본문 바로가기
KERD
논문KCI 등재

Factors Influencing Corneal Flap Thickness in Laser In Situ Keratomileusis with a Femtosecond Laser

2

조회

0

다운로드

1

인용

0

참고문헌

키워드

주제분류안과학

초록

Purpose: To evaluate factors responsible for the variability between intended and achieved corneal-flap thickness during femtosecond laser-assisted laser in situ keratomileusis (LASIK). Methods: A prospective, nonrandomized, case study was performed on 35 eyes of 18 consecutive patients who underwent LASIK surgery using the 60 kHz femtosecond laser microkeratome. Eyes were assigned to three different thickness groups, with 110-, 120-, or 130-μm cut depths. Anterior segment optical coherence tomography was used to assess the morphology of 35 LASIK flaps at postoperative one week postoperatively. The flap thickness was assessed at seven measuring points across each flap. Patient age, preoperative spherical equivalent,manual keratometry, preoperative central pachymetry, and regional variability of the cornea were evaluated to determine where they influenced the achieved corneal flap thickness. Results: Cuttings of all flaps were easily performed without any intraoperative complications. Flap-thickness measurements had a mean of 115.21 ± 4.98 μm (intended thickness, 110 μm), 121.90 ± 5.79 μm (intended, 120 μm),and 134.38 ± 5.04 μm (intended, 130 μm), respectively. There was no significant difference between the 110-μm and 120-μm groups when compared with the 130-μm group (one-way analysis of variance test, p > 0.05). Patients’ age, preoperative spherical equivalent, manual keratometry, and preoperative central pachymetry did not affect the achieved flap thickness (Pearson correlations test, p > 0.05). The reproducibility of flap thickness in the central 1.5-mm radius area was more accurate than that in the peripheral 3.0 to 4.0-mm radius area (paired samples t-test, p < 0.05). Conclusions: Femtosecond laser-assisted LASIK is likely to reproduce a reliable thickness of the corneal flap, which is independent of corneal shape factors or refractive status. Future studies should focus on variations in corneal biomechanical factors, which may also play an important role in determining flap thickness.

Abstract

Purpose: To evaluate factors responsible for the variability between intended and achieved corneal-flap thickness during femtosecond laser-assisted laser in situ keratomileusis (LASIK). Methods: A prospective, nonrandomized, case study was performed on 35 eyes of 18 consecutive patients who underwent LASIK surgery using the 60 kHz femtosecond laser microkeratome. Eyes were assigned to three different thickness groups, with 110-, 120-, or 130-μm cut depths. Anterior segment optical coherence tomography was used to assess the morphology of 35 LASIK flaps at postoperative one week postoperatively. The flap thickness was assessed at seven measuring points across each flap. Patient age, preoperative spherical equivalent,manual keratometry, preoperative central pachymetry, and regional variability of the cornea were evaluated to determine where they influenced the achieved corneal flap thickness. Results: Cuttings of all flaps were easily performed without any intraoperative complications. Flap-thickness measurements had a mean of 115.21 ± 4.98 μm (intended thickness, 110 μm), 121.90 ± 5.79 μm (intended, 120 μm),and 134.38 ± 5.04 μm (intended, 130 μm), respectively. There was no significant difference between the 110-μm and 120-μm groups when compared with the 130-μm group (one-way analysis of variance test, p > 0.05). Patients’ age, preoperative spherical equivalent, manual keratometry, and preoperative central pachymetry did not affect the achieved flap thickness (Pearson correlations test, p > 0.05). The reproducibility of flap thickness in the central 1.5-mm radius area was more accurate than that in the peripheral 3.0 to 4.0-mm radius area (paired samples t-test, p < 0.05). Conclusions: Femtosecond laser-assisted LASIK is likely to reproduce a reliable thickness of the corneal flap, which is independent of corneal shape factors or refractive status. Future studies should focus on variations in corneal biomechanical factors, which may also play an important role in determining flap thickness.

