본문 바로가기
KERD
논문KCI 등재

Measuring abutment convergence angles using stereovision dental image processing system

1

조회

0

다운로드

0

인용

0

참고문헌

키워드

초록

PURPOSE. The purpose of this study was to develop a dental image processing system using a three-dimensional (3D) camera and stereovision technology. The reliability of the system for measuring axial wall convergence angles was evaluated. MATERIALS AND METHODS. The new system predicted 3D coordinate points from 2D images and calculated distances and angles between points. Two examiners measured axial wall convergence angles for seven artificial abutments using a traditional tracing-based method (TBM) and the stereovision-based method (SVBM). Five wax abutment models of simplified abutment forms were made and axial wall convergence angles of wax models were measured by both methods. The data were statistically analyzed at the level of significance, 0.05. RESULTS. Intraclass correlation coefficients showed excellent intra-examiner and interexaminer reliabilities for both methods. Bland-Altman plots and paired t-tests showed significant differences between measurements and true values using TBM; differences were not significant with SVBM. CONCLUSION. This study found that the SVBM reflected true angle values more accurately than a TMB and illustrated an example of 3D computer science applied to clinical dentistry.

Abstract

PURPOSE. The purpose of this study was to develop a dental image processing system using a three-dimensional (3D) camera and stereovision technology. The reliability of the system for measuring axial wall convergence angles was evaluated. MATERIALS AND METHODS. The new system predicted 3D coordinate points from 2D images and calculated distances and angles between points. Two examiners measured axial wall convergence angles for seven artificial abutments using a traditional tracing-based method (TBM) and the stereovision-based method (SVBM). Five wax abutment models of simplified abutment forms were made and axial wall convergence angles of wax models were measured by both methods. The data were statistically analyzed at the level of significance, 0.05. RESULTS. Intraclass correlation coefficients showed excellent intra-examiner and interexaminer reliabilities for both methods. Bland-Altman plots and paired t-tests showed significant differences between measurements and true values using TBM; differences were not significant with SVBM. CONCLUSION. This study found that the SVBM reflected true angle values more accurately than a TMB and illustrated an example of 3D computer science applied to clinical dentistry.

참고문헌 (30)

