abo Setta, Moustafa Abdou Elsyad대한치과보철학회 · The Journal of Advanced of Prosthodontics2016 · 제8권 제2호