Effect of abutment neck taper and cement types on the amount of remnant cement in cement-retained implant restorations: an in vitro study
2
조회
0
다운로드
1
인용
0
참고문헌
키워드
초록
PURPOSE. The present study aims to analyze the effect of abutment neck taper and types of cement on the amount of undetected remnant cement of cementretained implant prostheses. MATERIALS AND METHODS. Three neck taper angles (53°, 65°, 77°) and three types of cement (RMGI: resin-modified glass ionomer, ZPC: zinc phosphate cement, ZOE: zinc oxide eugenol cement) were used. For each group, the surface percentage was measured using digital image and graphic editing software. The weight of before and after removing remnant cement from the abutment-crown assembly was measured using an electronic scale. Two-way ANOVA and Duncan & Scheffe’s test were used to compare the calculated surface percentage and weight of remnant cement (α = .05). RESULTS. There were significant differences in remnant cement surface percentage and weight according to neck taper angles (P < .05). However, there were no significant differences in remnant cement surface percentage and weight on types of cement. No interaction was found between neck taper angles and types of luting cement (P > .05). The wide abutment with a small neck taper angle showed the most significant amount of remnant cement. And the types of luting cement did not influence the amount of residual cement. CONCLUSION. To remove excess cement better, the emergence profile of the crown should be straight to the neck taper of the abutment in cement-retained implant restoration.
Abstract
PURPOSE. The present study aims to analyze the effect of abutment neck taper and types of cement on the amount of undetected remnant cement of cementretained implant prostheses. MATERIALS AND METHODS. Three neck taper angles (53°, 65°, 77°) and three types of cement (RMGI: resin-modified glass ionomer, ZPC: zinc phosphate cement, ZOE: zinc oxide eugenol cement) were used. For each group, the surface percentage was measured using digital image and graphic editing software. The weight of before and after removing remnant cement from the abutment-crown assembly was measured using an electronic scale. Two-way ANOVA and Duncan & Scheffe’s test were used to compare the calculated surface percentage and weight of remnant cement (α = .05). RESULTS. There were significant differences in remnant cement surface percentage and weight according to neck taper angles (P < .05). However, there were no significant differences in remnant cement surface percentage and weight on types of cement. No interaction was found between neck taper angles and types of luting cement (P > .05). The wide abutment with a small neck taper angle showed the most significant amount of remnant cement. And the types of luting cement did not influence the amount of residual cement. CONCLUSION. To remove excess cement better, the emergence profile of the crown should be straight to the neck taper of the abutment in cement-retained implant restoration.
참고문헌 (33)
- Roos-Jansåker AM, "Long time follow up of implant therapy and treatment of peri-implantitis", Swed Dent J Suppl, (188), pp.7~66 (2007)
- Behr M, "The extent of luting agent remnants on titanium and zirconia abutment analogs after scaling", Int J Oral Maxillofac Implants, 29, pp.1185~1192 (2014)
- Papaspyridakos P, "Success criteria in implant dentistry : a systematic review", J Dent Res, 91, pp.242~248 (2012)
- Goldberg PV, "Periodontal considerations in restorative and implant therapy", Periodontol 2000, 25, pp.100~109 (2001)
- Parpaiola A, "Managing the peri-implant mucosa : a clinically reliable method for optimizing soft tissue contours and emergence profile", J Esthet Restor Dent, 25, pp.317~323 (2013)
- Michalakis KX, "Cement-retained versus screw-retained implant restorations : a critical review", Int J Oral Maxillofac Implants, 18, pp.719~728 (2003)
- Levine RA, "Complications with excess cement & dental implants: diagnosis, recommendations & treatment of 7 clinical cases", Implant Realities, 1, pp.51~59 (2014)
