The effect of erbium-doped: yttrium, aluminium and garnet laser irradiation on the surface microstructure and roughness of double acidetched implants
2
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Purpose: One of the most frequent complications related to dental implants is peri-implantitis, and the characteristics of implant surfaces are closely related to the progression and resolution of inflammation. Therefore, a technical modality that can effectively detoxify the implant surface without modification to the surface is needed. The purpose of this study was to evaluate the effect of erbium-doped: yttrium, aluminium and garnet (Er:YAG) laser irradiation on the microstructural changes in double acid-etched implant surfaces according to the laser energy and the application duration. Methods: The implant surface was irradiated using an Er:YAG laser with different application energy levels (100 mJ/pulse, 140mJ/pulse, and 180 mJ/pulse) and time periods (1 minute, 1.5 minutes, and 2 minutes). We then examined the change in surface roughness value and microstructure. Results: In a scanning electron microscopy evaluation, the double acid-etched implant surface was not altered by Er:YAG laser irradiation under the condition of 100 mJ/pulse at 10 Hz for any of the irradiation times. However, we investigated the reduced sharpness of the specific ridge microstructure that resulted under the 140 mJ/pulse and 180 mJ/pulse conditions. The reduction in sharpness became more severe as laser energy and application duration increased. In the roughness measurement,the double acid-etched implants showed a low roughness value on the valley area before the laser irradiation. Under all experimental conditions, Er:YAG laser irradiation led to a minor decrease in surface roughness, which was not statistically significant. Conclusions: The recommended application settings for Er:YAG laser irradiation on double acid-etched implant surface is less than a 100 mJ/pulse at 10 Hz, and for less than two minutes in order to detoxify the implant surface without causing surface modification.
Abstract
Purpose: One of the most frequent complications related to dental implants is peri-implantitis, and the characteristics of implant surfaces are closely related to the progression and resolution of inflammation. Therefore, a technical modality that can effectively detoxify the implant surface without modification to the surface is needed. The purpose of this study was to evaluate the effect of erbium-doped: yttrium, aluminium and garnet (Er:YAG) laser irradiation on the microstructural changes in double acid-etched implant surfaces according to the laser energy and the application duration. Methods: The implant surface was irradiated using an Er:YAG laser with different application energy levels (100 mJ/pulse, 140mJ/pulse, and 180 mJ/pulse) and time periods (1 minute, 1.5 minutes, and 2 minutes). We then examined the change in surface roughness value and microstructure. Results: In a scanning electron microscopy evaluation, the double acid-etched implant surface was not altered by Er:YAG laser irradiation under the condition of 100 mJ/pulse at 10 Hz for any of the irradiation times. However, we investigated the reduced sharpness of the specific ridge microstructure that resulted under the 140 mJ/pulse and 180 mJ/pulse conditions. The reduction in sharpness became more severe as laser energy and application duration increased. In the roughness measurement,the double acid-etched implants showed a low roughness value on the valley area before the laser irradiation. Under all experimental conditions, Er:YAG laser irradiation led to a minor decrease in surface roughness, which was not statistically significant. Conclusions: The recommended application settings for Er:YAG laser irradiation on double acid-etched implant surface is less than a 100 mJ/pulse at 10 Hz, and for less than two minutes in order to detoxify the implant surface without causing surface modification.
참고문헌 (39)
- Albrektsson TO, "Biological aspects of implant dentistry: osseointegration", Periodontol 2000, 4, pp.58~73 (1994)
- Mombelli A, "The diagnosis and treatment of peri-implantitis", Periodontol 2000, 17, pp.63~76 (1998)
- Quirynen M, "A study of 589 consecutive implants supporting complete fixed prostheses. Part I: Periodontal aspects", J Prosthet Dent, 68, pp.655~663 (1992)
- Isidor F, "Loss of osseointegration caused by occlusal load of oral implants. A clinical and radiographic study in monkeys", Clin Oral Implants Res, 7, pp.143~152 (1996)
- Pongnarisorn NJ, "Inflammation associated with implants with different surface types", Clin Oral Implants Res, 18, pp.114~125 (2007)
- Meffert RM, "Dental implants: a review", J Periodontol, 63, pp.859~870 (1992)
- Mombelli A, "Microbiology and antimicrobial therapy of peri-implantitis", Periodontol 2000, 28, pp.177~189 (2002)
- Krozer A, "Chemical treatment of machined titanium surfaces. An in vitro study", Clin Oral Implants Res, 10, pp.204~211 (1999)
- Schwarz F, "Effect of an Er:YAG laser on periodontally involved root surfaces: an in vivo and in vitro SEM comparison", Lasers Surg Med, 29, pp.328~335 (2001)
