Gap comparison between single crown and three-unit bridge zirconia substructures

1

조회

0

다운로드

3

인용

0

참고문헌

키워드

초록

PURPOSE. To compare marginal and internal gaps of zirconia substructure of single crowns with those of three unit fixed dental prostheses. MATERIALS AND METHODS. Standardized Co-Cr alloy simulated second premolar and second molar abutments were fabricated and subsequently duplicated into type-III dental stone for working casts. After that, all zirconia substructures were made using LavaTM system. Marginal and internal gaps were measured in 2 planes (mesial-distal plane and buccal-palatal plane) at 5 locations: marginal opening (MO), chamfer area (CA), axial wall (AW), cusp tip (CT) and mid-occlusal (OA) using Replica technique. RESULTS. There were significant differences between gaps at all locations. The mean ± SD of marginal gap in premolar was 43.6 ± 0.4 μm and 46.5 ± 0.5 μm for single crown and 3-unit bridge substructure respectively. For molar substructure the mean ± SD of marginal gap was 48.5 ± 0.4 μm and 52.6 ± 0.4 μm for single crown and 3-unit bridge respectively. The largest gaps were found at the occlusal area, which was 150.5 ± 0.5 μm and 154.5 ± 0.4 μm for single and 3-unit bridge premolar substructures respectively and 146.5 ± 0.4 μm and 211.5 ± 0.4 μm for single and 3-unit bridge molar substructure respectively. CONCLUSION. Independent-samples t-test showed significant differences of gap in zirconia substructure between single crowns and three-unit bridge (P<.001). Therefore, the span length has the effect on the fit of zirconia substructure that is fabricated using CAD/CAMtechnique especially at the occlusal area.

Abstract

PURPOSE. To compare marginal and internal gaps of zirconia substructure of single crowns with those of three unit fixed dental prostheses. MATERIALS AND METHODS. Standardized Co-Cr alloy simulated second premolar and second molar abutments were fabricated and subsequently duplicated into type-III dental stone for working casts. After that, all zirconia substructures were made using LavaTM system. Marginal and internal gaps were measured in 2 planes (mesial-distal plane and buccal-palatal plane) at 5 locations: marginal opening (MO), chamfer area (CA), axial wall (AW), cusp tip (CT) and mid-occlusal (OA) using Replica technique. RESULTS. There were significant differences between gaps at all locations. The mean ± SD of marginal gap in premolar was 43.6 ± 0.4 μm and 46.5 ± 0.5 μm for single crown and 3-unit bridge substructure respectively. For molar substructure the mean ± SD of marginal gap was 48.5 ± 0.4 μm and 52.6 ± 0.4 μm for single crown and 3-unit bridge respectively. The largest gaps were found at the occlusal area, which was 150.5 ± 0.5 μm and 154.5 ± 0.4 μm for single and 3-unit bridge premolar substructures respectively and 146.5 ± 0.4 μm and 211.5 ± 0.4 μm for single and 3-unit bridge molar substructure respectively. CONCLUSION. Independent-samples t-test showed significant differences of gap in zirconia substructure between single crowns and three-unit bridge (P<.001). Therefore, the span length has the effect on the fit of zirconia substructure that is fabricated using CAD/CAMtechnique especially at the occlusal area.

참고문헌 (38)

