PURPOSE. The present study aims to analyze the effect of abutment neck taper and types of cement on the amount of undetected remnant cement of cementretained implant prostheses. MATERIALS AND METHODS. Three neck taper angles (53°, 65°, 77°) and three types of cement (RMGI: resin-modified glass ionomer, ZPC: zinc phosphate cement, ZOE: zinc oxide eugenol cement) were used. For each group, the surface percentage was measured using digital image and graphic editing software. The weight of before and after removing remnant cement from the abutment-crown assembly was measured using an electronic scale. Two-way ANOVA and Duncan & Scheffe’s test were used to compare the calculated surface percentage and weight of remnant cement (α = .05). RESULTS. There were significant differences in remnant cement surface percentage and weight according to neck taper angles (P < .05). However, there were no significant differences in remnant cement surface percentage and weight on types of cement. No interaction was found between neck taper angles and types of luting cement (P > .05). The wide abutment with a small neck taper angle showed the most significant amount of remnant cement. And the types of luting cement did not influence the amount of residual cement. CONCLUSION. To remove excess cement better, the emergence profile of the crown should be straight to the neck taper of the abutment in cement-retained implant restoration.

Abstract

PURPOSE. The present study aims to analyze the effect of abutment neck taper and types of cement on the amount of undetected remnant cement of cementretained implant prostheses. MATERIALS AND METHODS. Three neck taper angles (53°, 65°, 77°) and three types of cement (RMGI: resin-modified glass ionomer, ZPC: zinc phosphate cement, ZOE: zinc oxide eugenol cement) were used. For each group, the surface percentage was measured using digital image and graphic editing software. The weight of before and after removing remnant cement from the abutment-crown assembly was measured using an electronic scale. Two-way ANOVA and Duncan & Scheffe’s test were used to compare the calculated surface percentage and weight of remnant cement (α = .05). RESULTS. There were significant differences in remnant cement surface percentage and weight according to neck taper angles (P < .05). However, there were no significant differences in remnant cement surface percentage and weight on types of cement. No interaction was found between neck taper angles and types of luting cement (P > .05). The wide abutment with a small neck taper angle showed the most significant amount of remnant cement. And the types of luting cement did not influence the amount of residual cement. CONCLUSION. To remove excess cement better, the emergence profile of the crown should be straight to the neck taper of the abutment in cement-retained implant restoration.

참고문헌 (33)

