본문 바로가기
KERD
논문KCI 등재

Influence of abutment height and convergence angle on the retrievability of cement-retained implant prostheses with a lingual slot

2

조회

0

다운로드

0

인용

0

참고문헌

키워드

초록

PURPOSE. Cement-retained implant prostheses can lack proper retrievability during repair, and residual cement can cause peri-implantitis. The purpose of this in vitro study was to evaluate the influence of abutment height and convergence angle on the retrievability of cement-retained implant prostheses with lingual slots, known as retrievable cement-type slots (RCS). MATERIALS AND METHODS. We fabricated six types of titanium abutments (10 of each type) with two different heights (4 mm and 6 mm), three different convergence angles (8°, 10°, and 12°), a sloped shoulder margin (0.6 mm depth), a rectangular shape (6 mm × 6.5 mm) with rounded edges, and a rectangular ledge (2 mm × 1 mm) for the RCS. One monolithic zirconia crown was fabricated for each abutment using a dental computer-aided design/computer-aided manufacturing system. The abutments and crowns were permanently cemented together with dual-curing resin cement, followed by 24 hours in demineralized water at room temperature. Using a custom-made device with a slot driver and torque gauge, we recorded the torque (N·cm) required to remove the crowns. Statistical analysis was conducted using multiple regression analysis and Mann-Whitney U tests (α=.05). RESULTS. Removal torques significantly decreased as convergence angles increased. Multiple regression analysis showed no significant interaction between the abutment height and the convergence angle (Durbin-Watson ratio: 2.186). CONCLUSION. Within the limitations of this in vitro study, we suggest that the retrievability of cement-retained implant prostheses with RCS can be maintained by adjusting the abutment height and convergence angle, even when they are permanently cemented together.

Abstract

PURPOSE. Cement-retained implant prostheses can lack proper retrievability during repair, and residual cement can cause peri-implantitis. The purpose of this in vitro study was to evaluate the influence of abutment height and convergence angle on the retrievability of cement-retained implant prostheses with lingual slots, known as retrievable cement-type slots (RCS). MATERIALS AND METHODS. We fabricated six types of titanium abutments (10 of each type) with two different heights (4 mm and 6 mm), three different convergence angles (8°, 10°, and 12°), a sloped shoulder margin (0.6 mm depth), a rectangular shape (6 mm × 6.5 mm) with rounded edges, and a rectangular ledge (2 mm × 1 mm) for the RCS. One monolithic zirconia crown was fabricated for each abutment using a dental computer-aided design/computer-aided manufacturing system. The abutments and crowns were permanently cemented together with dual-curing resin cement, followed by 24 hours in demineralized water at room temperature. Using a custom-made device with a slot driver and torque gauge, we recorded the torque (N·cm) required to remove the crowns. Statistical analysis was conducted using multiple regression analysis and Mann-Whitney U tests (α=.05). RESULTS. Removal torques significantly decreased as convergence angles increased. Multiple regression analysis showed no significant interaction between the abutment height and the convergence angle (Durbin-Watson ratio: 2.186). CONCLUSION. Within the limitations of this in vitro study, we suggest that the retrievability of cement-retained implant prostheses with RCS can be maintained by adjusting the abutment height and convergence angle, even when they are permanently cemented together.

참고문헌 (32)