참고문헌 (36)

  1. Choudhri SA, "Factors predictive of LASIK flap thickness with the Hansatome zero compression microkeratome", J Refract Surg, 21, pp.253~259 (2005)
  2. Seiler T, "Iatrogenic keratectasia after LASIK in a case of forme fruste keratoconus", J Cataract Refract Surg, 24, pp.1007~1009 (1998)
  3. Seiler T, "Iatrogenic keratectasia after laser in situ keratomileusis", J Refract Surg, 14, pp.312~317 (1998)
  4. Koch DD, "The riddle of iatrogenic keratectasia", J Cataract Refract Surg, 25, pp.453~454 (1999)
  5. Yildirim R, "Reproducibility of corneal flap thickness in laser in situ keratomileusis using the Hansatome microkeratome", J Cataract Refract Surg, 26, pp.1729~1732 (2000)
  6. Giledi O, "Reproducibility of LASIK flap thickness using the Hansatome microkeratome", J Cataract Refract Surg, 30, pp.1031~1037 (2004)
  7. Krueger RR, "Biomechanical effects of femtosecond and microkeratome-based flap creation:prospective contralateral examination of two patients", J Refract Surg, 23, pp.800~807 (2007)
  8. Alió JL, "Very high-frequency digital ultrasound measurement of the LASIK flap thickness profile using the IntraLase femtosecond laser and M2 and Carriazo-Pendular microkeratomes", J Refract Surg, 24, pp.12~23 (2008)
  9. Choi SK, "Creation of an extremely thin flap using IntraLase femtosecond laser", J Cataract Refract Surg, 34, pp.864~867 (2008)
  10. Kohnen T, "Internal anterior chamber diameter using optical coherence tomography compared with white-to-white distances using automated measurements", J Cataract Refract Surg, 32, pp.1809~1813 (2006)
  11. Li Y, "A longitudinal study of LASIK flap and stromal thickness with high-speed optical coherence tomography", Ophthalmology, 114, pp.1124~1132 (2007)
  12. Pallikaris IG, "Laser in situ keratomileusis", Lasers Surg Med, 10, pp.463~468 (1990)
  13. Behrens A, "Experimental evaluation of two current-generation automated microkeratomes:the Hansatome and the Supratome", Am J Ophthalmol, 129, pp.59~67 (2000)
  14. Sarkisian KA, "Experience with the Nidek MK-2000 microkeratome in 1,220 cases", J Refract Surg, 17(2 Suppl)), pp.S252~S254 (2001)
  15. Choi YI, "Corneal flap dimensions in laser in situ keratomileusis using the innovatome automatic microkeratome", Korean J Ophthalmol, 14, pp.7~11 (2000)
  16. Shemesh G, "Predictability of corneal flap thickness in laser in situ keratomileusis using three different microkeratomes", J Refract Surg, 18(3), pp.S347~S351 (2002)
  17. Spadea L, "Flap measurements with the Hansatome microkeratome", J Refract Surg, 18, pp.149~154 (2002)
  18. Arbelaez MC, "Nidek MK 2000 microkeratome clinical evaluation", J Refract Surg, 18(3 Suppl), pp.S357~S360 (2002)
  19. Flanagan GW, "Precision of flap measurements for laser in situ keratomileusis in 4428 eyes", J Refract Surg, 19, pp.113~123 (2003)
  20. Solomon KD, "Flap thickness accuracy:comparison of 6 microkeratome models", J Cataract Refract Surg, 30, pp.964~977 (2004)
  21. Duffey RJ, "Thin flap laser in situ keratomileusis:flap dimensions with the Moria LSK-One manual microkeratome using the 100-microm head", J Cataract Refract Surg, 31, pp.1159~1162 (2005)
  22. Solomon KD, "Flap thickness accuracy:comparison of 6 microkeratome models", J Cataract Refract Surg, 30, pp.964~977 (2004)
  23. Holzer MP, "Corneal flap complications in refractive surgery.Part 1:development of an experimental animal model", J Cataract Refract Surg, 29, pp.795~802 (2003)
  24. Ambrósio R Jr, "Complications of laser in situ keratomileusis:etiology,prevention,and treatment", J Refract Surg, 17, pp.350~379 (2001)
  25. Kurtz RM, "Lamellar refractive surgery with scanned intrastromal picosecond and femtosecond laser pulses in animal eyes", J Refract Surg, 14, pp.541~548 (1998)
  26. Sarayba MA, "Femtosecond laser posterior lamellar keratoplasty:a laboratory model", Cornea, 24, pp.328~333 (2005)
  27. Soong HK, "Femtosecond laserassisted posterior lamellar keratoplasty:initial studies of surgical technique in eye bank eyes", Ophthalmology, 112, pp.44~49 (2005)
  28. Seitz B, "Nonmechanical posterior lamellar keratoplasty using the femtosecond laser(femto-plak)for corneal endothelial decompensation", Am J Ophthalmol, 136, pp.769~772 (2003)
  29. Seitz B, "Inverse mushroom-shaped nonmechanical penetrating keratoplasty using a femtosecond laser", Am J Ophthalmol, 139, pp.941~944 (2005)
  30. Jonas JB, "Femtosecond laser penetrating keratoplasty with conical incisions and positional spikes", J Refract Surg, 20, pp.397~ (2004)
  31. Pfaeffl WA, "Predictive factors of femtosecond laser flap thickness measured by online optical coherence pachymetry subtraction in sub-Bowman keratomileusis", J Cataract Refract Surg, 34, pp.1872~1880 (2008)
  32. Binder PS, "Flap dimensions created with the IntraLase FS laser", J Cataract Refract Surg, 30, pp.26~32 (2004)
  33. Sutton G, "Accuracy and precision of LASIK flap thickness using the IntraLase femtosecond laser in 1000 consecutive cases", J Refract Surg, 24, pp.802~806 (2008)
  34. Li Y, "Corneal pachymetry mapping with high-speed optical coherence tomography", Ophthalmology, 113, pp.792~799.e2 (2006)
  35. von Jagow B, "Corneal architecture of femtosecond laser and microkeratome flaps imaged by anterior segment optical coherence tomography", J Cataract Refract Surg, 35, pp.35~41 (2009)
  36. Dawson DG, "Biomechanical and wound healing characteristics of corneas after excimer laser keratorefractive surgery: is there a difference between advanced surface ablation and sub-Bowman's keratomileusis?", J Refract Surg, 24, pp.S90~S96 (2008)

