본문 바로가기
KERD
논문KCI 등재

The effect of erbium-doped: yttrium, aluminium and garnet laser irradiation on the surface microstructure and roughness of double acidetched implants

2

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류치의학

초록

Purpose: One of the most frequent complications related to dental implants is peri-implantitis, and the characteristics of implant surfaces are closely related to the progression and resolution of inflammation. Therefore, a technical modality that can effectively detoxify the implant surface without modification to the surface is needed. The purpose of this study was to evaluate the effect of erbium-doped: yttrium, aluminium and garnet (Er:YAG) laser irradiation on the microstructural changes in double acid-etched implant surfaces according to the laser energy and the application duration. Methods: The implant surface was irradiated using an Er:YAG laser with different application energy levels (100 mJ/pulse, 140mJ/pulse, and 180 mJ/pulse) and time periods (1 minute, 1.5 minutes, and 2 minutes). We then examined the change in surface roughness value and microstructure. Results: In a scanning electron microscopy evaluation, the double acid-etched implant surface was not altered by Er:YAG laser irradiation under the condition of 100 mJ/pulse at 10 Hz for any of the irradiation times. However, we investigated the reduced sharpness of the specific ridge microstructure that resulted under the 140 mJ/pulse and 180 mJ/pulse conditions. The reduction in sharpness became more severe as laser energy and application duration increased. In the roughness measurement,the double acid-etched implants showed a low roughness value on the valley area before the laser irradiation. Under all experimental conditions, Er:YAG laser irradiation led to a minor decrease in surface roughness, which was not statistically significant. Conclusions: The recommended application settings for Er:YAG laser irradiation on double acid-etched implant surface is less than a 100 mJ/pulse at 10 Hz, and for less than two minutes in order to detoxify the implant surface without causing surface modification.

Abstract

Purpose: One of the most frequent complications related to dental implants is peri-implantitis, and the characteristics of implant surfaces are closely related to the progression and resolution of inflammation. Therefore, a technical modality that can effectively detoxify the implant surface without modification to the surface is needed. The purpose of this study was to evaluate the effect of erbium-doped: yttrium, aluminium and garnet (Er:YAG) laser irradiation on the microstructural changes in double acid-etched implant surfaces according to the laser energy and the application duration. Methods: The implant surface was irradiated using an Er:YAG laser with different application energy levels (100 mJ/pulse, 140mJ/pulse, and 180 mJ/pulse) and time periods (1 minute, 1.5 minutes, and 2 minutes). We then examined the change in surface roughness value and microstructure. Results: In a scanning electron microscopy evaluation, the double acid-etched implant surface was not altered by Er:YAG laser irradiation under the condition of 100 mJ/pulse at 10 Hz for any of the irradiation times. However, we investigated the reduced sharpness of the specific ridge microstructure that resulted under the 140 mJ/pulse and 180 mJ/pulse conditions. The reduction in sharpness became more severe as laser energy and application duration increased. In the roughness measurement,the double acid-etched implants showed a low roughness value on the valley area before the laser irradiation. Under all experimental conditions, Er:YAG laser irradiation led to a minor decrease in surface roughness, which was not statistically significant. Conclusions: The recommended application settings for Er:YAG laser irradiation on double acid-etched implant surface is less than a 100 mJ/pulse at 10 Hz, and for less than two minutes in order to detoxify the implant surface without causing surface modification.

참고문헌 (39)