  1. Rosenblum MA., "A review of all-ceramic restorations", J Am Dent Assoc, 128, pp.297~307 (1997)
  2. Magne P., "Esthetic improvements and in vitro testing of In-Ceram Alumina and Spinell ceramic", Int J Prosthodont, 10, pp.459~466 (1997)
  3. Shepard FE., "Allergic contact stomatitis from a gold alloy-fixed partial denture", J Am Dent Assoc, 106, pp.198~199 (1983)
  4. McLean JW., "The reinforcement of dental porcelain with ceramic oxides", Br Dent J, 119, pp.251~267 (1965)
  5. Kelly JR., "Failure of all-ceramic fixed partial dentures in vitro and in vivo : analysis and modeling", J Dent Res, 74, pp.1253~1258 (1995)
  6. Olsson KG., "A longterm retrospective and clinical follow-up study of In-Ceram Alumina FPDs", Int J Prosthodont, 16, pp.150~156 (2003)
  7. Sorensen JA., "A clinical investigation on three-unit fixed partial dentures fabricated with a lithium disilicate glass-ceramic", Pract Periodontics Aesthet Dent, 11, pp.95~106 (1999)
  8. Sorensen JA., "In-Ceram fixed partial dentures : three-year clinical trial results", J Calif Dent Assoc, 26, pp.207~214 (1998)
  9. Vult von Steyern P., "Five-year evaluation of posterior all-ceramic three-unit(In-Ceram)FPDs", Int J Prosthodont, 14, pp.379~384 (2001)
  10. Libby G., "Longevity of fixed partial dentures", J Prosthet Dent, 78, pp.127~131 (1997)
  11. Campbell SD., "Evaluation of the fit and strength of an all-ceramic fixed partial denture", J Prosthet Dent, 59, pp.301~306 (1988)
  12. Kelly JR., "Dental ceramics: current thinking and trends", Dent Clin North Am, 48, pp.513~530 (2004)
  13. Denry I., "State of the art of zirconia for dental applications", Dent Mater, 24, pp.299~307 (2008)
  14. Abduo J., "Fit of zirconia fixed partial denture : a systematic review", J Oral Rehabil, 37, pp.866~876 (2010)
  15. Sailer I., "Five-year clinical results of zirconia frameworks for posterior fixed partial dentures", Int J Prosthodont, 20, pp.383~388 (2007)
  16. Sailer I., "A systematic review of the survival and complication rates of allceramic and metal-ceramic reconstructions after an observation period of at least 3 years. Part II : Fixed dental prostheses", Clin Oral Implants Res, 18, pp.86~96 (2007)
  17. Raigrodski AJ., "Contemporary materials and technologies for all-ceramic fixed partial dentures : a review of the literature", J Prosthet Dent, 92, pp.557~562 (2004)
  18. Raigrodski AJ., "Contemporary all-ceramic fixed partial dentures: a review.", Dent Clin North Am, 48, pp.531~544 (2004)
  19. Devigus A., "Shading Vita YZ substructures : influence on value and chroma, part I", Int J Comput Dent, 7, pp.293~301 (2004)
  20. Beuer F., "Marginal fit of 14-unit zirconia fixed dental prosthesis retainers", J Oral Rehabil, 36, pp.142~149 (2009)
  21. Glauser R., "Experimental zirconia abutments for implant-supported single-tooth restorations in esthetically demanding regions : 4-year results of a prospective clinical study", Int J Prosthodont, 17, pp.285~290 (2004)
  22. Lang NP., "Clinical and microbiological effects of subgingival restorations with overhanging or clinically perfect margins", J Clin Periodontol, 10, pp.563~578 (1983)
  23. Valderhaug J., "Oral hygiene in a group of supervised patients with fixed prostheses", J Periodontol, 48, pp.221~224 (1977)
  24. Reich S., "Clinical fit of all-ceramic three-unit fixed partial dentures, generated with three different CAD", CAM systems, 2005, pp.113, 174~179
  25. Bindl A., "Marginal and internal fit of all-ceramic CAD", CAM crown-copings on chamfer preparations, 2005, pp.32, 441~447
  26. Schaerer P., "A comparison of the marginal fit of three cast ceramic crown systems", J Prosthet Dent, 59, pp.534~542 (1988)
  27. Hung SH., "Marginal fit of porcelain-fused-to-metal and two types of ceramic crown", J Prosthet Dent, 63, pp.26~31 (1990)
  28. Weaver JD., "Marginal adaptation of castable ceramic crowns", J Prosthet Dent, 66, pp.747~753 (1991)
  29. Boening KW., "Non-cast titanium restorations in fixed prosthodontics", J Oral Rehabil, 19, pp.281~287 (1992)
  30. Fransson B., "The fit of metal-ceramic crowns, a clinical study", Dent Mater, 1, pp.197~199 (1985)
  31. Kokubo Y., "Clinical marginal and internal gaps of Procera AllCeram crowns", J Oral Rehabil, 32, pp.526~530 (2005)
  32. Quintas AF., "Vertical marginal discrepancy of ceramic copings with different ceramic materials, finish lines, and luting agents : an in vitro evaluation", J Prosthet Dent, 92, pp.250~257 (2004)
  33. Bornemann G., "Innovative method for the analysis of the internal 3D fitting accuracy of Cerec-3 crowns", Int J Comput Dent, 5, pp.177~182 (2002)
  34. Tuntiprawon M., "The effect of cement thickness on the fracture strength of all-ceramic crowns", Aust Dent J, 40, pp.17~21 (1995)
  35. Karlsson S., "A clinical evaluation of fixed bridges, 10 years following insertion", J Oral Rehabil, 13, pp.423~432 (1986)
  36. Abduo J., "Fit of zirconia fixed partial denture : a systematic review", J Oral Rehabil, 37, pp.866~876 (2010)
  37. Reich S., "Clinical fit of fourunit zirconia posterior fixed dental prostheses", Eur J Oral Sci, 116, pp.579~584 (2008)
  38. Wettstein F., "Clinical study of the internal gaps of zirconia and metal frameworks for fixed partial dentures", Eur J Oral Sci, 116, pp.272~279 (2008)

관련 논문AI추천

Effect of span length on the fit of zirconia framework fabricated using CAD/CAM system김민수, 김영수, 김하영, 신상완, 이정열, 최상진대한치과보철학회 · The Journal of Advanced of Prosthodontics2013 · 제5권 제2호Marginal fit of anterior 3-unit fixed partial zirconia restorations using different CAD/CAM systems권택가, 김성훈, 송태진, 양재호, 여인성, 이재봉, 한중석대한치과보철학회 · The Journal of Advanced of Prosthodontics2013 · 제5권 제3호다양한CAD/CAM 시스템으로 제작된 3 본 고정성 가공의치 지르코니아 코어의 변연 및 내면 적합도 평가김영수, 김우식, 김종은, 김하영, 신상완, 이정열, 전영찬, 허중보대한치과보철학회 · 대한치과보철학회지2011 · 제49권 제03호Comparison of the fit accuracy of zirconia-based prostheses generated by two CAD/CAM systems조진현, 하석준대한치과보철학회 · The Journal of Advanced of Prosthodontics2016 · 제8권 제6호Assessment of the fit of zirconia-based prostheses fabricated with two different scan methods조진현, 최현석대한치과보철학회 · 대한치과보철학회지2017 · 제55권 제2호Evaluation of the marginal and internal gaps of three different dental prostheses: comparison of the silicone replica technique and three-dimensional superimposition analysis김웅철, 김지환, 김혜영, 박진영, 배소연, 이재준대한치과보철학회 · The Journal of Advanced of Prosthodontics2017 · 제9권 제3호

이 간행물의 다른 논문 (10건)