논문KCI 등재
Effect of Blood Collection Tubes on Vitamin D Immunoassay Results
2
조회
0
다운로드
0
인용
0
참고문헌
주제분류병리학
참고문헌 (7)
- Bowen RAR, "Impact of blood collection devices on clinical chemistry assays", Clin Biochem, 43, pp.4~25 (2010)
- Holick MF, "Evaluation, treatment, and prevention of vitamin D deficiency:an Endocrine Society clinical practice guideline", J Clin Endocrinol Metab, 96, pp.1911~1930 (2011)
- Seo JD, "Evaluation of test standardization of 25-OH vitamin D immunoassays", Lab Med Online, 14, pp.8~16 (2024)
- Bowen RAR, "Immunoassay interference by a commonly used blood collection tube additive, the organosilicone surfactant silwet L-720", Clin Chem, 51, pp.1874~1882 (2005)
- Yu S, "25OHD analogues and vacuum blood collection tubes dramatically affect the accuracy of automated immunoassays", Sci Rep, 5, pp.14636~ (2015)
- Yu S, "Blood collection tubes and storage temperature should be evaluated when using the Siemens ADVIA Centaur XP for measuring 25-hydroxyvitamin D", PLoS One, 11, pp.e0166327~ (2016)
- Kricka LJ, "Processing controls in blood collection tubes reveals interference", Clin Chem, 51, pp.2422~2423 (2005)
관련 논문AI추천
Efficacy of the Measurement of 25-Hydroxyvitamin D2 and D3 Levels by Using PerkinElmer Liquid Chromatography-Tandem Mass Spectrometry Vitamin D Kit Compared With DiaSorin Radioimmunoassay Kit and Elecsys Vitamin D Total Assay곽호석, 구은숙, 박미현, 박은정, 오한진, 정희정, 조동희대한진단검사의학회 · Annals of Laboratory Medicine2015 · 제35권 제2호Evaluation of Test Standardization for 25-OH Vitamin D Immunoassays서종도, 송정한, 윤여민, 이용화, 이준희, 조성은대한진단검사의학회 · Laboratory Medicine Online2024 · 제14권 제1호Discrepancy between Vitamin D Total Immunoassays due to Various Cross-reactivities권오주, 박애자, 이준형, 최지혜대한골대사학회 · 대한골대사학회지2015 · 제22권 제3호Comparison of Three Commercially Available Assays for Measurement of Vitamin D양다해, 황현용대한진단검사의학회 · Laboratory Medicine Online2017 · 제7권 제3호Comparison of Three Blood Collection Tubes for 35 Biochemical Analytes: The Becton Dickinson Barricor Tube, Serum Separating Tube, and Plasma Separating TubeOh Jongwon, Park Hyung-Doo, Shin Sunghwan대한진단검사의학회 · Annals of Laboratory Medicine2021 · 제41권 제1호검사용기 재질과 저장시간에 따른 일반화학 검사의 비교김각현, 신옥현, 이은주대한임상검사과학회 · 대한임상검사과학회지2001 · 제33권 제2호
이 간행물의 다른 논문 (25건)
Why Terminology Standards Matter for Data-driven Artificial Intelligence in HealthcarePark Hyeoun-Aepp. 467-471Customized Quality Assessment of Healthcare DataKim Jong-Yeup, 신지은pp. 472-477Integration of an MC-80 Digital Image Analyzer With an Automated BC-6800Plus Hematology Analyzer Enables Accurate Platelet Counting in Samples With EDTA-Induced PseudothrombocytopeniaSo Min-Kyung, Park Sholhui, Kim Seunghwan, 허정원pp. 478-486Exploring Appropriate Reference Intervals and Clinical Decision Limits for Glucose-6-Phosphate Dehydrogenase Activity in Individuals From Guangzhou, ChinaZhong Suping, Liu Jinlu, Lin Zhiqian, Lin Lijuan, Fang Yanping, Zeng Jing, Su Zhaoying, Li Huibin, Liang Jianfen, Zhu Biqing, Lin Zipei, Huang Yongxin, Yang Xuexi, Jiang Lingxiao, Huang Zhenyi, Li Ziyan, Li Yating, Cao Yunshanpp. 487-496Diagnostic Accuracy of Plasma Renin Concentration and Renin Activity in Predicting Mortality and Kidney Outcomes in Patients With Septic Shock and Hypoperfusion or Hypotension: A Multicenter, Prospective, Observational StudyShin Tae Gun, 정치량, Lim Tae Ho, Chae Bora, Kim Won Young, 강형구, 오재훈, Park Jong Eun, Lee Gun Tak, Ko Byuk Sung, Kim Da Seul, Kim Minha, Hwang Sung Yeon, Jeong Daunpp. 497-506