  1. Albrektsson TO, "Biological aspects of implant dentistry: osseointegration", Periodontol 2000, 4, pp.58~73 (1994)
  2. Mombelli A, "The diagnosis and treatment of peri-implantitis", Periodontol 2000, 17, pp.63~76 (1998)
  3. Quirynen M, "A study of 589 consecutive implants supporting complete fixed prostheses. Part I: Periodontal aspects", J Prosthet Dent, 68, pp.655~663 (1992)
  4. Isidor F, "Loss of osseointegration caused by occlusal load of oral implants. A clinical and radiographic study in monkeys", Clin Oral Implants Res, 7, pp.143~152 (1996)
  5. Pongnarisorn NJ, "Inflammation associated with implants with different surface types", Clin Oral Implants Res, 18, pp.114~125 (2007)
  6. Meffert RM, "Dental implants: a review", J Periodontol, 63, pp.859~870 (1992)
  7. Mombelli A, "Microbiology and antimicrobial therapy of peri-implantitis", Periodontol 2000, 28, pp.177~189 (2002)
  8. Krozer A, "Chemical treatment of machined titanium surfaces. An in vitro study", Clin Oral Implants Res, 10, pp.204~211 (1999)
  9. Schwarz F, "Effect of an Er:YAG laser on periodontally involved root surfaces: an in vivo and in vitro SEM comparison", Lasers Surg Med, 29, pp.328~335 (2001)
  10. Schwarz F, "In vivo and in vitro effects of an Er:YAG laser, a GaAlAs diode laser, and scaling and root planing on periodontally diseased root surfaces: a comparative histologic study", Lasers Surg Med, 32, pp.359~366 (2003)
  11. Ando Y, "Bactericidal effect of erbium YAG laser on periodontopathic bacteria", Lasers Surg Med, 19, pp.190~200 (1996)
  12. Yamaguchi H, "Effects of irradiation of an erbium:YAG laser on root surfaces", J Periodontol, 68, pp.1151~1155 (1997)
  13. Matsuyama T, "Effects of the Er:YAG laser irradiation on titanium implant materials and contaminated implant abutment surfaces", J Clin Laser Med Surg, 21, pp.7~17 (2003)
  14. Albrektsson T, "Oral implant surfaces: Part 1--review focusing on topographic and chemical properties of different surfaces and in vivo responses to them", Int J Prosthodont, 17, pp.536~543 (2004)
  15. De Leonardis D, "Osseointegration of rough acid-etched titanium implants: 5-year follow-up of 100 minimatic implants", Int J Oral Maxillofac Implants, 14, pp.384~391 (1999)
  16. Wennerberg A, "A 1-year follow-up of implants of differing surface roughness placed in rabbit bone", Int J Oral Maxillofac Implants 1997, 12, pp.486~494 (1997)
  17. Lazzara RJ, "A hu man histologic analysis of osseotite and machined surfaces using implants with 2 opposing surfaces", Int J Periodontics Restorative Dent, 19, pp.117~129 (1999)
  18. London RM, "Histologic comparison of a thermal dual-etched implant surface to machined, TPS, and HA surfaces: bone contact in vivo in rabbits", Int J Oral Maxillofac Implants, 17, pp.369~376 (2002)
  19. Park JY, "Red blood cell and platelet interactions with titanium implant surfaces", Clin Oral Implants Res, 11, pp.530~539 (2000)
  20. Bowers KT, "Optimization of surface micromorphology for enhanced osteoblast responses in vitro", Int J Oral Maxillofac Implants, 7, pp.302~310 (1992)
  21. Ivanoff CJ, "Histologic evaluation of bone response to oxidized and turned titanium micro-implants in human jawbone", Int J Oral Maxillofac Implants, 18, pp.341~348 (2003)
  22. Hsu SH, "Characterization and biocompatibility of a titanium dental implant with a laser irradiated and dual-acid etched surface", Biomed Mater Eng, 17, pp.53~68 (2007)
  23. Trisi P, "A histometric comparison of smooth and rough titanium implants in human low-density jawbone", Int J Oral Maxillofac Implants, 14, pp.689~698 (1999)
  24. Grossner-Schreiber B, "Modified implant surfaces show different biofilm compositions under in vivo conditions", Clin Oral Implants Res, 20, pp.817~826 (2009)
  25. Drake DR, "Primary bacterial colonization of implant surfaces", Int J Oral Maxillofac Implants, 14, pp.226~232 (1999)
  26. Renvert S, "Non-surgical treatment of peri-implant mucositis and peri-implantitis: a literature review", J Clin Periodontol, 35(8), pp.305~315 (2008)
  27. Maximo MB, "Short-term clinical and microbiological evaluations of peri-implant diseases before and after mechanical anti-infective therapies", Clin Oral Implants Res, 20, pp.99~108 (2009)
  28. Kreisler M, "Effect of Nd:YAG, Ho: YAG, Er:YAG, CO2, and GaAIAs laser irradiation on surface properties of endosseous dental implants", Int J Oral Maxillofac Implants, 17, pp.202~211 (2002)
  29. Kreisler M, "Bactericidal effect of the Er:YAG laser on dental implant surfaces: an in vitro study", J Periodontol, 73, pp.1292~1298 (2002)
  30. Folwaczny M, "Antimicrobial effects of 2.94 microm Er:YAG laser radiation on root surfaces: an in vitro study", J Clin Periodontol, 29, pp.73~78 (2002)
  31. Friedmann A, "In vitro attachment of osteoblasts on contaminated rough titanium surfaces treated by Er:YAG laser", J Biomed Mater Res A, 79, pp.53~60 (2006)
  32. Schwarz F, "In vivo effects of an Er:YAG laser, an ultrasonic system and scaling and root planing on the biocompatibility of periodontally diseased root surfaces in cultures of human PDL fibroblasts", Lasers Surg Med, 33, pp.140~147 (2003)
  33. Kreisler M, "In vitro evaluation of the biocompatibility of contaminated implant surfaces treated with an Er: YAG laser and an air powder system", Clin Oral Implants Res, 16, pp.36~43 (2005)
  34. "Bone and soft tissue integration to titanium implants with different surface topography: an experimental study in the dog", Int J Oral Maxillofac Implants, 16, pp.323~332 (2001)
  35. 설영택, "Which surface properties enhance bone response to implants? Comparison of oxidized magnesium, TiUnite, and osseotite implant surfaces", INTERNATIONAL JOURNAL OF PROSTHODONTICS, 19(4), pp.319~328 (2006), QUINTESSENCE PUBLISHING CO INC
  36. 설영택, "Surface characteristics of electrochemically oxidized implants and acid-etched implants: Surface chemistry, morphology, pore configurations, oxide thickness, crystal structure, and roughness", INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 23, pp.631~640, Quintessence Publishing Company
  37. Lang NP, "Working Group 4. Implant surfaces and design (Working Group 4)", Clin Oral Implants Res, 20(4), pp.228~231 (2009)
  38. Wennerberg A, "Bone tissue response to commercially pure titanium implants blasted with fine and coarse particles of aluminum oxide", Int J Oral Maxillofac Implants, 11, pp.38~45 (1996)
  39. 정도민, "염산 테트라싸이클린이 이중 산부식 임플란트 표면 구조에 미치는 영향", Journal of Periodontal & Implant Science, 37(2), pp.265~275 (2007), 대한치주과학회

관련 논문AI추천