본문 바로가기
KERD
논문KCI 등재

The Impact of Learning Curve on Flap Thickness Outcome in Femtosecond Laser-assisted Laser In Situ Keratomileusis Performed with New LenSx Dual Platform

2

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류안과학

초록

Purpose: To evaluate the effect of learning curve on flap thickness (FT) outcome in femtosecond (FS) laser-assisted laser insitu keratomileusis (LASIK) operation for myopia performed with recently introduced LenSx dual platform using curved applanationcone. Methods: Seventy eyes of 36 patients with myopia or myopic astigmatism operated with FS laser-assisted LASIK with recentlyintroduced LenSx dual platform were evaluated in this retrospective study. Operations were divided into two groups: first20 operations (20 eyes of 10 patients) and next 50 operations (50 eyes of 26 patients). Data on patient demographics, preoperativeand postoperative keratometric and aberrometric parameters, and FT related outcome, including mean central FT,mean total FT, intra-FT range, and FT homogeneity were compared in study groups. Results: Except for significantly lower preoperative steepest keratometry values in the next 50 operations versus first 20operations (p = 0.033), no significant difference was noted between study groups in terms of preoperative and postoperativeparameters. When compared to first 20 operations, next 50 operations were associated with significantly higher values formean central FT (median, 123 μm vs. 114 μm; p = 0.007) and mean total FT (median, 123 μm vs. 113 μm; p = 0.015), whereassignificantly lower intra-FT range (median, 4.0 μm vs. 4.5 μm; p = 0.003). Conclusions: In conclusion, our findings related to FS laser-assisted LASIK surgery for myopia with new LenSx dual platformusing curved applanation cone revealed significant impact of learning curve on the corneal FT outcome in terms of closer FTto the intended value and lower intra-flap range.

Abstract

Purpose: To evaluate the effect of learning curve on flap thickness (FT) outcome in femtosecond (FS) laser-assisted laser insitu keratomileusis (LASIK) operation for myopia performed with recently introduced LenSx dual platform using curved applanationcone. Methods: Seventy eyes of 36 patients with myopia or myopic astigmatism operated with FS laser-assisted LASIK with recentlyintroduced LenSx dual platform were evaluated in this retrospective study. Operations were divided into two groups: first20 operations (20 eyes of 10 patients) and next 50 operations (50 eyes of 26 patients). Data on patient demographics, preoperativeand postoperative keratometric and aberrometric parameters, and FT related outcome, including mean central FT,mean total FT, intra-FT range, and FT homogeneity were compared in study groups. Results: Except for significantly lower preoperative steepest keratometry values in the next 50 operations versus first 20operations (p = 0.033), no significant difference was noted between study groups in terms of preoperative and postoperativeparameters. When compared to first 20 operations, next 50 operations were associated with significantly higher values formean central FT (median, 123 μm vs. 114 μm; p = 0.007) and mean total FT (median, 123 μm vs. 113 μm; p = 0.015), whereassignificantly lower intra-FT range (median, 4.0 μm vs. 4.5 μm; p = 0.003). Conclusions: In conclusion, our findings related to FS laser-assisted LASIK surgery for myopia with new LenSx dual platformusing curved applanation cone revealed significant impact of learning curve on the corneal FT outcome in terms of closer FTto the intended value and lower intra-flap range.

참고문헌 (23)

