Effect of internal structures on the accuracy of 3D printed full-arch dentition preparation models in different printing systems
2
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
PURPOSE. The objective of this study was to investigate how internal structures influence the overall and marginal accuracy of full arch preparations fabricated through additive manufacturing in different printing systems. MATERIALS AND METHODS. A full-arch preparation digital model was set up with three internal designs, including solid, hollow, and grid. These were printed using three different resin printers with nine models in each group. After scanning, each data was imported into the 3D data processing software together with the master cast, aligned and trimmed, and then put into the 3D data analysis software again to compare the overall and marginal deviation whose results are expressed using root mean square values and color maps. To evaluate the trueness of the resin model, the test data and reference data were compared, and the precision was evaluated by comparing the test data sets. Color maps were observed for qualitative analysis. Data were statistically analyzed by one-way analysis of variance and Bonferroni method was used for post hoc comparison (α = .05). RESULTS. The influence of different internal structures on the accuracy of 3D printed resin models varied significantly (P < .05). Solid and grid models showed better accuracy, while the hollow model exhibited poor accuracy. The color maps show that the resin models have a tendency to shrink inwards. CONCLUSION. The internal structure design influences the accuracy of the 3D printing model, and the effect varies in different printing systems. Irrespective of the kind of printing system, the printing accuracy of hollow model was observed to be worse than those of solid and grid models.
Abstract
PURPOSE. The objective of this study was to investigate how internal structures influence the overall and marginal accuracy of full arch preparations fabricated through additive manufacturing in different printing systems. MATERIALS AND METHODS. A full-arch preparation digital model was set up with three internal designs, including solid, hollow, and grid. These were printed using three different resin printers with nine models in each group. After scanning, each data was imported into the 3D data processing software together with the master cast, aligned and trimmed, and then put into the 3D data analysis software again to compare the overall and marginal deviation whose results are expressed using root mean square values and color maps. To evaluate the trueness of the resin model, the test data and reference data were compared, and the precision was evaluated by comparing the test data sets. Color maps were observed for qualitative analysis. Data were statistically analyzed by one-way analysis of variance and Bonferroni method was used for post hoc comparison (α = .05). RESULTS. The influence of different internal structures on the accuracy of 3D printed resin models varied significantly (P < .05). Solid and grid models showed better accuracy, while the hollow model exhibited poor accuracy. The color maps show that the resin models have a tendency to shrink inwards. CONCLUSION. The internal structure design influences the accuracy of the 3D printing model, and the effect varies in different printing systems. Irrespective of the kind of printing system, the printing accuracy of hollow model was observed to be worse than those of solid and grid models.
참고문헌 (32)
- Schweiger J, "3D printing in digital prosthetic dentistry : An overview of recent developments in additive manufacturing", J Clin Med, 10, pp.2010~ (2021)
- Revilla-León M, "Additive manufacturing technologies used for processing polymers : current status and potential application in prosthetic dentistry", J Prosthodont, 28, pp.146~158 (2019)
- Khorsandi D, "3D and 4D printing in dentistry and maxillofacial surgery: Printing techniques, materials, and applications", Acta Biomater, 122, pp.26~49 (2021)
- Etemad-Shahidi Y, "Accuracy of 3-dimensionally printed full-arch dental models : a systematic review", J Clin Med, 9, pp.3357~ (2020)
- Czajkowska M, "Comparison of dental stone models and their 3D printed acrylic replicas for the accuracy and mechanical properties", Materials(Basel), 13, pp.4066~ (2020)