- Schwarz F, "In vivo and in vitro effects of an Er:YAG laser, a GaAlAs diode laser, and scaling and root planing on periodontally diseased root surfaces: a comparative histologic study", Lasers Surg Med, 32, pp.359~366 (2003)
- Ando Y, "Bactericidal effect of erbium YAG laser on periodontopathic bacteria", Lasers Surg Med, 19, pp.190~200 (1996)
- Yamaguchi H, "Effects of irradiation of an erbium:YAG laser on root surfaces", J Periodontol, 68, pp.1151~1155 (1997)
- Matsuyama T, "Effects of the Er:YAG laser irradiation on titanium implant materials and contaminated implant abutment surfaces", J Clin Laser Med Surg, 21, pp.7~17 (2003)
- Albrektsson T, "Oral implant surfaces: Part 1--review focusing on topographic and chemical properties of different surfaces and in vivo responses to them", Int J Prosthodont, 17, pp.536~543 (2004)
- De Leonardis D, "Osseointegration of rough acid-etched titanium implants: 5-year follow-up of 100 minimatic implants", Int J Oral Maxillofac Implants, 14, pp.384~391 (1999)
- Wennerberg A, "A 1-year follow-up of implants of differing surface roughness placed in rabbit bone", Int J Oral Maxillofac Implants 1997, 12, pp.486~494 (1997)
- Lazzara RJ, "A hu man histologic analysis of osseotite and machined surfaces using implants with 2 opposing surfaces", Int J Periodontics Restorative Dent, 19, pp.117~129 (1999)
- London RM, "Histologic comparison of a thermal dual-etched implant surface to machined, TPS, and HA surfaces: bone contact in vivo in rabbits", Int J Oral Maxillofac Implants, 17, pp.369~376 (2002)
- Park JY, "Red blood cell and platelet interactions with titanium implant surfaces", Clin Oral Implants Res, 11, pp.530~539 (2000)
- Bowers KT, "Optimization of surface micromorphology for enhanced osteoblast responses in vitro", Int J Oral Maxillofac Implants, 7, pp.302~310 (1992)
- Ivanoff CJ, "Histologic evaluation of bone response to oxidized and turned titanium micro-implants in human jawbone", Int J Oral Maxillofac Implants, 18, pp.341~348 (2003)
- Hsu SH, "Characterization and biocompatibility of a titanium dental implant with a laser irradiated and dual-acid etched surface", Biomed Mater Eng, 17, pp.53~68 (2007)
- Trisi P, "A histometric comparison of smooth and rough titanium implants in human low-density jawbone", Int J Oral Maxillofac Implants, 14, pp.689~698 (1999)
- Grossner-Schreiber B, "Modified implant surfaces show different biofilm compositions under in vivo conditions", Clin Oral Implants Res, 20, pp.817~826 (2009)
- Drake DR, "Primary bacterial colonization of implant surfaces", Int J Oral Maxillofac Implants, 14, pp.226~232 (1999)
- Renvert S, "Non-surgical treatment of peri-implant mucositis and peri-implantitis: a literature review", J Clin Periodontol, 35(8), pp.305~315 (2008)
- Maximo MB, "Short-term clinical and microbiological evaluations of peri-implant diseases before and after mechanical anti-infective therapies", Clin Oral Implants Res, 20, pp.99~108 (2009)
- Kreisler M, "Effect of Nd:YAG, Ho: YAG, Er:YAG, CO2, and GaAIAs laser irradiation on surface properties of endosseous dental implants", Int J Oral Maxillofac Implants, 17, pp.202~211 (2002)
- Kreisler M, "Bactericidal effect of the Er:YAG laser on dental implant surfaces: an in vitro study", J Periodontol, 73, pp.1292~1298 (2002)
- Folwaczny M, "Antimicrobial effects of 2.94 microm Er:YAG laser radiation on root surfaces: an in vitro study", J Clin Periodontol, 29, pp.73~78 (2002)
- Friedmann A, "In vitro attachment of osteoblasts on contaminated rough titanium surfaces treated by Er:YAG laser", J Biomed Mater Res A, 79, pp.53~60 (2006)
- Schwarz F, "In vivo effects of an Er:YAG laser, an ultrasonic system and scaling and root planing on the biocompatibility of periodontally diseased root surfaces in cultures of human PDL fibroblasts", Lasers Surg Med, 33, pp.140~147 (2003)
- Kreisler M, "In vitro evaluation of the biocompatibility of contaminated implant surfaces treated with an Er: YAG laser and an air powder system", Clin Oral Implants Res, 16, pp.36~43 (2005)
- "Bone and soft tissue integration to titanium implants with different surface topography: an experimental study in the dog", Int J Oral Maxillofac Implants, 16, pp.323~332 (2001)
- 설영택, "Which surface properties enhance bone response to implants? Comparison of oxidized magnesium, TiUnite, and osseotite implant surfaces", INTERNATIONAL JOURNAL OF PROSTHODONTICS, 19(4), pp.319~328 (2006), QUINTESSENCE PUBLISHING CO INC
- 설영택, "Surface characteristics of electrochemically oxidized implants and acid-etched implants: Surface chemistry, morphology, pore configurations, oxide thickness, crystal structure, and roughness", INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 23, pp.631~640, Quintessence Publishing Company
- Lang NP, "Working Group 4. Implant surfaces and design (Working Group 4)", Clin Oral Implants Res, 20(4), pp.228~231 (2009)
- Wennerberg A, "Bone tissue response to commercially pure titanium implants blasted with fine and coarse particles of aluminum oxide", Int J Oral Maxillofac Implants, 11, pp.38~45 (1996)
- 정도민, "염산 테트라싸이클린이 이중 산부식 임플란트 표면 구조에 미치는 영향", Journal of Periodontal & Implant Science, 37(2), pp.265~275 (2007), 대한치주과학회