Effect of different tooth preparation designs on the marginal and internal fit discrepancies of cobalt-chromium crowns produced by computer-aided designing and selective laser melting processes
2
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
PURPOSE. To evaluate the impact of five different tooth preparation designs on the marginal and internal fit discrepancies of cobalt-chromium (CoCr) crowns produced by computer-aided designing (CAD) and selective laser melting (SLM) processes. MATERIALS AND METHODS. Five preparation data were constructed, after which design crowns were obtained. Actual crowns were fabricated using an SLM process. After the data of actual crowns were obtained with structural light scanning, intaglio surfaces of the design crown and actual crown were virtually superimposed on the preparation. The fit-discrepancies were displayed with colors, while the root means square was calculated and analyzed with one-way analysis of variance (ANOVA), Tukey’s test or Kruskal-Wallis test (α = .05). RESULTS. The marginal or internal color-coded images in the five design groups were not identical. The shoulder-lip and sharp line angle groups in the CAD or SLM process had larger marginal or internal fit discrepancies compared to other groups (P < .05). In the CAD process, the mean marginal and internal fit discrepancies were 10.0 to 24.2 μm and 29.6 to 31.4 μm, respectively. After the CAD and SLM processes, the mean marginal and internal fit discrepancies were 18.4 to 40.9 μm and 39.1 to 47.1 μm, respectively. The SLM process itself resulted in a positive increase of the marginal (6.0 - 16.7 μm) and internal (9.0 - 15.7 μm) fit discrepancies. CONCLUSION. The CAD and SLM processes affected the fit of CoCr crowns and varied based on the preparation designs. Typically, the shoulder-lip and sharp line angle designs had a more significant effect on crown fit. However, the differences between the design groups were relatively small, especially when compared to fit discrepancies observed clinically.
Abstract
PURPOSE. To evaluate the impact of five different tooth preparation designs on the marginal and internal fit discrepancies of cobalt-chromium (CoCr) crowns produced by computer-aided designing (CAD) and selective laser melting (SLM) processes. MATERIALS AND METHODS. Five preparation data were constructed, after which design crowns were obtained. Actual crowns were fabricated using an SLM process. After the data of actual crowns were obtained with structural light scanning, intaglio surfaces of the design crown and actual crown were virtually superimposed on the preparation. The fit-discrepancies were displayed with colors, while the root means square was calculated and analyzed with one-way analysis of variance (ANOVA), Tukey’s test or Kruskal-Wallis test (α = .05). RESULTS. The marginal or internal color-coded images in the five design groups were not identical. The shoulder-lip and sharp line angle groups in the CAD or SLM process had larger marginal or internal fit discrepancies compared to other groups (P < .05). In the CAD process, the mean marginal and internal fit discrepancies were 10.0 to 24.2 μm and 29.6 to 31.4 μm, respectively. After the CAD and SLM processes, the mean marginal and internal fit discrepancies were 18.4 to 40.9 μm and 39.1 to 47.1 μm, respectively. The SLM process itself resulted in a positive increase of the marginal (6.0 - 16.7 μm) and internal (9.0 - 15.7 μm) fit discrepancies. CONCLUSION. The CAD and SLM processes affected the fit of CoCr crowns and varied based on the preparation designs. Typically, the shoulder-lip and sharp line angle designs had a more significant effect on crown fit. However, the differences between the design groups were relatively small, especially when compared to fit discrepancies observed clinically.
참고문헌 (40)
- Tamac E, "Clinical marginal and internal adaptation of CAD", CAM milling, laser sintering, and cast metal ceramic crowns, 2014, pp.112, 909~913
- Zeng L, "Effects of repeated firing on the marginal accuracy of Co-Cr copings fabricated by selective laser melting", J Prosthet Dent, 113, pp.135~139 (2015)
- Hong MH, "Marginal fit of metal-ceramic crowns fabricated by using a casting and two selective laser melting processes before and after ceramic firing", J Prosthet Dent, 122, pp.475~481 (2019)
- Kocaağaoğlu H, "In vitro evaluation of marginal, axial, and occlusal discrepancies in metal ceramic restorations produced with new technologies", J Prosthet Dent, 116, pp.368~374 (2016)
- Koutsoukis T, "Selective laser melting technique of co-cr dental alloys : a review of structure and properties and comparative analysis with other available techniques", J Prosthodont, 24, pp.303~312 (2015)
- Yang X, "Effect of fluoride content on ion release from cast and selective laser melting-processed Co-Cr-Mo alloys", J Prosthet Dent, 112, pp.1212~1216 (2014)
- Zeng L, "A comparison of corrosion resistance of cobalt-chromium-molybdenum metal ceramic alloy fabricated with selective laser melting and traditional processing", J Prosthet Dent, 112, pp.1217~1224 (2014)