  1. Roos-Jansåker AM, "Long time follow up of implant therapy and treatment of peri-implantitis", Swed Dent J Suppl, (188), pp.7~66 (2007)
  2. Behr M, "The extent of luting agent remnants on titanium and zirconia abutment analogs after scaling", Int J Oral Maxillofac Implants, 29, pp.1185~1192 (2014)
  3. Papaspyridakos P, "Success criteria in implant dentistry : a systematic review", J Dent Res, 91, pp.242~248 (2012)
  4. Goldberg PV, "Periodontal considerations in restorative and implant therapy", Periodontol 2000, 25, pp.100~109 (2001)
  5. Parpaiola A, "Managing the peri-implant mucosa : a clinically reliable method for optimizing soft tissue contours and emergence profile", J Esthet Restor Dent, 25, pp.317~323 (2013)
  6. Michalakis KX, "Cement-retained versus screw-retained implant restorations : a critical review", Int J Oral Maxillofac Implants, 18, pp.719~728 (2003)
  7. Levine RA, "Complications with excess cement & dental implants: diagnosis, recommendations & treatment of 7 clinical cases", Implant Realities, 1, pp.51~59 (2014)
  8. Agar JR, "Cement removal from restorations luted to titanium abutments with simulated subgingival margins", J Prosthet Dent, 78, pp.43~47 (1997)
  9. Pauletto N, "Complications associated with excess cement around crowns on osseointegrated implants : a clinical report", Int J Oral Maxillofac Implants, 14, pp.865~868 (1999)
  10. Gapski R, "Endosseous implant failure influenced by crown cementation : a clinical case report", Int J Oral Maxillofac Implants, 23, pp.943~946 (2008)
  11. Rajan M, "Fabrication of a cement-and screw-retained implant prosthesis", J Prosthet Dent, 92, pp.578~580 (2004)
  12. Heo YK, "A newly designed screw-and cement-retained prosthesis and its abutments", Int J Prosthodont, 28, pp.612~614 (2015)
  13. Andersson M, "Accuracy of machine milling and spark erosion with a CAD", CAM system, 1996, pp.76, 187~193
  14. Priest G, "Virtual-designed and computer-milled implant abutments", J Oral Maxillofac Surg, 63, pp.22~32 (2005)
  15. Jemt T, "A comparison of laser-welded titanium and conventional cast frameworks supported by implants in the partially edentulous jaw : a 3-year prospective multicenter study", Int J Prosthodont, 13, pp.282~288 (2000)
  16. Kappel S, "Undetected residual cement on standard or individualized all-ceramic abutments with cemented zirconia single crowns-a prospective randomized pilot trial", Clin Oral Implants Res, 27, pp.1065~1071 (2016)
  17. Linkevicius T, "The influence of margin location on the amount of undetected cement excess after delivery of cement-retained implant restorations", Clin Oral Implants Res, 22, pp.1379~1384 (2011)
  18. Kong L, "Selections of the cylinder implant neck taper and implant end fillet for optimal biomechanical properties : a three-dimensional finite element analysis", J Biomech, 41, pp.1124~1130 (2008)
  19. Tarica DY, "Survey of United States dental schools on cementation protocols for implant crown restorations", J Prosthet Dent, 103, pp.68~79 (2010)
  20. Aung SSMP, "Effects of alumina-blasting pressure on the bonding to super", ultra-translucent zirconia, 2019, pp.35, 730~739
  21. Coelho PG, "Fatigue testing of two porcelain-zirconia all-ceramic crown systems", Dent Mater, 25, pp.1122~1127 (2009)
  22. Linkevicius T, "The influence of the cementation margin position on the amount of undetected cement. A prospective clinical study", Clin Oral Implants Res, 24, pp.71~76 (2013)
  23. Berglundh T, "Dimension of the periimplant mucosa. Biological width revisited", J Clin Periodontol, 23, pp.971~973 (1996)
  24. Berglundh T, "The soft tissue barrier at implants and teeth", Clin Oral Implants Res, 2, pp.81~90 (1991)
  25. Berglundh T, "The topography of the vascular systems in the periodontal and peri-implant tissues in the dog", J Clin Periodontol, 21, pp.189~193 (1994)
  26. Vindasiute E, "Clinical factors influencing removal of the cement excess in implant-supported restorations", Clin Implant Dent Relat Res, 17, pp.771~778 (2015)
  27. 김미주, "임플란트 지지 나사-시멘트 유지형 보철물에서 보철물-지대주 제거 후 변연부 연마의 효과: 증례보고", 대한치과보철학회지, 58(3), pp.239~243 (2020), 대한치과보철학회[DOI]
  28. Lee JH, "Influence of Luting materials and methods and the restoration surface on the amount of cement remnants in implant restorations", J Oral Implantol, 45, pp.301~307 (2019)
  29. Galván G, "Cemented implant restoration : A technique for minimizing adverse biologic consequences", J Prosthet Dent, 114, pp.482~485 (2015)
  30. Wadhwani C, "Technique for controlling the cement for an implant crown", J Prosthet Dent, 102, pp.57~58 (2009)
  31. Hess TA, "A technique to eliminate subgingival cement adhesion to implant abutments by using polytetrafluoroethylene tape", J Prosthet Dent, 112, pp.365~368 (2014)
  32. Seo CW, "A technique for minimizing subgingival residual cement by using rubber dam for cement-retained implant crowns", J Prosthet Dent, 117, pp.327~328 (2017)
  33. Korsch M, "Predictors of excess cement and tissue response to fixed implant-supported dentures after cementation", Clin Implant Dent Relat Res, 17, pp.e45~e53 (2015)

관련 논문AI추천

Influence of abutment height and convergence angle on the retrievability of cement-retained implant prostheses with a lingual slot이규복, 이두형, 최규형, 손큰바다대한치과보철학회 · The Journal of Advanced of Prosthodontics2018 · 제10권 제5호Effects of abutment diameter, luting agent type, and re-cementation on the retention of implant-supported CAD/CAM metal copings over short abutmentsFereshteh Hosseini Ghavam, Kaveh Yaghmaei, Parviz Amini, Sina Safari대한치과보철학회 · The Journal of Advanced of Prosthodontics2018 · 제10권 제1호Evaluation of removal forces of implant-supported zirconia copings depending on abutment geometry, luting agent and cleaning method during re-cementationFenja Ehret-Kleinau, Franziska Pohlmeyer, Katharina Lange, Matthias Rödiger, Nikolaus Gersdorff, Ralf Bürgers, Sven Rinke대한치과보철학회 · The Journal of Advanced of Prosthodontics2014 · 제6권 제3호Effect of Indented Structures on the Retention of Cement-Retained Implant-Supported Crowns by Provisional Cement곽재영, 김성균, 박지만, 안진수, 최정훈, 허성주대한구강악안면임플란트학회 · 대한구강악안면임플란트학회지2022 · 제26권 제2호Effect of cement washout on loosening of abutment screws and vice versa in screw- and cement- retained implant-supported dental prosthesis김석규, 손미경, 정재헌대한치과보철학회 · The Journal of Advanced of Prosthodontics2015 · 제7권 제3호Comparative study on stress distribution around internal tapered connection implants according to fit of cement-and screw-retained prostheses박은진, 박지만, 이미영, 허성주대한치과보철학회 · The Journal of Advanced of Prosthodontics2013 · 제5권 제3호

이 간행물의 다른 논문 (5건)