Effect of span length on the fit of zirconia framework fabricated using CAD/CAM system

2

조회

0

다운로드

1

인용

0

참고문헌

키워드

초록

PURPOSE. The purpose of this study was to evaluate the effect of the span length on the fit of zirconia framework fabricated using CAD/CAM system. MATERIALS AND METHODS. Abutments for single, 4-unit and 6-unit fixed partial prostheses were fabricated. Ten zirconia frameworks were fabricated for each group. The marginal and internal gap were presented by means of replica technique and measured by measuring microscope (AXIO®, Carl Zeiss, Rochester, NY) and software (I-solution®, IMT i-solution Inc., Vancouver, BC, Canada). The results were statistically analyzed by multivariate analysis test and Dunnett T3 test for post hoc test (α=.05). RESULTS. There were statistically significant differences at 2, 4, 7, 8 points (mesio-distal section) and b, d, e, f, g (labio-lingual section). In some marginal reference points of 6-unit group (P<.05), the marginal gap were larger than 120 μm. CONCLUSION. Span length of zirconia core may have an influence on marginal and internal fit. Within the limitation of this study, the increase of span length of zirconia framework of 6 or more-unit fixed partial denture may decrease the marginal and internal fit.

Abstract

PURPOSE. The purpose of this study was to evaluate the effect of the span length on the fit of zirconia framework fabricated using CAD/CAM system. MATERIALS AND METHODS. Abutments for single, 4-unit and 6-unit fixed partial prostheses were fabricated. Ten zirconia frameworks were fabricated for each group. The marginal and internal gap were presented by means of replica technique and measured by measuring microscope (AXIO®, Carl Zeiss, Rochester, NY) and software (I-solution®, IMT i-solution Inc., Vancouver, BC, Canada). The results were statistically analyzed by multivariate analysis test and Dunnett T3 test for post hoc test (α=.05). RESULTS. There were statistically significant differences at 2, 4, 7, 8 points (mesio-distal section) and b, d, e, f, g (labio-lingual section). In some marginal reference points of 6-unit group (P<.05), the marginal gap were larger than 120 μm. CONCLUSION. Span length of zirconia core may have an influence on marginal and internal fit. Within the limitation of this study, the increase of span length of zirconia framework of 6 or more-unit fixed partial denture may decrease the marginal and internal fit.

참고문헌 (24)

  1. Seghi RR, "Relative fracture toughness and hardness of new dental ceramics", J Prosthet Dent, 74, pp.145~150 (1995)
  2. Reich S, "Clinical fit of fourunit zirconia posterior fixed dental prostheses", Eur J Oral Sci, 116, pp.579~584 (2008)
  3. Luthardt RG, "Reliability and properties of ground Y-TZP-zirconia ceramics", J Dent Res, 81, pp.487~491 (2002)
  4. Tinschert J, "Marginal fit of alumina-and zirconia-based fixed partial dentures produced by a CAD", CAM system, 2001, pp.26, 367~374
  5. Suttor D, "LAVA-the system for all-ceramic ZrO2 crown and bridge frameworks", Int J Comput Dent, 4, pp.195~120 (2001)
  6. Belser UC, "Fit of three porcelain-fused-to-metal marginal designs in vivo: a scanning electron microscope study", J Prosthet Dent, 53, pp.24~29 (1985)
  7. Karlsson S, "The fit of Procera titanium crowns. An in vitro and clinical study", Acta Odontol Scand, 51, pp.129~134 (1993)
  8. Reich S, "Clinical fit of all-ceramic three-unit fixed partial dentures, generated with three different CAD", CAM systems, 2005, pp.113, 174~179
  9. Bindl A, "Marginal and internal fit of all-ceramic CAD", CAM crown-copings on chamfer preparations, 2005, pp.32, 441~447
  10. Sulaiman F, "A comparison of the marginal fit of In-Ceram, IPS Empress, and Procera crowns", Int J Prosthodont, pp.478~484 (1997)
  11. Tuntiprawon M, "The effect of cement thickness on the fracture strength of all-ceramic crowns", Aust Dent J, 40, pp.17~21 (1995)
  12. Lawn BR, "Materials design in the performance of all-ceramic crowns", Biomaterials, 25, pp.288592~ (2004)
  13. Thompson VP, "Dental ceramics and the molar crown testing ground", J Appl Oral Sci, 12, pp.26~36 (2004)
  14. Rekow D, "Near-surface damage-a persistent problem in crowns obtained by computer-aided design and manufacturing", Proc Inst Mech Eng H, 219, pp.233~243 (2005)
  15. Sailer I, "Five-year clinical results of zirconia frameworks for posterior fixed partial dentures", Int J Prosthodont, 20, pp.383~388 (2007)
  16. Tinschert J, "Clinical behavior of zirconia-based fixed partial dentures made of DC-Zirkon: 3-year results", Int J Prosthodont, 21, pp.217~222 (2008)
  17. Molin MK, "Five-year clinical prospective evaluation of zirconia-based Denzir 3-unit FPDs", Int J Prosthodont, 21, pp.223~227 (2008)
  18. Beuer F, "Precision of fit: zirconia three-unit fixed dental prostheses", Clin Oral The Journal of Advanced Prosthodontics 125 Investig, 13, pp.343~349 (2009)
  19. Hung SH, "Marginal fit of porcelain-fused-to-metal and two types of ceramic crown", J Prosthet Dent, 63, pp.26~31 (1990)
  20. Abduo J, "Fit of zirconia fixed partial denture: a systematic review", J Oral Rehabil, 37, pp.866~876 (2010)
  21. May KB, "Precision of fit: the Procera AllCeram crown", J Prosthet Dent, 80, pp.394~404 (1998)
  22. Rahme HY, "In vitro evaluation of the “replica technique” in the measurement of the fit of Procera crowns", J Contemp Dent Pract, 9, pp.25~32 (2008)
  23. Laurent M, "Clinical evaluation of the marginal fit of cast crowns-validation of the silicone replica method", J Oral Rehabil, 35, pp.116~122 (2008)
  24. Moldovan O, "Threedimensional fit of CAD", CAM-made zirconia copings, 2011, pp.27, 1273~1278

관련 논문AI추천

이 간행물의 다른 논문 (19건)