The impact of frenulum height on strains in maxillary denture bases
2
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
PURPOSE. The midline fracture of maxillary complete dentures is a frequently encountered complication. The purpose of this study was to assess the effect of frenulum height on midline strains of maxillary complete dentures. MATERIALS AND METHODS. A removable maxillary complete denture was fabricated and duplicated seven times. Four different labial frenulum heights were tested for stresses occurring on the palatal cameo surface. The strains were measured with strain gauges placed on 5 different locations and the stresses were calculated. To mimic occlusal forces bilaterally 100 N of load was applied from the premolar and molar region. RESULTS. A statistically significant association between the height of the labial frenulum and the calculated stresses and strains was shown (P<.05) predominantly on the midline and especially on the incisive papilla. The results showed that stress on the anterior midline of the maxillary complete denture increases with a higher labial frenulum. CONCLUSION. Within the limitations of this in vitro study, it can be concluded that the stress on the anterior midline of the maxillary complete denture increases with a higher labial frenulum. Surgical or mechanical precautions should be taken to prevent short-term failure of maxillary complete dentures due to stress concentration and low cycle fatigue tendency at the labial frenulum region.
Abstract
PURPOSE. The midline fracture of maxillary complete dentures is a frequently encountered complication. The purpose of this study was to assess the effect of frenulum height on midline strains of maxillary complete dentures. MATERIALS AND METHODS. A removable maxillary complete denture was fabricated and duplicated seven times. Four different labial frenulum heights were tested for stresses occurring on the palatal cameo surface. The strains were measured with strain gauges placed on 5 different locations and the stresses were calculated. To mimic occlusal forces bilaterally 100 N of load was applied from the premolar and molar region. RESULTS. A statistically significant association between the height of the labial frenulum and the calculated stresses and strains was shown (P<.05) predominantly on the midline and especially on the incisive papilla. The results showed that stress on the anterior midline of the maxillary complete denture increases with a higher labial frenulum. CONCLUSION. Within the limitations of this in vitro study, it can be concluded that the stress on the anterior midline of the maxillary complete denture increases with a higher labial frenulum. Surgical or mechanical precautions should be taken to prevent short-term failure of maxillary complete dentures due to stress concentration and low cycle fatigue tendency at the labial frenulum region.
참고문헌 (30)
- Prombonas AE, "Comparison of the midline stress fields in maxillary and mandibular complete dentures: a pilot study", J Prosthet Dent, 95, pp.63~70 (2006)
- Beyli MS, "An analysis of causes of fracture of acrylic resin dentures", J Prosthet Dent, 46, pp.238~241 (1981)
- Darbar UR, "Denture fracture-a survey", Br Dent J, 176, pp.342~345 (1994)
- Hargreaves AS, "The prevalence of fractured dentures. A survey", Br Dent J, 126, pp.451~455 (1969)
- Karacaer O, "Reinforcement of maxillary dentures with silane-treated ultra high modulus polyethylene fibers", J Oral Sci, 43, pp.103~107 (2001)
- Kim SH, "The effect of reinforcement with woven E-glass fibers on the impact strength of complete dentures fabricated with high-impact acrylic resin", J Prosthet Dent, 91, pp.274~280 (2004)
- Kelly E, "Fatigue failure in denture base polymers", J Prosthet Dent, 21, pp.257~266 (1969)
- Craig RG, "Three-dimensional photoelastic stress analysis of maxillary complete dentures", J Prosthet Dent, 31, pp.122~129 (1974)
- Prombonas A, "Effects of the position of artificial teeth and load levels on stress in the complete maxillary denture", J Prosthet Dent, 88, pp.415~422 (2002)
- Dirtoft BI, "Using holography for measurement of in vivo deformation in a complete maxillary denture", J Prosthet Dent, 54, pp.843~846 (1985)
- Cheng YY, "Strain analysis of maxillary complete denture with three-dimensional finite element method", J Prosthet Dent, 103, pp.309~318 (2010)
- Rees JS, "Finite element analysis of the stress-concentrating effect of fraenal notches in complete dentures", Int J Prosthodont, 3, pp.238~240 (1990)
- Ateş M, "The effect of occlusal contact localization on the stress distribution in complete maxillary denture", J Oral Rehabil, 33, pp.509~513 (2006)
- Jagger DC, "The reinforcement of dentures", J Oral Rehabil, 26, pp.185~194 (1999)
- Vallittu PK, "Evaluation of damage to removable dentures in two cities in Finland", Acta Odontol Scand, 51, pp.363~369 (1993)
- Nejatidanesh F, "Effect of labial frenum notch size and palatal vault depth on stress concentration in a maxillary complete denture: a finite element study", J Contemp Dent Pract, 10, pp.59~66 (2009)
- Lindquist TJ, "Denture duplication technique with alternative materials", J Prosthet Dent, 77, pp.97~98 (1997)
- Mutlu G, "A history of denture base materials", Quintessence Dent Technol Yearbook, 13, pp.145~151 (1989)
- Schneider RL, "Diagnosing functional complete denture fractures", J Prosthet Dent, 54, pp.809~814 (1985)
- Akça K, "A photoelastic and strain-gauge analysis of interface force transmission of internal-cone implants", Int J Periodontics Restorative Dent, 28, pp.391~399 (2008)
- Eser A, "Nonlinear finite element analysis versus ex vivo strain gauge measurements on immediately loaded implants", Int J Oral Maxillofac Implants, 24, pp.439~446 (2009)
- Hirajima Y, "Influence of a denture strengthener on the deformation of a maxillary complete denture", Dent Mater J, 28, pp.507~512 (2009)
- Lambrecht JR, "A functional stress analysis of the maxillary complete denture base", J Prosthet Dent, 12, pp.865~872 (1962)
- Matsukawa S, "Development of high-toughness resin for dental applications", Dent Mater, 10, pp.343~346 (1994)
- Uzun G, "Effect of five woven fiber reinforcements on the impact and transverse strength of a denture base resin", J Prosthet Dent, 81, pp.616~620 (1999)
- Vallittu PK, "Flexural properties of acrylic resin polymers reinforced with unidirectional and woven glass fibers", J Prosthet Dent, 81, pp.318~326 (1999)
- Vallittu PK, "Dimensional accuracy and stability of polymethyl methacrylate reinforced with metal wire or with continuous glass fiber", J Prosthet Dent, 75, pp.617~621 (1996)
- Rached RN, "Dynamic and static strength of an implant-supported overdenture model reinforced with metal and nonmetal strengtheners", J Prosthet Dent, 106, pp.297~304 (2011)
- Kanie T, "Mechanical properties of reinforced denture base resin: the effect of position and the number of woven glass fibers", Dent Mater J, 21, pp.261~269 (2002)
- Goguţă LM, "Glass fibre reinforced acrylic resin complete dentures: a5-year clinical study", Gerodontology, 29, pp.64~69 (2012)
