Effect of post-rinsing time and method on accuracy of denture base manufactured with stereolithography
1
조회
0
다운로드
1
인용
0
참고문헌
키워드
초록
PURPOSE. This in vitro study investigates the effect of different post-rinsing times and methods on the trueness and precision of denture base resin manufactured through stereolithography. MATERIALS AND METHODS. Ninety clear photopolymer resin specimens were fabricated and divided into nine groups (n = 10) based on rinsing times and methods. All specimens were rinsed with 99% isopropanol alcohol for 5, 10, and 15 min using three methods-automated, ultrasonic cleaning, and hand washing. The specimens were polymerized for 30 min at 40°C. For trueness, the scanned intaglio surface of each SLA denture base was superimposed on the original standard tessellation language (STL) file using best-fit alignment (n = 10). For precision, the scanned intaglio surface of the STL file in each specimen group was superimposed across each specimen (n = 45). The root mean square error (RMSE) was measured, and the data were analyzed statistically through one-way ANOVA and Tukey test (α < .05). RESULTS. The 10-min automated group exhibited the lowest RMSE. For trueness, this was significantly different from specimens in the 5-min hand-washed group (P < .05). For precision, this was significantly different from those of other groups (P < .05), except for the 15-min automated and 15-min ultrasonic groups. The color map results indicated that the 10-min automated method exhibited the most uniform distribution of the intaglio surface adaptation. CONCLUSION. The optimal postprocessing rinsing times and methods for achieving clear photopolymer resin were found to be the automated method with rinsing times of 10 and 15 min, and the ultrasonic method with a rinsing time of 15 min.
Abstract
PURPOSE. This in vitro study investigates the effect of different post-rinsing times and methods on the trueness and precision of denture base resin manufactured through stereolithography. MATERIALS AND METHODS. Ninety clear photopolymer resin specimens were fabricated and divided into nine groups (n = 10) based on rinsing times and methods. All specimens were rinsed with 99% isopropanol alcohol for 5, 10, and 15 min using three methods-automated, ultrasonic cleaning, and hand washing. The specimens were polymerized for 30 min at 40°C. For trueness, the scanned intaglio surface of each SLA denture base was superimposed on the original standard tessellation language (STL) file using best-fit alignment (n = 10). For precision, the scanned intaglio surface of the STL file in each specimen group was superimposed across each specimen (n = 45). The root mean square error (RMSE) was measured, and the data were analyzed statistically through one-way ANOVA and Tukey test (α < .05). RESULTS. The 10-min automated group exhibited the lowest RMSE. For trueness, this was significantly different from specimens in the 5-min hand-washed group (P < .05). For precision, this was significantly different from those of other groups (P < .05), except for the 15-min automated and 15-min ultrasonic groups. The color map results indicated that the 10-min automated method exhibited the most uniform distribution of the intaglio surface adaptation. CONCLUSION. The optimal postprocessing rinsing times and methods for achieving clear photopolymer resin were found to be the automated method with rinsing times of 10 and 15 min, and the ultrasonic method with a rinsing time of 15 min.
참고문헌 (38)
- Park ME, "Three-dimensional comparative study on the accuracy and reproducibility of dental casts fabricated by 3D printers", J Prosthet Dent, 119, pp.861~ (2018)
- Steinmassl O, "CAD", CAM produces dentures with improved fit, 2018, pp.22, 2829~2835
- Inokoshi M, "Evaluation of a complete denture trial method applying rapid prototyping", Dent Mater J, 31, pp.40~46 (2012)
- Kanazawa M, "Trial of a CAD", CAM system for fabricating complete dentures, 2011, pp.30, 93~96
- Strub JR, "Computer-aided design and fabrication of dental restorations : current systems and future possibilities", J Am Dent Assoc, 137, pp.1289~1296 (2006)
- Torabi K, "Rapid prototyping technologies and their applications in prosthodontics:a review of literature", J Dent(Shiraz), 16, pp.1~9 (2015)
- 강신영, "Accuracy of provisional crowns made using stereolithography apparatus and subtractive technique", The Journal of Advanced of Prosthodontics, 10(5), pp.354~360 (2018), 대한치과보철학회[DOI]
- Park JY, "In vitro assessment of the marginal and internal fits of interim implant restorations fabricated with different methods", J Prosthet Dent, 116, pp.536~542 (2016)
- Wang C, "Accuracy of digital complete dentures : a systematic review of in vitro studies", J Prosthet Dent, 125, pp.249~256 (2021)
