Cobalt-Chromium (Co-Cr) alloys are classified as predominantly base-metal alloys and are widely known for their biomedical applications in the orthopedic and dental fields. In dentistry, Co-Cr alloys are commonly used for the fabrication of metallic frameworks of removable partial dentures and recently have been used as metallic substructures for the fabrication of porcelain-fused-to-metal restorations and implant frameworks. The increased worldwide interest in utilizing Co-Cr alloys for dental applications is related to their low cost and adequate physico-mechanical properties. Additionally, among base-metal alloys, Co-Cr alloys are used more frequently in many countries to replace Nickel-Chromium (Ni-Cr) alloys. This is mainly due to the increased concern regarding the toxic effects of Ni on the human body when alloys containing Ni are exposed to the oral cavity. This review article describes dental applications, metallurgical characterization, and physico-mechanical properties of Co-Cr alloys and also addresses their clinical and laboratory behavior in relation to those properties.

Abstract

Cobalt-Chromium (Co-Cr) alloys are classified as predominantly base-metal alloys and are widely known for their biomedical applications in the orthopedic and dental fields. In dentistry, Co-Cr alloys are commonly used for the fabrication of metallic frameworks of removable partial dentures and recently have been used as metallic substructures for the fabrication of porcelain-fused-to-metal restorations and implant frameworks. The increased worldwide interest in utilizing Co-Cr alloys for dental applications is related to their low cost and adequate physico-mechanical properties. Additionally, among base-metal alloys, Co-Cr alloys are used more frequently in many countries to replace Nickel-Chromium (Ni-Cr) alloys. This is mainly due to the increased concern regarding the toxic effects of Ni on the human body when alloys containing Ni are exposed to the oral cavity. This review article describes dental applications, metallurgical characterization, and physico-mechanical properties of Co-Cr alloys and also addresses their clinical and laboratory behavior in relation to those properties.

참고문헌 (47)