- Agar JR, "Cement removal from restorations luted to titanium abutments with simulated subgingival margins", J Prosthet Dent, 78, pp.43~47 (1997)
- Pauletto N, "Complications associated with excess cement around crowns on osseointegrated implants : a clinical report", Int J Oral Maxillofac Implants, 14, pp.865~868 (1999)
- Gapski R, "Endosseous implant failure influenced by crown cementation : a clinical case report", Int J Oral Maxillofac Implants, 23, pp.943~946 (2008)
- Rajan M, "Fabrication of a cement-and screw-retained implant prosthesis", J Prosthet Dent, 92, pp.578~580 (2004)
- Heo YK, "A newly designed screw-and cement-retained prosthesis and its abutments", Int J Prosthodont, 28, pp.612~614 (2015)
- Andersson M, "Accuracy of machine milling and spark erosion with a CAD", CAM system, 1996, pp.76, 187~193
- Priest G, "Virtual-designed and computer-milled implant abutments", J Oral Maxillofac Surg, 63, pp.22~32 (2005)
- Jemt T, "A comparison of laser-welded titanium and conventional cast frameworks supported by implants in the partially edentulous jaw : a 3-year prospective multicenter study", Int J Prosthodont, 13, pp.282~288 (2000)
- Kappel S, "Undetected residual cement on standard or individualized all-ceramic abutments with cemented zirconia single crowns-a prospective randomized pilot trial", Clin Oral Implants Res, 27, pp.1065~1071 (2016)
- Linkevicius T, "The influence of margin location on the amount of undetected cement excess after delivery of cement-retained implant restorations", Clin Oral Implants Res, 22, pp.1379~1384 (2011)
- Kong L, "Selections of the cylinder implant neck taper and implant end fillet for optimal biomechanical properties : a three-dimensional finite element analysis", J Biomech, 41, pp.1124~1130 (2008)
- Tarica DY, "Survey of United States dental schools on cementation protocols for implant crown restorations", J Prosthet Dent, 103, pp.68~79 (2010)
- Aung SSMP, "Effects of alumina-blasting pressure on the bonding to super", ultra-translucent zirconia, 2019, pp.35, 730~739
- Coelho PG, "Fatigue testing of two porcelain-zirconia all-ceramic crown systems", Dent Mater, 25, pp.1122~1127 (2009)
- Linkevicius T, "The influence of the cementation margin position on the amount of undetected cement. A prospective clinical study", Clin Oral Implants Res, 24, pp.71~76 (2013)
- Berglundh T, "Dimension of the periimplant mucosa. Biological width revisited", J Clin Periodontol, 23, pp.971~973 (1996)
- Berglundh T, "The soft tissue barrier at implants and teeth", Clin Oral Implants Res, 2, pp.81~90 (1991)
- Berglundh T, "The topography of the vascular systems in the periodontal and peri-implant tissues in the dog", J Clin Periodontol, 21, pp.189~193 (1994)
- Vindasiute E, "Clinical factors influencing removal of the cement excess in implant-supported restorations", Clin Implant Dent Relat Res, 17, pp.771~778 (2015)
- 김미주, "임플란트 지지 나사-시멘트 유지형 보철물에서 보철물-지대주 제거 후 변연부 연마의 효과: 증례보고", 대한치과보철학회지, 58(3), pp.239~243 (2020), 대한치과보철학회[DOI]
- Lee JH, "Influence of Luting materials and methods and the restoration surface on the amount of cement remnants in implant restorations", J Oral Implantol, 45, pp.301~307 (2019)
- Galván G, "Cemented implant restoration : A technique for minimizing adverse biologic consequences", J Prosthet Dent, 114, pp.482~485 (2015)
- Wadhwani C, "Technique for controlling the cement for an implant crown", J Prosthet Dent, 102, pp.57~58 (2009)
- Hess TA, "A technique to eliminate subgingival cement adhesion to implant abutments by using polytetrafluoroethylene tape", J Prosthet Dent, 112, pp.365~368 (2014)
- Seo CW, "A technique for minimizing subgingival residual cement by using rubber dam for cement-retained implant crowns", J Prosthet Dent, 117, pp.327~328 (2017)
- Korsch M, "Predictors of excess cement and tissue response to fixed implant-supported dentures after cementation", Clin Implant Dent Relat Res, 17, pp.e45~e53 (2015)
