Comparative finite element analysis of mandibular posterior single zirconia and titanium implants: a 3-dimensional finite element analysis
2
조회
0
다운로드
1
인용
0
참고문헌
키워드
초록
PURPOSE. Zirconia has exceptional biocompatibility and good mechanical properties in clinical situations. However, finite element analysis (FEA) studies on the biomechanical stability of two-piece zirconia implant systems are limited. Therefore, the aim of this study was to compare the biomechanical properties of the two-piece zirconia and titanium implants using FEA. MATERIALS AND METHODS. Two groups of finite element (FE) models, the zirconia (Zircon) and titanium (Titan) models, were generated for the exam. Oblique (175 N) and vertical (175 N) loads were applied to the FE model generated for FEA simulation, and the stress levels and distributions were investigated. RESULTS. In oblique loading, von Mises stress values were the highest in the abutment of the Zircon model. The von Mises stress values of the Titan model for the abutment screw and implant fixture were slightly higher than those of the Zircon model. Minimum principal stress in the cortical bone was higher in the Titan model than Zircon model under oblique and vertical loading. Under both vertical and oblique loads, stress concentrations in the implant components and bone occurred in the same area. Because the material itself has high stiffness and elastic modulus, the Zircon model exhibited a higher von Mises stress value in the abutments than the Titan model, but at a level lower than the fracture strength of the material. CONCLUSION. Owing to the good esthetics and stress controllability of the Zircon model, it can be considered for clinical use.
Abstract
PURPOSE. Zirconia has exceptional biocompatibility and good mechanical properties in clinical situations. However, finite element analysis (FEA) studies on the biomechanical stability of two-piece zirconia implant systems are limited. Therefore, the aim of this study was to compare the biomechanical properties of the two-piece zirconia and titanium implants using FEA. MATERIALS AND METHODS. Two groups of finite element (FE) models, the zirconia (Zircon) and titanium (Titan) models, were generated for the exam. Oblique (175 N) and vertical (175 N) loads were applied to the FE model generated for FEA simulation, and the stress levels and distributions were investigated. RESULTS. In oblique loading, von Mises stress values were the highest in the abutment of the Zircon model. The von Mises stress values of the Titan model for the abutment screw and implant fixture were slightly higher than those of the Zircon model. Minimum principal stress in the cortical bone was higher in the Titan model than Zircon model under oblique and vertical loading. Under both vertical and oblique loads, stress concentrations in the implant components and bone occurred in the same area. Because the material itself has high stiffness and elastic modulus, the Zircon model exhibited a higher von Mises stress value in the abutments than the Titan model, but at a level lower than the fracture strength of the material. CONCLUSION. Owing to the good esthetics and stress controllability of the Zircon model, it can be considered for clinical use.
참고문헌 (46)
- Çaglar A, "Three-dimensional finite element analysis of titanium and yttrium-stabilized zirconium dioxide abutments and implants", Int J Oral Maxillofac Implants, 26, pp.961~969 (2011)
- Cionca N, "Zirconia dental implants:where are we now, and where are we heading?", Periodontol 2000, 73, pp.241~258 (2017)
- Buser D, "10-year survival and success rates of 511 titanium implants with a sandblasted and acid-etched surface : a retrospective study in 303 partially edentulous patients", Clin Implant Dent Relat Res, 14, pp.839~851 (2012)
- Bidra AS, "Clinical outcomes of implant abutments in the anterior region : a systematic review", J Esthet Restor Dent, 25, pp.159~176 (2013)
- Thoma DS, "Effects of soft tissue augmentation procedures on peri-implant health or disease : A systematic review and meta-analysis", Clin Oral Implants Res, 29, pp.32~49 (2018)
- Siddiqi A, "Titanium allergy: could it affect dental implant integration?", Clin Oral Implants Res, 22, pp.673~680 (2011)
- Sivaraman K, "Is zirconia a viable alternative to titanium for oral implant? A critical review", J Prosthodont Res, 62, pp.121~133 (2018)
- Becker J, "Clinical performance of two-piece zirconia implants in the posterior mandible and maxilla : a prospective cohort study over 2 years", Clin Oral Implants Res, 28, pp.29~35 (2017)
- Depprich R, "Current findings regarding zirconia implants", Clin Implant Dent Relat Res, 16, pp.124~137 (2014)
- Denry I, "State of the art of zirconia for dental applications", Dent Mater, 24, pp.299~307 (2008)
- Al-Amleh B, "Clinical trials in zirconia : a systematic review", J Oral Rehabil, 37, pp.641~652 (2010)
- Gautam C, "Zir-conia based dental ceramics: structure, mechanical properties, biocompatibility and applications", Dalton Trans, 45, pp.19194~19215 (2016)
- Joos M, "Stability of screw-retention in two-piece zirconia implants : An in vitro study", Clin Oral Implants Res, 31, pp.607~614 (2020)
- Talmazov G, "Finite element analysis of a one-piece zirconia implant in anterior single tooth implant applications", PLoS One, 15, pp.e0229360~ (2020)
