Load response of the natural tooth and dental implant: A comparative biomechanics study
2
조회
0
다운로드
2
인용
0
참고문헌
키워드
초록
PURPOSE. While dental implants have displayed high success rates, poor mechanical fixation is a common complication, and their biomechanical response to occlusal loading remains poorly understood. This study aimed to develop and validate a computational model of a natural first premolar and a dental implant with matching crown morphology, and quantify their mechanical response to loading at the occlusal surface. MATERIALS AND METHODS. A finite-element model of the stomatognathic system comprising the mandible, first premolar and periodontal ligament (PDL) was developed based on a natural human tooth, and a model of a dental implant of identical occlusal geometry was also created. Occlusal loading was simulated using point forces applied at seven landmarks on each crown. Model predictions were validated using strain gauge measurements acquired during loading of matched physical models of the tooth and implant assemblies. RESULTS. For the natural tooth, the maximum von-Mises stress (6.4 MPa) and maximal principal strains at the mandible (1.8 mε, -1.7 mε) were lower than those observed at the prosthetic tooth (12.5 MPa, 3.2 mε, and –4.4 mε, respectively). As occlusal load was applied more bucally relative to the tooth central axis, stress and strain magnitudes increased. CONCLUSION. Occlusal loading of the natural tooth results in lower stress-strain magnitudes in the underlying alveolar bone than those associated with a dental implant of matched occlusal anatomy. The PDL may function to mitigate axial and bending stress intensities resulting from off-centered occlusal loads. The findings may be useful in dental implant design, restoration material selection, and surgical planning.
Abstract
PURPOSE. While dental implants have displayed high success rates, poor mechanical fixation is a common complication, and their biomechanical response to occlusal loading remains poorly understood. This study aimed to develop and validate a computational model of a natural first premolar and a dental implant with matching crown morphology, and quantify their mechanical response to loading at the occlusal surface. MATERIALS AND METHODS. A finite-element model of the stomatognathic system comprising the mandible, first premolar and periodontal ligament (PDL) was developed based on a natural human tooth, and a model of a dental implant of identical occlusal geometry was also created. Occlusal loading was simulated using point forces applied at seven landmarks on each crown. Model predictions were validated using strain gauge measurements acquired during loading of matched physical models of the tooth and implant assemblies. RESULTS. For the natural tooth, the maximum von-Mises stress (6.4 MPa) and maximal principal strains at the mandible (1.8 mε, -1.7 mε) were lower than those observed at the prosthetic tooth (12.5 MPa, 3.2 mε, and –4.4 mε, respectively). As occlusal load was applied more bucally relative to the tooth central axis, stress and strain magnitudes increased. CONCLUSION. Occlusal loading of the natural tooth results in lower stress-strain magnitudes in the underlying alveolar bone than those associated with a dental implant of matched occlusal anatomy. The PDL may function to mitigate axial and bending stress intensities resulting from off-centered occlusal loads. The findings may be useful in dental implant design, restoration material selection, and surgical planning.
참고문헌 (40)
- Moraschini V, "Evaluation of survival and success rates of dental implants reported in longitudinal studies with a follow-up period of at least 10 years : a systematic review", Int J Oral Maxillofac Surg, 44, pp.377~388 (2015)
- Pjetursson BE, "Improvements in implant dentistry over the last decade : comparison of survival and complication rates in older and newer publications", Int J Oral Maxillofac Implants, 29, pp.308~324 (2014)
- Jung RE, "A systematic review of the 5-year survival and complication rates of implant-supported single crowns", Clin Oral Implants Res, 19, pp.119~130 (2008)
- Esposito M, "Biological factors contributing to failures of osseointegrated oral implants. (I). Success criteria and epidemiology", Eur J Oral Sci, 106, pp.527~551 (1998)
- Esposito M, "Biological factors contributing to failures of osseointegrated oral implants. (II). Etiopathogenesis", Eur J Oral Sci, 106, pp.721~764 (1998)
- Pye AD, "A review of dental implants and infection", J Hosp Infect, 72, pp.104~110 (2009)
- Misch CE, "Implant success, survival, and failure:the International Congress of Oral Implantologists (ICOI) Pisa Consensus Conference", Implant Dent, 17, pp.5~15 (2008)