  1. Sugar A, "Laser in situ keratomileusis for myopia and astigmatism : safety and efficacy : a report by the American Academy of Ophthalmology", Ophthalmology, 109, pp.175~187 (2002)
  2. Varley GA, "LASIK for hyperopia, hyperopic astigmatism, and mixed astigmatism: a report by the American Academy of Ophthalmology", Ophthalmology, 111, pp.1604~1617 (2004)
  3. Huhtala A, "Femtosecond lasers for laser in situ keratomileusis : a systematic review and meta-analysis", Clin Ophthalmol, 10, pp.393~404 (2016)
  4. Santhiago MR, "Association between the percent tissue altered and post-laser in situ keratomileusis ectasia in eyes with normal preoperative topography", Am J Ophthalmol, 158, pp.87~95 (2014)
  5. Parafita-Fernandez A, "Two femtosecond laser LASIK platforms: comparison of evolution of visual acuity, flap thickness, and stromal optical density", Cornea, 38, pp.98~104 (2019)
  6. Pietila J, "Flap characteristics, predictability, and safety of the Ziemer FEMTO LDV femtosecond laser with the disposable suction ring for LASIK", Eye (Lond), 28, pp.66~71 (2014)
  7. Stonecipher K, "Advances in refractive surgery: microkeratome and femtosecond laser flap creation in relation to safety, efficacy, predictability, and biomechanical stability", Curr Opin Ophthalmol, 17, pp.368~372 (2006)
  8. Farjo AA, "Femtosecond lasers for LASIK flap creation : a report by the American Academy of Ophthalmology", Ophthalmology, 120, pp.e5~e20 (2013)
  9. Juhasz E, "Analysis of planned and postoperatively measured flap thickness after LASIK using the LenSx multifunctional femtosecond laser system", J Refract Surg, 30, pp.622~626 (2014)
  10. Wu BM, "A comparison of different operating systems for femtosecond lasers in cataract surgery", J Ophthalmol, 2015, pp.616478~ (2015)
  11. Garcia-Gonzalez M, "Comparison of visual outcomes and flap morphology using 2 femtosecond-laser platforms", J Cataract Refract Surg, 44, pp.78~84 (2018)
  12. Stahl JE, "Anterior segment OCT analysis of thin IntraLase femtosecond flaps", J Refract Surg, 23, pp.555~558 (2007)
  13. Rocha KM, "Analysis of microkeratome thin flap architecture using Fourier-domain optical coherence tomography", J Refract Surg, 27, pp.759~763 (2011)
  14. Sutton G, "Accuracy and precision of LASIK flap thickness using the IntraLase femtosecond laser in 1000consecutive cases", J Refract Surg, 24, pp.802~806 (2008)
  15. Chan Young Kim, "Factors Influencing Corneal Flap Thickness in Laser In Situ Keratomileusis with a Femtosecond Laser", Korean Journal of Ophthalmology, 25(1), pp.8~14 (2011), 대한안과학회
  16. Arbelaez MC, "Nidek MK 2000 microkeratome clinical evaluation", J Refract Surg, 18(3 Suppl), pp.S357~S60 (2002)
  17. Shemesh G, "Predictability of corneal flap thickness in laser in situ keratomileusis using three different microkeratomes", J Refract Surg, 18(3 Suppl), pp.S347~51 (2002)
  18. Kezirian GM, "Comparison of the IntraLase femtosecond laser and mechanical keratomes for laser in situ keratomileusis", J Cataract Refract Surg, 30, pp.804~811 (2004)
  19. Zhang XX, "Corneal flap morphological analysis using anterior segment optical coherence tomography in laser in situ keratomileusis with femtosecond lasers versus mechanical microkeratome", Int J Ophthalmol, 5, pp.69~73 (2012)
  20. Reinstein DZ, "Transitioning from mechanical microkeratome to femtosecond laser flap creation : visual outcomes of an experienced and a novice LASIK surgeon", J Cataract Refract Surg, 38, pp.1788~1795 (2012)
  21. Rosas Salaroli CH, "Repeatability of laser in situ keratomileusis flap thickness measurement by Fourier-domain optical coherence tomography", J Cataract Refract Surg, 37, pp.649~654 (2011)
  22. Binder PS, "Flap dimensions created with the IntraLase FS laser", J Cataract Refract Surg, 30, pp.26~32 (2004)
  23. Garcia-Gonzalez M, "Flap thickness in femtosecond laser", J Refract Surg, 31, pp.140~ (2015)

관련 논문AI추천

Factors Influencing Corneal Flap Thickness in Laser In Situ Keratomileusis with a Femtosecond Laser정소향, 주천기, Chan Young Kim, Ji Hye Song, Kyoung Sun Na대한안과학회 · Korean Journal of Ophthalmology2011 · 제25권 제1호Comparison of Laser In Situ Keratomileusis Flap Morphology and Predictability by WaveLight FS200 Femtosecond Laser and Moria Microkeratome: An Anterior Segment Optical Coherence Tomography StudyMahmoud A. Abdelsalam, Mohamed A. Nassr, Mohamed S. Hussein, Zeiad H. Eldaly대한안과학회 · Korean Journal of Ophthalmology2019 · 제33권 제2호Factors Affecting Long-term Myopic Regression after Laser In Situ Keratomileusis and Laser-assisted Subepithelial Keratectomy for Moderate Myopia나경선, 주천기, Sung A Lim, Yooyeon Park, Yu Jin Cheong대한안과학회 · Korean Journal of Ophthalmology2016 · 제30권 제2호Comparison of Corneal Wavefront-optimized and Wavefront-guided Alcohol-assisted Photorefractive Keratectomy Using Schwind Amaris 750S Laser for Myopia정소향, Jehyung Hwang, Min-Ji Kang대한안과학회 · Korean Journal of Ophthalmology2020 · 제34권 제3호The Changes of Posterior Corneal Surface and High-Order Aberrations after Refractive Surgery in Moderate Myopia김미금, 위원량, 이상목, 이진학, 이현주, Min Joung Lee대한안과학회 · Korean Journal of Ophthalmology2007 · 제21권 제3호Higher Order Aberrations of the Corneal Surface after Laser Subepithelial Keratomileusis오한진, 윤경철, 정현호, 지영석대한안과학회 · Korean Journal of Ophthalmology2014 · 제28권 제4호

이 간행물의 다른 논문 (13건)