- Kokubo Y, "Clinical marginal and internal gaps of Procera AllCeram crowns", J Oral Rehabil, 32, pp.526~530 (2005)
- Sakrana AA, "In vitro evaluation of the marginal and internal discrepancies of different esthetic restorations", J Appl Oral Sci, 21, pp.575~580 (2013)
- Zimmermann M, "Three-dimensional digital evaluation of the fit of endocrowns fabricated from different CAD", CAM materials, 2019, pp.28, e504~e509
- van Noort R, "The future of dental devices is digital", Dent Mater, 28, pp.3~12 (2012)
- Raigrodski AJ, "Contemporary materials and technologies for all-ceramic fixed partial dentures : a review of the literature", J Prosthet Dent, 92, pp.557~562 (2004)
- Schaefer O, "Effect of CNC-milling on the marginal and internal fit of dental ceramics : a pilot study", Dent Mater, 29, pp.851~858 (2013)
- Nesse H, "Internal and marginal fit of cobalt-chromium fixed dental prostheses fabricated with 3 different techniques", J Prosthet Dent, 114, pp.686~692 (2015)
- Akçin ET, "Effect of manufacturing techniques on the marginal and internal fit of cobalt-chromium implant-supported multiunit frameworks", J Prosthet Dent, 120, pp.715~720 (2018)
- Nadine Freifrau von Maltzahn, "Fitting accuracy of ceramic veneered Co-Cr crowns produced by different manufacturing processes", The Journal of Advanced of Prosthodontics, 12(2), pp.100~106 (2020), 대한치과보철학회[DOI]
- Kim DY, "Evaluation of fits of metal copings fabricated by using selective laser melting at various angles", J Prosthet Dent (2021)
- Seymour KG, "Metal ceramic crowns-a review of tooth preparation", Eur J Prosthodont Restor Dent, 7, pp.79~84 (1999)
- Shiratsuchi H, "Influence of finish line design on marginal adaptation of electroformed metal-ceramic crowns", J Prosthet Dent, 95, pp.237~242 (2006)
- Renne W, "Predicting marginal fit of CAD", CAM crowns based on the presence or absence of common preparation errors, 2012, pp.108, 310~315
- Al Maaz A, "Effect of finish line design and metal alloy on the marginal and internal gaps of selective laser melting printed copings", J Prosthet Dent, 122, pp.143~151 (2019)
- Podhorsky A, "Tooth preparation for full-coverage restorations-a literature review", Clin Oral Investig, 19, pp.959~968 (2015)
- Yu H, "Finish-line designs for ceramic crowns : a systematic review and meta-analysis", J Prosthet Dent, 122, pp.22~30.e5 (2019)
- Tan FB, "Titanium clasp fabricated by selective laser melting, CNC milling, and conventional casting: a comparative in vitro study", J Prosthodont Res, 63, pp.58~65 (2019)
- Huang Z, "Clinical marginal and internal fit of metal ceramic crowns fabricated with a selective laser melting technology", J Prosthet Dent, 113, pp.623~627 (2015)
- Schönberger J, "Marginal and internal fit of posterior three-unit fixed zirconia dental prostheses fabricated with two different CAD", CAM systems and materials, 2017, pp.21, 2629~2635
- Ortega R, "SEM evaluation of the precision of fit of CAD", CAM zirconia and metal-ceramic posterior crowns, 2017, pp.36, 387~393
- Neves FD, "Micro-computed tomography evaluation of marginal fit of lithium disilicate crowns fabricated by using chairside CAD", CAM systems or the heat-pressing technique, 2014, pp.112, 1134~1140
- Gurel K, "In vitro marginal and internal adaptation of metal-ceramic crowns with cobalt-chrome and titanium framework fabricated with CAD", CAM and casting technique, 2019, pp.22, 812~816
- Kim JH, "Influence of various gypsum materials on precision of fit of CAD", CAM-fabricated zirconia copings, 2015, pp.34, 19~24
- Zheng SX, "Extraction of the borderline in Prepared tooth cavity based on intelligent scissors", The 2nd iCBBE, pp.680~683 (2008)
- Zhang B, "The extraction method of tooth preparation margin line based on S-Octree CNN", Int J Numer Method Biomed Eng, 35, pp.e3241~ (2019)
- "Zhonghua Kou Qiang Yi Xue Za Zhi", 2013, 550~553
- Morgan D, "Support structure development and initial results for metal powder bed fusion additive manufacturing", Procedia Manuf, 10, pp.819~830 (2017)
- Adam GAO, "Design for additive manufacturing-element transitions and aggregated structures", CIRP J Manuf Sci Technol, 7, pp.20~28 (2014)
- Yang X, "Study on dimensional accuracy of typical geometric features manufactured by selective laser melting", Zhongguo Jiguang, 2015, pp.42, ~
- Soares CJ, "Influence of cavity preparation design on fracture resistance of posterior Leucite-reinforced ceramic restorations", J Prosthet Dent, 95, pp.421~429 (2006)
- Beuer F, "Precision of fit : zirconia three-unit fixed dental prostheses", Clin Oral Investig, 13, pp.343~349 (2009)
- Papadiochou S, "Marginal adaptation and CAD-CAM technology : a systematic review of restorative material and fabrication techniques", J Prosthet Dent, 119, pp.545~551 (2018)
- Mou SH, "Influence of different convergence angles and tooth preparation heights on the internal adaptation of Cerec crowns", J Prosthet Dent, 87, pp.248~255 (2002)