- Cicciù M, "3D digital impression systems compared with traditional techniques in dentistry : a recent data systematic review", Materials(Basel), 13, pp.1982~ (2020)
- Gao H, "Accuracy of three digital scanning methods for complete-arch tooth preparation : An in vitro comparison", J Prosthet Dent, 128, pp.1001~1008 (2022)
- 김민규, "Effect of the volumetric dimensions of a complete arch on the accuracy of scanners", The Journal of Advanced of Prosthodontics, 12(6), pp.361~368 (2020), 대한치과보철학회[DOI]
- Son K, "Feasibility of using an intraoral scanner for a complete arch digital scan, part 2: A comparison of scan strategies", J Prosthet Dent, 129, pp.341~349 (2023)
- Baghani MT, "In vitro evaluation of the accuracy and precision of intraoral and extraoral complete-arch scans", J Prosthet Dent, 126, pp.665~670 (2021)
- Anadioti E, "Accuracy of dental and industrial 3D printers", J Prosthodont, 31, pp.30~37 (2022)
- Oberoi G, "3D printing-encompassing the facets of dentistry", Front Bioeng Biotechnol, 6, pp.172~ (2018)
- 정유금, "Accuracy evaluation of dental models manufactured by CAD", CAM milling method and 3D printing method, 2018, pp.10(3), 245~251[DOI]
- Banjar A, "Accuracy of 3D printed implant casts versus stone casts : a comparative study in the anterior maxilla", J Prosthodont, 30, pp.783~788 (2021)
- Ko J, "Effect of build angle and layer height on the accuracy of 3-dimensional printed dental models", Am J Orthod Dentofacial Orthop, 160, pp.451~8.e2 (2021)
- Dong T, "Accuracy of different tooth surfaces on 3D printed dental models : orthodontic perspective", BMC Oral Health, 20, pp.340~ (2020)
- Joda T, "Impact of aging on the accuracy of 3D-printed dental models : an in vitro investigation", J Clin Med, 9, pp.1436~ (2020)
- Rungrojwittayakul O, "Accuracy of 3D printed models created by two technologies of printers with different designs of model base", J Prosthodont, 29, pp.124~128 (2020)
- Kim SY, "Precision and trueness of dental models manufactured with different 3-dimensional printing techniques", Am J Orthod Dentofacial Orthop, 153, pp.144~153 (2018)
- Shin SH, "Evaluation of the 3D printing accuracy of a dental model according to its internal structure and crossarch plate design : an in vitro study", Materials(Basel), 13, pp.5433~ (2020)
- Faruqi S, "Digital assessment of marginal accuracy in ceramic crowns fabricated with different marginal finish line configurations", J Esthet Restor Dent, 34, pp.789~795 (2022)
- Baig MR, "Effect of finish line design on the fit accuracy of CAD", CAM monolithic polymer-infiltrated ceramic-network fixed dental prostheses : an in vitro study, 2021, pp.13, 4311~
- Dias Resende CC, "Cost and effectiveness of 3-dimensionally printed model using three different printing layer parameters and two resins", J Prosthet Dent, 129, pp.350~353 (2023)
- Hilin Tas, "Evaluation of the accuracy of dental casts manufactured with 3D printing technique in the All-on-4 treatment concept", The Journal of Advanced of Prosthodontics, 14(6), pp.379~387 (2022), 대한치과보철학회[DOI]
- Reis BS, "Precision and accuracy of four current 3D Printers to achieve models for Fixed Dental Prosthesis", Acta Odontol Latinoam, 33, pp.3~5 (2020)
- Cho SH, "Comparison of accuracy and reproducibility of casts made by digital and conventional methods", J Prosthet Dent, 113, pp.310~315 (2015)
- Kasparova M, "Possibility of reconstruction of dental plaster cast from 3D digital study models", Biomed Eng Online, 12, pp.49~ (2013)
- Park JM, "Dimensional accuracy and surface characteristics of 3D-printed dental casts", J Prosthet Dent, 126, pp.427~437 (2021)
- Park ME, "Three-dimensional comparative study on the accuracy and reproducibility of dental casts fabricated by 3D printers", J Prosthet Dent, 119, pp.861.e1~7 (2018)
- Muallah J, "Accuracy of full-arch scans using intraoral and extraoral scanners : an in vitro study using a new method of evaluation", Int J Comput Dent, 20, pp.151~164 (2017)
- Cakmak G, "Comparison of measured deviations in digital implant scans depending on software and operator", J Dent, 122, pp.104154~ (2022)
- Chiu A, "Accuracy of CAD", CAM digital impressions with different intraoral scanner parameters, 2020, pp.20, 1157~
