PURPOSE. The marginal bone loss of implants with laser treated surface was investigated after six weeks of loading after implant installation to the mandible molar area. MATERIALS AND METHODS. A total of 23 implants were placed in the edentulous molar area of the mandible: 13 implants were immediately loaded and 10 implants were early loaded. The implants used were made of titanium grade 23, screw shaped, 4.2 mm in diameter, and 10 mm in length. Patients were evaluated with resonance frequency analysis at implant fixture installation and 1, 2 (final prosthesis installation), 3, 5, 8, and 14 months later. X-rays were taken at 2 months after fixture installation and 1, 2, 3 years after to measure the marginal bone loss. RESULTS. The mean ISQ value measured at the implant installation was over 70 at all-time points. The average of marginal bone loss was average 0.33 mm. CONCLUSION. Immediate implant loading for laser treated implants would be possible.
Abstract
PURPOSE. The marginal bone loss of implants with laser treated surface was investigated after six weeks of loading after implant installation to the mandible molar area. MATERIALS AND METHODS. A total of 23 implants were placed in the edentulous molar area of the mandible: 13 implants were immediately loaded and 10 implants were early loaded. The implants used were made of titanium grade 23, screw shaped, 4.2 mm in diameter, and 10 mm in length. Patients were evaluated with resonance frequency analysis at implant fixture installation and 1, 2 (final prosthesis installation), 3, 5, 8, and 14 months later. X-rays were taken at 2 months after fixture installation and 1, 2, 3 years after to measure the marginal bone loss. RESULTS. The mean ISQ value measured at the implant installation was over 70 at all-time points. The average of marginal bone loss was average 0.33 mm. CONCLUSION. Immediate implant loading for laser treated implants would be possible.
참고문헌 (15)
- Wismeijer D, "ITI treatment guide Volume 4, Loading protocol in implant dentistry", pp.6~8 (2010), Quintessence
- Rupp F, "Enhancing surface free energy and hydrophilicity through chemical modification of microstructured titanium implant surfaces", J Biomed Mater Res A, 76, pp.323~334 (2006)
- Hofmann AA, "Progression of human bone ingrowth into porous-coated implants. Rate of bone ingrowth in humans", Acta Orthop Scand, 68, pp.161~166 (1997)[DOI]
- Zhao G, "High surface energy enhances cell response to titanium substrate microstructure", J Biomed Mater Res A, 74, pp.49~58 (2005)
- Wennerberg A, "Current knowledge about the hydrophilic and nanostructured SLActive surface", Clin Cosmet Investig Dent, 3, pp.59~67 (2011)[DOI]
- Hall J, "Stimulation of directed bone growth at oxidized titanium implants by macroscopic grooves: an in vivo study", Clin Implant Dent Relat Res, 7, pp.S76~S82 (2005)[DOI]
- 2.0.CO;2,
- Schwartz Z, "Effect of titanium surface roughness on chondrocyte proliferation, matrix production, and differentiation depends on the state of cell maturation", J Biomed Mater Res, 30, pp.145~155 (1996)[DOI]
- Roccuzzo M, "Early loading of sandblasted and acid-etched (SLA) implants: a prospective split-mouth comparative study", Clin Oral Implants Res, 12, pp.572~578 (2001)[DOI]
- Cochran DL, "The use of reduced healing times on ITI implants with a sandblasted and acid-etched (SLA) surface: early results from clinical trials on ITI SLA implants", Clin Oral Implants Res, 13, pp.144~153 (2002)[DOI]
- Cochran D, "Clinical field trial examining an implant with a sand-blasted, acid-etched surface", J Periodontol, 78, pp.974~982 (2007)[DOI]
- Hallgren C, "An in vivo study of bone response to implants topographically modified by laser micromachining", Biomaterials, 24, pp.701~710 (2003)[DOI]
- 강남석, "Comparison of removal torques between laser-treated and SLAtreated implant surfaces in rabbit tibiae", The Journal of Advanced of Prosthodontics, 6(4), pp.302~308 (2014), 대한치과보철학회[DOI]
- Gaggl A, "Scanning electron microscopical analysis of laser-treated titanium implant surfaces-a comparative study", Biomaterials, 21, pp.1067~1073 (2000)[DOI]