  1. Bradski GR., "Learning OpenCV: computer vision with the OpenCV library", pp.555~ (2008), O’Reilly
  2. "The glossary of prosthodontic terms", J Prosthet Dent, 94, pp.10~92 (2005)
  3. Al-Omari WM., "Convergence angle, occlusal reduction, and finish line depth of full-crown preparations made by dental students", Quintessence Int, 35, pp.287~293 (2004)
  4. el-Ebrashi MK., "Experimental stress analysis of dental restorations. IV. The concept of parallelism of axial walls", J Prosthet Dent, 22, pp.346~353 (1969)
  5. Goodacre CJ., "Tooth preparations for complete crowns : an art form based on scientific principles", J Prosthet Dent, 85, pp.363~376 (2001)
  6. Jørgensen KD., "The relationship between retention and convergence angle in cemented veneer crowns", Acta Odontol Scand, 13, pp.35~40 (1955)
  7. Kaufman EG., "Factors influencing the retention of cemented gold castings", J Prosthet Dent, 11, pp.487~502 (1961)
  8. Weed RM., "Determining adequate crown convergence", Tex Dent J, 98, pp.14~16 (1980)
  9. Wilson AH Jr., "The relationship between preparation convergence and retention of extracoronal retainers", J Prosthodont, 3, pp.74~78 (1994)
  10. Lewis RM., "A mathematical solution of a problem in full crown construction", J Am Dent Assoc, 59, pp.943~947 (1959)
  11. Weed RM., "A method for determining adequate resistance form of complete cast crown preparations", J Prosthet Dent, 52, pp.330~334 (1984)
  12. Chandra Shekar S., "An in vitro study to evaluate the retention of complete crowns prepared with five different tapers and luted with two different cements", J Indian Prosthodont Soc, 10, pp.89~95 (2010)
  13. el-Ebrashi MK., "Experimental stress analysis of dental restorations. VI. The concept of proximal reduction in compound restorations", J Prosthet Dent, 22, pp.663~670 (1969)
  14. Shillingburg HT Jr., "Fundamentals of fixed prosthodontics", pp.131~148 (2012), Quintessence Publishing Co. Ltd
  15. Annerstedt A., "Axial wall convergence of full veneer crown preparations. Documented for dental students and general practitioners", Acta Odontol Scand, 54, pp.109~112 (1996)
  16. Mack PJ., "A theoretical and clinical investigation into the taper achieved on crown and inlay preparations", J Oral Rehabil, 7, pp.255~265 (1980)
  17. Ayad MF., "Assessment of convergence angles of tooth preparations for complete crowns among dental students", J Dent, 33, pp.633~638 (2005)
  18. Dodge WW., "The effect of convergence angle on retention and resistance form", Quintessence Int, 16, pp.191~194 (1985)
  19. Leempoel PJ., "The convergence angle of tooth preparations for complete crowns", J Prosthet Dent, 58, pp.414~416 (1987)
  20. Ohm E., "The convergence angle in teeth prepared for artificial crowns", J Oral Rehabil, 5, pp.371~375 (1978)
  21. Smith CT., "Effective taper criterion for the full veneer crown preparation in preclinical prosthodontics", J Prosthodont, 8, pp.196~200 (1999)
  22. Velasquez-Plata D., "The art of crown preparation: a review of principles", J Indiana Dent Assoc, 75, pp.6~11 (1996)
  23. Kent WA., "Taper of clinical preparations for cast restorations", Quintessence Int, 19, pp.339~345 (1988)
  24. Noonan JE Jr., "Convergence of the axial walls of full veneer crown preparations in a dental school environment", J Prosthet Dent, 66, pp.706~708 (1991)
  25. Nordlander J., "The taper of clinical preparations for fixed prosthodontics", J Prosthet Dent, 60, pp.148~151 (1988)
  26. de Vet HC., "When to use agreement versus reliability measures", J Clin Epidemiol, 59, pp.1033~1039 (2006)
  27. Shrout PE., "Intraclass correlations : uses in assessing rater reliability", Psychol Bull, 86, pp.420~428 (1979)
  28. Weir JP., "Quantifying test-retest reliability using the intraclass correlation coefficient and the SEM", J Strength Cond Res, 19, pp.231~240 (2005)
  29. Doros G., "Design based on intra-class correlation coefficients", Am J Biostat, 1, pp.1~8 (2010)
  30. Landis JR., "The measurement of observer agreement for categorical data", Biometrics, 33, pp.159~174 (1977)

관련 논문AI추천

The reliability of an easy measuring method for abutment convergence angle with a computer-aided design (CAD) system권택가, 김성훈, 여인성, 이재봉, 한중석, Yong-Joon Seo대한치과보철학회 · The Journal of Advanced of Prosthodontics2014 · 제6권 제3호Influence of camera position, implant angulation and implant reference on the accuracy of complete arch implant recordings with photogrammetryAlicia Martínez-Marugán, Ana Suarez-García, Andrea Santamaria-Laorden, Israel John Thuissard, Jaime Orejas-Pérez, Meriem Benabdallah-M’Rabat, Sabina Francesca Bertuol-Gessi대한치과보철학회 · The Journal of Advanced of Prosthodontics2025 · 제17권 제5호Evaluation of the effect of abutment preparation angles on the repeatability and reproducibility using a blue light model scanner김동연대한치과보철학회 · The Journal of Advanced of Prosthodontics2020 · 제12권 제4호Accuracy of 3D white light scanning of abutment teeth impressions: evaluation of trueness and precision김웅철, 김지환, 김혜영, 전진훈대한치과보철학회 · The Journal of Advanced of Prosthodontics2014 · 제6권 제6호Reverse engineering technique on the evaluation of impression accuracy in angulated implants박진홍, 송소연, 이기선, 이정열, 정홍택대한치과보철학회 · 대한치과보철학회지2021 · 제59권 제3호White light scanner-based repeatability of 3-dimensional digitizing of silicon rubber abutment teeth impressions김웅철, 김지환, 김혜영, 이경탁, 전진훈대한치과보철학회 · The Journal of Advanced of Prosthodontics2013 · 제5권 제4호

이 간행물의 다른 논문 (10건)