- Eskitascioglu G, "The influence of occlusal loading location on stresses transferred to implant-supported prostheses and supporting bone : A three-dimensional finite element study", J Prosthet Dent, 91, pp.144~150 (2004)
- Sevimay M, "Three-dimensional finite element analysis of the effect of different bone quality on stress distribution in an implant-supported crown", J Prosthet Dent, 93, pp.227~234 (2005)
- Soncini M, "Experimental procedure for the evaluation of the mechanical properties of the bone surrounding dental implants", Biomaterials, 23, pp.9~17 (2002)
- Geng JP, "Application of finite element analysis in implant dentistry : a review of the literature", J Prosthet Dent, 85, pp.585~598 (2001)
- Lin CL, "Multi-factorial analysis of variables influencing the bone loss of an implant placed in the maxilla : prediction using FEA and SED bone remodeling algorithm", J Biomech, 43, pp.644~651 (2010)
- de Las Casas EB, "Determination of tangential and normal components of oral forces", J Appl Oral Sci, 15, pp.70~76 (2007)
- Du J, "Biomechanics and strain mapping in bone as related to immediately-loaded dental implants", J Biomech, 48, pp.3486~3494 (2015)
- Chee WW, "Tooth-to-implant connection : a systematic review of the literature and a case report utilizing a new connection design", Clin Implant Dent Relat Res, 12, pp.122~133 (2010)
- Fill TS, "Experimentally determined mechanical properties of, and models for, the periodontal ligament : critical review of current literature", J Dent Biomech, 2011, pp.312980~ (2011)
- Melsen B, "Biological reaction of alveolar bone to orthodontic tooth movement", Angle Orthod, 69, pp.151~158 (1999)
- Cattaneo PM, "Strains in periodontal ligament and alveolar bone associated with orthodontic tooth movement analyzed by finite element", Orthod Craniofac Res, 12, pp.120~128 (2009)
- Brunski JB, "In vivo bone response to biomechanical loading at the bone", dental-implant interface, 1999, pp.13, 99~119
- Taddei F, "Subject-specific finite element models of long bones : An in vitro evaluation of the overall accuracy", J Biomech, 39, pp.2457~2467 (2006)
- Morneburg TR, "In vivo forces on implants influenced by occlusal scheme and food consistency", Int J Prosthodont, 16, pp.481~486 (2003)
- Stanford CM, "Toward an understanding of implant occlusion and strain adaptive bone modeling and remodeling", J Prosthet Dent, 81, pp.553~561 (1999)
- Ogawa T, "The relationship between inclination of the occlusal plane and jaw closing path", J Prosthet Dent, 76, pp.576~580 (1996)
- Ogawa T, "Characteristics of masticatory movement in relation to inclination of occlusal plane", J Oral Rehabil, 24, pp.652~657 (1997)
- Martos J, "Morphologic analysis of the root apex in human teeth", J Endod, 36, pp.664~667 (2010)
- Álvarez-Arenal Á, "Stress distribution in the transitional peri-implant bone in a single implant-supported prosthesis with platform-switching under different angulated loads", Odontology, 105, pp.68~75 (2017)
- Cheng HC, "Influence of deformation and stress between bone and implant from various bite forces by numerical simulation analysis", Biomed Res Int, 2017, pp.2827953~ (2017)
- Weinberg LA, "Reduction of implant loading using a modified centric occlusal anatomy", Int J Prosthodont, 11, pp.55~69 (1998)
- Weinberg LA, "Therapeutic biomechanics concepts and clinical procedures to reduce implant loading. Part I", J Oral Implantol, 27, pp.293~301 (2001)
- Katona TR, "The mechanics of dental occlusion and disclusion", Clin Biomech(Bristol, Avon), 50, pp.84~91 (2017)
- Sheridan RA, "The role of occlusion in implant therapy : A comprehensive updated review", Implant Dent, 25, pp.829~838 (2016)
- Abichandani SJ, "Implant protected occlusion : A comprehensive review", Eur J Prosthodont, 1, pp.29~36 (2013)
- Kim Y, "Occlusal considerations in implant therapy : clinical guidelines with biomechanical rationale", Clin Oral Implants Res, 16, pp.26~35 (2005)
- Jennifer Lo, "Effect of different lateral occlusion schemes on peri-implant strain: A laboratory study", The Journal of Advanced of Prosthodontics, 9(1), pp.45~51 (2017), 대한치과보철학회[DOI]
- Taylor TD, "Prosthodontic considerations", Clin Oral Implants Res, 11, pp.101~107 (2000)
- Chen YY, "Implant occlusion : biomechanical considerations for implant-supported prostheses", J Dent Sci, 3, pp.65~74 (2008)
- Rungsiyakull P, "Loading of a single implant in simulated bone", Int J Prosthodont, 24, pp.140~143 (2011)
- Koyano K, "Occlusion on oral implants : current clinical guidelines", J Oral Rehabil, 42, pp.153~161 (2015)
- Röhrle O, "A novel computational method to determine subject-specific bite force and occlusal loading during mastication", Comput Methods Biomech Biomed Engin, 21, pp.453~460 (2018)
- Giesen EBW, "Mechanical properties of cancellous bone in the human mandibular condyle are anisotropic", J Biomech, 34, pp.799~803 (2001)