- Liñares A, "Histological assessment of hard and soft tissues surrounding a novel ceramic implant : a pilot study in the minipig", J Clin Periodontol, 43, pp.538~546 (2016)
- Roehling S, "In vitro biofilm formation on titanium and zirconia implant surfaces", J Periodontol, 88, pp.298~307 (2017)
- Janner SFM, "Bone response to functionally loaded, two-piece zirconia implants:A preclinical histometric study", Clin Oral Implants Res, 29, pp.277~289 (2018)
- Balmer M, "Three-year analysis of zirconia implants used for single-tooth replacement and three-unit fixed dental prostheses : A prospective multicenter study", Clin Oral Implants Res, 29, pp.290~299 (2018)
- Bormann KH, "A prospective clinical study to evaluate the performance of zirconium dioxide dental implants in single-tooth edentulous area : 3-year follow-up", BMC Oral Health, 18, pp.181~ (2018)
- Cionca N, "Two-piece zirconia implants supporting all-ceramic crowns : a prospective clinical study", Clin Oral Implants Res, 26, pp.413~418 (2015)
- Lopez CAV, "Three-dimensional finite element analysis of stress distribution in zirconia and titanium dental implants", J Oral Implantol, 44, pp.409~415 (2018)
- Lin YT, "Clinical evaluation of two-piece zirconia abutments with bonded titanium inserts for implant-supported restorations", J Prosthet Dent, 123, pp.449~454 (2020)
- Brandão de Holanda KA, "Biomechanical evaluation of anterior implants associated with titanium and zirconia abutments and monotype zirconia implants", J Prosthodont Res, 65, pp.73~77 (2021)
- de Matos JDM, "Biomechanical evaluation of 3-unit fixed partial dentures on monotype and two-piece zirconia dental implants", Comput Methods Biomech Biomed Engin, pp.1~8 (2021)
- Bulaqi HA, "Effect of increased crown height on stress distribution in short dental implant components and their surrounding bone : A finite element analysis", J Prosthet Dent, 113, pp.548~557 (2015)
- Bankoğlu Güngör M, "Evaluation of stress distributions occurring on zirconia and titanium implant-supported prostheses : A three-dimensional finite element analysis", J Prosthet Dent, 116, pp.346~355 (2016)
- Kaleli N, "Effect of different restorative crown and customized abutment materials on stress distribution in single implants and peripheral bone : A three-dimensional finite element analysis study", J Prosthet Dent, 119, pp.437~445 (2018)
- Sannino G, "Influence of finish line in the distribution of stress trough an all ceramic implant-supported crown: A 3D finite element analysis", Oral Implantol(Rome), 2, pp.14~27 (2009)
- Zhang G, "A three-dimensional finite element study on the biomechanical simulation of various structured dental implants and their surrounding bone tissues", Int J Dent, 2016, pp.4867402~ (2016)
- Kim WH, "Optimized dental implant fixture design for the desirable stress distribution in the surrounding bone region: a biomechanical analysis", Materials(Basel), 12, pp.2749~ (2019)
- 이현종, "Effects of cementless fixation of implant prosthesis: A finite element study", The Journal of Advanced of Prosthodontics, 11(6), pp.341~349 (2019), 대한치과보철학회[DOI]
- Lin D, "Dental implant induced bone remodeling and associated algorithms", J Mech Behav Biomed Mater, 2, pp.410~432 (2009)
- Geng JP, "Application of finite element analysis in implant dentistry : a review of the literature", J Prosthet Dent, 85, pp.585~598 (2001)
- Bal BT, "Finite element analysis of stress distribution with splinted and nonsplinted maxillary anterior fixed prostheses supported by zirconia or titanium implants", Int J Oral Maxillofac Implants, 28, pp.e27~e38 (2013)
- Caglar A, "Evaluation of stresses occurring on three different zirconia dental implants : three-dimensional finite element analysis", Int J Oral Maxillofac Implants, 25, pp.95~103 (2010)
- Akça K, "Finite element stress analysis of the effect of short implant usage in place of cantilever extensions in mandibular posterior edentulism", J Oral Rehabil, 29, pp.350~356 (2002)
- Nakamura K, "Zirconia as a dental implant abutment material : a systematic review", Int J Prosthodont, 23, pp.299~309 (2010)
- Kim JS, "In vitro assessment of three types of zirconia implant abutments under static load", J Prosthet Dent, 109, pp.255~263 (2013)
- Reilly DT, "The elastic and ultimate properties of compact bone tissue", J Biomech, 8, pp.393~405 (1975)
- Pérez-Pevida E, "Biomechanical consequences of the elastic properties of dental implant alloys on the supporting bone : finite element analysis", Biomed Res Int, 2016, pp.1850401~ (2016)
- Glauser R, "Experimental zirconia abutments for implant-supported single-tooth restorations in esthetically demanding regions : 4-year results of a prospective clinical study", Int J Prosthodont, 17, pp.285~290 (2004)
- Yildirim M, "In vivo fracture resistance of implant-supported all-ceramic restorations", J Prosthet Dent, 90, pp.325~331 (2003)
- El-Anwar MI, "New dental implant selection criterion based on implant design", Eur J Dent, 11, pp.186~191 (2017)
- Bryington M, "Patient selection and treatment planning for implant restorations", Dent Clin North Am, 58, pp.193~206 (2014)
- Brodt MD, "Mechanical behavior of human morselized cancellous bone in triaxial compression testing", J Orthop Res, 16, pp.43~49 (1998)
- Webber LP, "Will zirconia implants replace titanium implants?", Appl Sci, 11, pp.6776~ (2021)