- van Noort R, "The future of dental devices is digital", Dent Mater, 28, pp.3~12 (2012)
- Janeva NM, "Advantages of CAD", CAM versus conventional complete dentures : a review, 2018, pp.6, 1498~1502
- Kalberer N, "CAD-CAM milled versus rapidly prototyped(3D-printed)complete dentures : an in vitro evaluation of trueness", J Prosthet Dent, 121, pp.637~643 (2019)
- Azari A, "The evolution of rapid prototyping in dentistry : a review", Rapid Prototyping J, 15, pp.216~225 (2009)
- Nestler N, "Dimensional accuracy of extrusion-and photopolymerization-based 3D printers : in vitro study comparing printed casts", J Prosthet Dent, 125, pp.103~110 (2021)
- Piedra-Cascón W, "3D printing parameters, supporting structures, slicing, and post-processing procedures of vat-polymerization additive manufacturing technologies:A narrative review", J Dent, 109, pp.103630~ (2021)
- Alharbi N, "Factors influencing the dimensional accuracy of 3D-printed full-coverage dental restorations using stereolithography technology", Int J Prosthodont, 29, pp.503~510 (2016)
- Hada T, "Effect of printing direction on the accuracy of 3D-printed dentures using stereolithography technology", Materials(Basel), 13, pp.3405~ (2020)
- Karakurt I, "3D printing technologies: techniques, materials, and post-processing", Curr Opin Chem Eng, 28, pp.134~143 (2020)
- Kim D, "Effects of post-curing time on the mechanical and color properties of three-dimensional printed crown and bridge materials", Polymers, 12, pp.2762~ (2020)
- "ISO 5725-1. Accuracy (trueness and precision) of measurement methods and results. Part 1: general principles and definitions" (1994)[URL]
- Hwang HJ, "Assessment of the trueness and tissue surface adaptation of CADCAM maxillary denture bases manufactured using digital light processing", J Prosthet Dent, 121, pp.110~117 (2019)
- Goodacre BJ, "Comparison of denture base adaptation between CAD-CAM and conventional fabrication techniques", J Prosthet Dent, 116, pp.249~256 (2016)
- Yoon HI, "Evaluation of the trueness and tissue surface adaptation of CAD-CAM mandibular denture bases manufactured using digital light processing", J Prosthet Dent, 120, pp.919~926 (2018)
- Katheng A, "Evaluation of trueness and precision of stereolithography-fabricated photopolymer-resin dentures under different postpolymerization conditions : an in vitro study", J Prosthet Dent (2021)
- Ammoun R, "Effects of two postprocessing methods onto surface dimension of in-office fabricated stereolithographic implant surgical guides", J Prosthodont, 30, pp.71~75 (2021)
- Mostafavi D, "Influence of the rinsing postprocessing procedures on the manufacturing accuracy of vat-polymerized dental model material", J Prosthodont, 30, pp.610~616 (2021)
- 이범일, "Effect of rinsing time on the accuracy of interim crowns fabricated by digital light processing: An in vitro study", The Journal of Advanced of Prosthodontics, 13(1), pp.24~35 (2021), 대한치과보철학회[DOI]
- Xu Y, "Effect of post-rinsing time on the mechanical strength and cytotoxicity of a 3D printed orthodontic splint material", Dent Mater, 37, pp.e314~e327 (2021)
- Mayer J, "Influence of cleaning methods after 3D printing on two-body wear and fracture load of resin-based temporary crown and bridge material", Clin Oral Investig, 25, pp.5987~5996 (2021)
- Al-Imam H, "Accuracy of stereolithography additive casts used in a digital workflow", J Prosthet Dent, 119, pp.580~585 (2018)
- Artopoulos A, "Three-dimensional processing deformation of three denture base materials", J Prosthet Dent, 110, pp.481~487 (2013)
- Kim SY, "Precision and trueness of dental models manufactured with different 3-dimensional printing techniques", Am J Orthod Dentofacial Orthop, 153, pp.144~153 (2018)
- Cho SH, "Comparison of accuracy and reproducibility of casts made by digital and conventional methods", J Prosthet Dent, 113, pp.310~315 (2015)
- Osman RB, "Build angle : does it influence the accuracy of 3D-printed dental restorations using digital light-processing technology?", Int J Prosthodont, 30, pp.182~188 (2017)
- Alharbi N, "Effects of build direction on the mechanical properties of 3D-printed complete coverage interim dental restorations", J Prosthet Dent, 115, pp.760~767 (2016)
- Katheng A, "Evaluation of dimensional accuracy and degree of polymerization of stereolithography photopolymer resin under different postpolymerization conditions : an in vitro study", J Prosthet Dent, 125, pp.695~702 (2021)
- Papanu J, "Swelling of poly(methyl methacrylate)thin films in low molecular weight alcohols", J Appl Polym Sci, 39, pp.803~823 (1990)
- Alshali RZ, "Post-irradiation hardness development, chemical softening, and thermal stability of bulk-fill and conventional resin-composites", J Dent, 43, pp.209~218 (2015)