  1. Misch CE, "Contemporary implant dentistry", pp.549~593 (1999), Mosby Inc
  2. Misch CE, "Screw-retained versus cement-retained implant supported prostheses", Pract Periodontics Aesthet Dent, 7, pp.15~18 (1995)
  3. Hebel KS, "Cement-retained versus screw-retained implant restorations: achieving optimal occlusion and esthetics in implant dentistry", J Prosthet Dent, 77, pp.28~35 (1997)[DOI]
  4. Chee W, "Cemented versus screw-retained implant prostheses: which is better?", Int J Oral Maxillofac Implants, 14, pp.137~141 (1999)
  5. Ekfeldt A, "Clinical evaluation of single-tooth restorations supported by osseointegrated implants: a retrospective study", Int J Oral Maxillofac Implants, 9, pp.179~183 (1994)
  6. Breeding LC, "Use of luting agents with an implant system: Part I", J Prosthet Dent, 68, pp.737~741 (1992)[DOI]
  7. Valbao FP Jr, "Alternative method for retention and removal of cement-retained implant prostheses", J Prosthet Dent, 86, pp.181~183 (2001)[DOI]
  8. Clausen GF, "The lingual locking screw for implant-retained restorations--aesthetics and retrievability", Aust Prosthodont J, 9, pp.17~20 (1995)
  9. Doerr J, "Simplified technique for retrieving cemented implant restorations", J Prosthet Dent, 88, pp.352~353 (2002)[DOI]
  10. Daher T, "The use of digital photographs to locate implant abutment screws for implant-supported cement-retained restorations", J Prosthet Dent, 100, pp.238~239 (2008)[DOI]
  11. Wadhwani C, "Simple device for locating the abut- ment screw position of a cement-retained implant restoration", J Prosthet Dent, 109, pp.272~274 (2013)[DOI]
  12. Prestipino V, "A practical approach for retrieving cement-retained, implant-supported restorations", Quintessence Dent Technol, 24, pp.182~187 (2001)
  13. Schweitzer DM, "A technique for retrieval of cement-retained implant-supported prostheses", J Prosthet Dent, 106, pp.134~138 (2011)[DOI]
  14. Shareen H Elshiyab, "Fracture resistance of implantsupported monolithic crowns cemented to zirconia hybridabutments: zirconia-based crowns vs. lithium disilicate crowns", The Journal of Advanced of Prosthodontics, 10(1), pp.65~72 (2018), 대한치과보철학회[DOI]
  15. Matthias Rödiger, "Evaluation of removal forces of implant-supported zirconia copings depending on abutment geometry, luting agent and cleaning method during re-cementation", The Journal of Advanced of Prosthodontics, 6(3), pp.233~240 (2014), 대한치과보철학회[DOI]
  16. Mehl C, "Influence of abutment height and thermocycling on retrievability of cemented implant-supported crowns", Int J Oral Maxillofac Implants, 27, pp.1106~1115 (2012)
  17. Mehl C, "In vitro influence of ultrasonic stress, removal force preload and thermocycling on the retrievability of implant-retained crowns", Clin Oral Implants Res, 23, pp.930~937 (2012)[DOI]
  18. Pintinha M, "Effect of mechanical loading on the removal torque of different types of tapered connection abutments for dental implants", J Prosthet Dent, 110, pp.383~388 (2013)[DOI]
  19. Mehl C, "Influence of cement film thickness on the retention of implant-retained crowns", J Prosthodont, 22, pp.618~625 (2013)[DOI]
  20. Abbo B, "Resistance to dis- lodgement of zirconia copings cemented onto titanium abut- ments of different heights", J Prosthet Dent, 99, pp.25~29 (2008)[DOI]
  21. Sina Safari, "Effects of abutment diameter, luting agent type, and re-cementation on the retention of implant-supported CAD", CAM metal copings over short abutments, 2018, pp.10(1), 1~7[DOI]
  22. Covey DA, "Effects of abutment size and luting cement type on the uniaxial retention force of implant-supported crowns", J Prosthet Dent, 83, pp.344~348 (2000)[DOI]
  23. Bresciano M, "Retention of luting agents on implant abutments of different height and taper", Clin Oral Implants Res, 16, pp.594~598 (2005)[DOI]
  24. Mehl C, "Retrievability of implant-retained crowns following cementation", Clin Oral Implants Res, 19, pp.1304~1311 (2008)[DOI]
  25. Heinemann F, "Retrospective evaluation of temporary cemented, tooth and implant supported fixed partial dentures", J Craniomaxillofac Surg, 34, pp.86~90 (2006)
  26. Lim HP, "Fracture load of implant-supported zirconia all-ceramic crowns luted with various cements", Int J Prosthodont, 23, pp.361~363 (2010)
  27. Arrais CA, "Microtensile bond strength of dual-polymerizing cementing systems to dentin using different polymerizing modes", J Prosthet Dent, 97, pp.99~106 (2007)[DOI]
  28. Luhrs AK, "Composite cements benefit from light-curing", Dent Mater, 30, pp.292~301 (2014)[DOI]
  29. 염승현, "Effect of dentin pretreatment and curing mode on the microtensile bond strength of self-adhesive resin cements", The Journal of Advanced of Prosthodontics, 7(4), pp.317~322 (2015), 대한치과보철학회[DOI]
  30. Pan YH, "The effect of luting agents on the retention of dental implant-supported crowns", Chang Gung Med J, 28, pp.403~410 (2005)
  31. Harder S, "Molecular leakage at implant-abutment connection--in vitro investigation of tightness of internal conical implant-abutment connections against endotoxin penetration", Clin Oral Investig, 14, pp.427~432 (2010)[DOI]
  32. Chaar MS, "Prosthetic outcome of cementretained implant-supported fixed dental restorations: a systematic review", J Oral Rehabil, 38, pp.697~711 (2011)[DOI]

관련 논문AI추천

Effect of abutment neck taper and cement types on the amount of remnant cement in cement-retained implant restorations: an in vitro study권태민, 김경아, 박연희, 서재민, 이정진대한치과보철학회 · The Journal of Advanced of Prosthodontics2022 · 제14권 제3호Effect of cement washout on loosening of abutment screws and vice versa in screw- and cement- retained implant-supported dental prosthesis김석규, 손미경, 정재헌대한치과보철학회 · The Journal of Advanced of Prosthodontics2015 · 제7권 제3호Effects of abutment diameter, luting agent type, and re-cementation on the retention of implant-supported CAD/CAM metal copings over short abutmentsFereshteh Hosseini Ghavam, Kaveh Yaghmaei, Parviz Amini, Sina Safari대한치과보철학회 · The Journal of Advanced of Prosthodontics2018 · 제10권 제1호Evaluation of removal forces of implant-supported zirconia copings depending on abutment geometry, luting agent and cleaning method during re-cementationFenja Ehret-Kleinau, Franziska Pohlmeyer, Katharina Lange, Matthias Rödiger, Nikolaus Gersdorff, Ralf Bürgers, Sven Rinke대한치과보철학회 · The Journal of Advanced of Prosthodontics2014 · 제6권 제3호Influence of misfit direction and abutment type on torque loss and fracture strength of implant-supported fixed dental prosthesesDaniel Kules, Ieva Gendviliene, Ingrida Mischitz, Liudas Auškalnis, Maisa Haiek, Mutlu Özcan, Tan Fırat Eyüboğlu, Vygandas Rutkūnas대한치과보철학회 · The Journal of Advanced of Prosthodontics2025 · 제17권 제6호Effect of Indented Structures on the Retention of Cement-Retained Implant-Supported Crowns by Provisional Cement곽재영, 김성균, 박지만, 안진수, 최정훈, 허성주대한구강악안면임플란트학회 · 대한구강악안면임플란트학회지2022 · 제26권 제2호

이 간행물의 다른 논문 (8건)