  1. Crook P, "Corrosion", pp.657~700 (1987), ASM International
  2. Evans EJ., "The in vitro toxicity of cobalt-chromemolybdenum alloy and its constituent metals", Biomaterials, 7, pp.25~29 (1986)
  3. Craig RG., "Reaction of fibroblasts to various dental casting alloys", J Oral Pathol, 17, pp.341~347 (1988)
  4. Viennot S., "Corrosion resistance of cobalt-chromium and palladium-silver alloys used in fixed prosthetic restorations", Eur J Oral Sci, 113, pp.90~95 (2005)
  5. Mueller H., "Corrosion", pp.1351~1352 (1987), ASM International
  6. Marti A., "Cobalt-base alloys used in bone surgery", Injury, 31, pp.18~21 (2000)
  7. "ANSI", ADA Specification No. 38. Classification system for cast alloys. Council on Dental Materials, Instruments, and Equipment, 1984, pp.109, 766~
  8. "ISO 6871-1. Dental base metal alloys. Part 1: Cobalt-based alloys", International Organization for Standardization, ~ (1994)
  9. Wataha JC., "Alloys for prosthodontic restorations", J Prosthet Dent, 87, pp.351~363 (2002)
  10. Asgar K., "Effect of microstructure on the physical properties of cobalt-base alloys", J Dent Res, 40, pp.63~72 (1961)
  11. Herö H., "Ductility and structure of some cobalt-base dental casting alloys", Biomaterials, 5, pp.201~208 (1984)
  12. Asgar K., "Microstructure and physical properties of alloys for partial denture castings", J Dent Res, 47, pp.189~197 (1968)
  13. Anusavice KJ., "Phillips’ science of dental materials", pp.423~459 (1996), WB Saunders
  14. van Noort R., "A scanning electron microscope study of Co-Cr partial dentures fractured in service", J Dent, 12, pp.122~126 (1984)
  15. Geis-Gerstorfer J., "Ion release from NiCr-Mo and Co-Cr-Mo casting alloys", Int J Prosthodont, 4, pp.152~158 (1991)
  16. Geis-Gerstorfer J., "In vitro corrosion behavior of four Ni-Cr dental alloys in lactic acid and sodium chloride solutions", Dent Mater, 3, pp.289~295 (1987)
  17. Okazaki Y., "Comparison of metal release from various metallic biomaterials in vitro", Biomaterials, 26, pp.11~21 (2005)
  18. Montero-Ocampo C., "Effect of carbon content on the resistance to localized corrosion of as-cast cobalt-based alloys in an aqueous chloride solution", J Biomed Mater Res, 29, pp.441~453 (1995)
  19. Yeung AL., "Oral health status of patients 5-6 years after placement of cobalt-chromium removable partial dentures", J Oral Rehabil, 27, pp.183~189 (2000)
  20. Chandler JA., "Clinical evaluation of patients eight to nine years after placement of removable partial dentures", J Prosthet Dent, 51, pp.736~743 (1984)
  21. Schwalm CA., "A clinical study of patients 1 to 2 years after placement of removable partial dentures", J Prosthet Dent, 38, pp.380~391 (1977)
  22. Bergman B., "Cross-sectional study of the periodontal status of removable partial denture patients", J Prosthet Dent, 61, pp.208~211 (1989)
  23. Budtz-Jørgensen E., "A 5-year longitudinal study of cantilevered fixed partial dentures compared with removable partial dentures in a geriatric population", J Prosthet Dent, 64, pp.42~47 (1990)
  24. Yannikakis SA., "Removable partial denture repairs : A survey", Quintessence Dent Technol, 23, pp.184~190 (2000)
  25. Körber E., "Control studies on periodontal and periodontal-gingival retention of partial prosthesis", Dtsch Zahnärztl Z, 30, pp.77~84 (1975)
  26. Vermeulen AH., "Ten-year evaluation of removable partial dentures : survival rates based on retreatment, not wearing and replacement", J Prosthet Dent, 76, pp.267~272 (1996)
  27. Bates JF., "Studies related to the fracture of partial dentures; Flexural fatigue of a cobalt-chromium alloy", Br Dent J, 118, pp.532~537 (1965)
  28. Bates JF., "Studies related to the fracture of partial dentures. The functional strain in cobalt-chromium dentures. A preliminary report", Br Dent J, 120, pp.79~83 (1966)
  29. Elarbi EA., "Radiographic detection of porosities in removable partial denture castings", J Prosthet Dent, 54, pp.674~677 (1985)
  30. Dharmar S., "Radiographic and metallographic evaluation of porosity defects and grain structure of cast chromium cobalt removable partial dentures", J Prosthet Dent, 69, pp.369~373 (1993)
  31. Lewis AJ., "Radiographic evaluation of porosities in removable partial denture castings", J Prosthet Dent, 39, pp.278~281 (1978)
  32. Lewis AJ., "Failure of removable partial denture castings during service", J Prosthet Dent, 39, pp.147~149 (1978)
  33. Lewis AJ., "Microporosity in casting alloys", Aust Dent J, 20, pp.161~166 (1975)
  34. Wictorin L., "Roentgenological detection of casting defects in cobalt-chromium alloy frameworks", J Oral Rehabil, 6, pp.137~146 (1979)
  35. Eisenburger M., "Radiological examination of dental castings-a review of the method and comparisons of the equipment", J Oral Rehabil, 29, pp.609~614 (2002)
  36. Jang KS., "Comparison of castability and surface roughness of commercially pure titanium and cobaltchromium denture frameworks", J Prosthet Dent, 86, pp.93~98 (2001)
  37. Morris H., "Stress distribution within circumferential clasp arms", J Oral Rehabil, 3, pp.387~394 (1976)
  38. Bridgeman JT., "Comparison of titanium and cobalt-chromium removable partial denture clasps", J Prosthet Dent, 78, pp.187~193 (1997)
  39. Au AR., "Titanium for removable partial dentures(III) : 2-year clinical follow-up in an undergraduate programme", J Oral Rehabil, 27, pp.979~985 (2000)
  40. Lassila LV., "Effect of water and artificial saliva on the low cycle fatigue resistance of cobalt-chromium dental alloy", J Prosthet Dent, 80, pp.708~713 (1998)
  41. Angelini E., "Tensile strength of Cr-Co dental alloys solder joints", Dent Mater, 5, pp.13~17 (1989)
  42. Louly AC., "Tensile strength of preceramic solder joints formed using an infrared heat source", Int J Prosthodont, 4, pp.425~431 (1991)
  43. Pattee HE., "Source book on brazing and brazing technology", pp.17~63 (1980), ASM International
  44. Luthy H., "Corrosion considerations in the brazing repair of cobalt-based partial dentures", J Prosthet Dent, 75, pp.515~524 (1996)
  45. Bertrand C., "The laser welding technique applied to the non precious dental alloys procedure and results", Br Dent J, 190, pp.255~257 (2001)
  46. Bertrand C., "Proposals for optimization of laser welding in prosthetic dentistry", J Prosthodont, 19, pp.69~76 (2010)
  47. van Noort R., "The future of dental devices is digital", Dent Mater, 28, pp.3~12 (2012)

관련 논문AI추천

Dental Co-Cr alloys fabricated by selective laser melting: A review article강현구대한치과보철학회 · 대한치과보철학회지2021 · 제59권 제2호The effect of repeated porcelain firings on corrosion resistance of different dental alloysAli Riza Tuncdemir, Ismail Karahan, Mehmet Dalkiz, Meral Arslan Malkoc, Serdar Polat대한치과보철학회 · The Journal of Advanced of Prosthodontics2013 · 제5권 제1호Annealing of Co-Cr dental alloy: effects on nanostructure and Rockwell hardnessBulent Pişkin, Cumhur Sipahi, Elif Hilal Soylu, Hasan Suat Göç, Selim Kılıç, Semra İde, Simel Ayyıldız대한치과보철학회 · The Journal of Advanced of Prosthodontics2013 · 제5권 제4호Comparison of the bond strength of ceramics to Co-Cr alloys made by casting and selective laser meltingArash Azizi, Mahtasadat Afradeh, Shahbaz Nasermostofi, Shirin Lawaf대한치과보철학회 · The Journal of Advanced of Prosthodontics2017 · 제9권 제1호Fractured Surface Morphology and Mechanical Properties of Ni-Cr Based Alloys with Mo Content for Dental Applications김현수, 손미경, 최한철한국표면공학회 · 한국표면공학회지2016 · 제49권 제3호Comparison of the mechanical properties and microstructures of fractured surface for Co-Cr alloy fabricated by conventional cast, 3-D printing laser-sintered and CAD/CAM milled techniques곽재영, 김성균, 박동수, 안진수, 최윤정, 허성주대한치과보철학회 · 대한치과보철학회지2014 · 제52권 제2호