본문 바로가기
KERD
논문KCI 등재

Fracture strength and marginal gap comparisons of monolayered and multilayered monolithic zirconia crowns with various milling depths

2

조회

0

다운로드

0

인용

0

참고문헌

키워드

초록

Purpose. This study aimed to compare the marginal adaptation and fracture strength of monolayered and multilayered monolithic zirconia crowns fabricated at three distinct milling depths. Materials and methods. Eighty-four epoxy resin dies of prepared premolars were fabricated. Crowns were designed in software and milled from two monolayered zirconia materials [3Y-TZP (VITA YZ HT)(3-VYZ) and 4Y-TZP (Priti®multidisc ZrO2 Extra Translucent)(4-ET)], three multilayered zirconia materials [3/5Y-TZP (IPS e.max ZirCAD Prime)(3/5-ZP), 4/5Y-TZP (IPS e.max ZirCAD Prime Esthetic)(4/5-ZPE), and 4/5Y-TZP (Priti®multidisc ZrO2 Multi Translucent Plus)(4/5-MTP)], at three milling depths [above (A), center (C), below (B)], and a zirconia-reinforced lithium silicate glass ceramic block (VITA Suprinity)(VS) (n = 7). After sintering and glazing, marginal gaps (MG) were measured using silicone replica technique. Crowns were cemented with dual-cure resin (SpeedCEM Plus, Ivoclar Vivadent), subjected to 5000 thermal cycles. Fracture strength (FS) test was performed perpendicularly to occlusal surface at 1 mm/min. Data were analyzed (SPSS 26, one-way ANOVA, Tukey post-hoc tests, P = .05), and fracture types were classified. SEM analysis was performed on representative specimens. Results. MG differences among groups were insignificant (P > .05). The highest FS values were observed in 3-VYZ (1587.14 ± 228.26 N), 3/5ZP-B (1537.28 ± 268.81 N), and 4-ET (1364.86 ± 196.98 N) (P < .05). The lowest FS values were found in VS (483.86 ± 47.10 N)(P < .05). B-positioned multilayered crowns exhibited numerically higher FS than A or C positions. Conclusion. Monolayered (3Y-TZP and 4Y-TZP) or multilayered 3/5Y-TZP zirconia milled from below layer may be preferred for posterior region, whereas multilayered 3/5Y-TZP milled from upper layer and all configurations of multilayered 4/5Y-TZP may be more suitable for anterior.

Abstract

Purpose. This study aimed to compare the marginal adaptation and fracture strength of monolayered and multilayered monolithic zirconia crowns fabricated at three distinct milling depths. Materials and methods. Eighty-four epoxy resin dies of prepared premolars were fabricated. Crowns were designed in software and milled from two monolayered zirconia materials [3Y-TZP (VITA YZ HT)(3-VYZ) and 4Y-TZP (Priti®multidisc ZrO2 Extra Translucent)(4-ET)], three multilayered zirconia materials [3/5Y-TZP (IPS e.max ZirCAD Prime)(3/5-ZP), 4/5Y-TZP (IPS e.max ZirCAD Prime Esthetic)(4/5-ZPE), and 4/5Y-TZP (Priti®multidisc ZrO2 Multi Translucent Plus)(4/5-MTP)], at three milling depths [above (A), center (C), below (B)], and a zirconia-reinforced lithium silicate glass ceramic block (VITA Suprinity)(VS) (n = 7). After sintering and glazing, marginal gaps (MG) were measured using silicone replica technique. Crowns were cemented with dual-cure resin (SpeedCEM Plus, Ivoclar Vivadent), subjected to 5000 thermal cycles. Fracture strength (FS) test was performed perpendicularly to occlusal surface at 1 mm/min. Data were analyzed (SPSS 26, one-way ANOVA, Tukey post-hoc tests, P = .05), and fracture types were classified. SEM analysis was performed on representative specimens. Results. MG differences among groups were insignificant (P > .05). The highest FS values were observed in 3-VYZ (1587.14 ± 228.26 N), 3/5ZP-B (1537.28 ± 268.81 N), and 4-ET (1364.86 ± 196.98 N) (P < .05). The lowest FS values were found in VS (483.86 ± 47.10 N)(P < .05). B-positioned multilayered crowns exhibited numerically higher FS than A or C positions. Conclusion. Monolayered (3Y-TZP and 4Y-TZP) or multilayered 3/5Y-TZP zirconia milled from below layer may be preferred for posterior region, whereas multilayered 3/5Y-TZP milled from upper layer and all configurations of multilayered 4/5Y-TZP may be more suitable for anterior.

관련 논문AI추천

Fracture resistance and marginal fit of the zirconia crowns with varied occlusal thicknessYadel Hazır Tekin, Yeliz Hayran대한치과보철학회 · The Journal of Advanced of Prosthodontics2020 · 제12권 제5호Effect of position within a blank and thermo-mechanical aging on fracture force and failure mode of strength-gradient multilayer zirconia crownsOnauma Angwaravong, Surangkana Imaemporn, Thidarat Angwarawong대한치과보철학회 · The Journal of Advanced of Prosthodontics2025 · 제17권 제6호Influence of preparation design on fracture resistance of different monolithic zirconia crowns: A comparative studyHaider Hasan Jasim, Meelad Basil Findakly대한치과보철학회 · The Journal of Advanced of Prosthodontics2019 · 제11권 제6호In vitro evaluation of fracture strength of zirconia restoration veneered with various ceramic materials김성훈, 여인성, 이재봉, 최유성, 한중석대한치과보철학회 · The Journal of Advanced of Prosthodontics2012 · 제4권 제3호Monolithic zirconia crowns: effect of thickness reduction on fatigue behavior and failure loadEstevam Augusto Bonfante, Frank Akito Spitznagel, Lea Sophia Prott, Meike Anne Malassa, Petra Christine Gierthmuehlen대한치과보철학회 · The Journal of Advanced of Prosthodontics2021 · 제13권 제5호Fracture resistance of CAD-CAM all-ceramic surveyed crowns with different occlusal rest seat designsAbdulbari Alqahtani, Ebrahim Alsubaiy, Gotam Das, Saleh Alsolami, Saurabh Chaturvedi, Turki Alqahtani대한치과보철학회 · The Journal of Advanced of Prosthodontics2021 · 제13권 제1호

이 간행물의 다른 논문 (6건)