관련 논문AI추천

Comparison of Laser In Situ Keratomileusis Flap Morphology and Predictability by WaveLight FS200 Femtosecond Laser and Moria Microkeratome: An Anterior Segment Optical Coherence Tomography StudyMahmoud A. Abdelsalam, Mohamed A. Nassr, Mohamed S. Hussein, Zeiad H. Eldaly대한안과학회 · Korean Journal of Ophthalmology2019 · 제33권 제2호The Impact of Learning Curve on Flap Thickness Outcome in Femtosecond Laser-assisted Laser In Situ Keratomileusis Performed with New LenSx Dual PlatformAshish Ahuja, Bilgehan Sezgin Asena대한안과학회 · Korean Journal of Ophthalmology2022 · 제36권 제3호Factors Affecting Long-term Myopic Regression after Laser In Situ Keratomileusis and Laser-assisted Subepithelial Keratectomy for Moderate Myopia나경선, 주천기, Sung A Lim, Yooyeon Park, Yu Jin Cheong대한안과학회 · Korean Journal of Ophthalmology2016 · 제30권 제2호Lower Energy to Make a Corneal Flap with a 60 kHz Femtosecond Laser Reduces Flap Inflammation and Corneal Stromal Cell Death But Weakens Flap Adhesion김명준, 김재용, 주성우, 차흥원, 선우정혜대한안과학회 · Korean Journal of Ophthalmology2013 · 제27권 제2호각막절편 두께 측정법의 비교: 초음파 각막두께측정계의 차감법, 직접측정법과 빛간섭단층촬영계김명준, 김재용, 이수환, 이주은, 차흥원대한안과학회 · 대한안과학회지2011 · 제52권 제5호Higher Order Aberrations of the Corneal Surface after Laser Subepithelial Keratomileusis오한진, 윤경철, 정현호, 지영석대한안과학회 · Korean Journal of Ophthalmology2014 · 제28권 제4호

이 간행물의 다른 논문 (14건)