Purpose: To evaluate the association between age and peripapillary retinal nerve fiber layer (RNFL) thickness measured by Cirrus high-definition (HD) spectral domain optical coherence tomography (OCT) in healthy Korean subjects. Methods: A total of 302 eyes from 155 healthy Korean subjects (age range, 20 to 79 years) underwent RNFL thickness measurements using the Cirrus HD-OCT. Average, quadrant, and clock-hour RNFL thickness parameters were analyzed in terms of age using linear mixed effect models. Results: Average RNFL demonstrated a slope of -2.1 μm per decade of age (p < 0.001). In quadrant analysis,superior (-3.4 μm/decade, p < 0.001) and inferior (-2.9 μm/decade, p < 0.001) quadrants showed steeper slopes, whereas temporal (-1.1 μm/decade, p < 0.001) and nasal (-1.0 μm/decade, p < 0.001) quadrants revealed shallower slopes. Among the 12 clock-hour sectors, clock hours 6 (-4.5 μm/decade, p < 0.001) and 1 (-4.1μm/decade, p < 0.001) showed the greatest tendency to decline with age; RNFLs of the 3 (-0.2 μm/decade, p = 0.391) and 4 (-0.6 μm/decade, p = 0.052) o’clock hour sectors did not show significant decay. Conclusions: RNFL thickness was associated with age, especially in superior and inferior areas. The topographic distribution of correlation between age and RNFL thickness was not uniform.

Abstract

Purpose: To evaluate the association between age and peripapillary retinal nerve fiber layer (RNFL) thickness measured by Cirrus high-definition (HD) spectral domain optical coherence tomography (OCT) in healthy Korean subjects. Methods: A total of 302 eyes from 155 healthy Korean subjects (age range, 20 to 79 years) underwent RNFL thickness measurements using the Cirrus HD-OCT. Average, quadrant, and clock-hour RNFL thickness parameters were analyzed in terms of age using linear mixed effect models. Results: Average RNFL demonstrated a slope of -2.1 μm per decade of age (p < 0.001). In quadrant analysis,superior (-3.4 μm/decade, p < 0.001) and inferior (-2.9 μm/decade, p < 0.001) quadrants showed steeper slopes, whereas temporal (-1.1 μm/decade, p < 0.001) and nasal (-1.0 μm/decade, p < 0.001) quadrants revealed shallower slopes. Among the 12 clock-hour sectors, clock hours 6 (-4.5 μm/decade, p < 0.001) and 1 (-4.1μm/decade, p < 0.001) showed the greatest tendency to decline with age; RNFLs of the 3 (-0.2 μm/decade, p = 0.391) and 4 (-0.6 μm/decade, p = 0.052) o’clock hour sectors did not show significant decay. Conclusions: RNFL thickness was associated with age, especially in superior and inferior areas. The topographic distribution of correlation between age and RNFL thickness was not uniform.

참고문헌 (25)

  1. Schuman JS, "Quantificationof nerve fiber layer thickness in normal and glaucomatouseyes using optical coherence tomography", Arch Ophthalmol, 113, pp.586~596 (1995)
  2. Lee EJ, "Trend-based analysisof retin al nerve fiber layer thickness measured by opticalcoherence tomography in eyes with localized nerve fiberlayer defects", Invest Ophthalmol Vis Sci, 52, pp.1138~1144 (2011)
  3. Leung CK, "Evaluation of retinalnerve fiber layer progression in glaucoma a prospectiveanalysis with neuroretinal rim and visual field progression", Ophthalmology, 118, pp.1551~1557 (2011)
  4. Dolman CL, "Aging of theoptic nerve", Arch Ophthalmol, 98, pp.2053~2058 (1980)
  5. Balazsi AG, "The effect of ageon the nerve fiber population of the human optic nerve", AmJ Ophthalmol, 97, pp.760~766 (1984)
  6. Johnson BM, "Age-related decline ofhuman optic nerve axon populations", Age, 10, pp.5~9 (1987)
  7. Jonas JB, "Histomorphometry of the human opticnerve", Invest Ophthalmol Vis Sci, 31, pp.736~744 (1990)
  8. Frenkel S, "Histological measurementof retinal nerve fibre layer thickness", Eye (Lond), 19, pp.491~498 (2005)
  9. Chi QM, "Evaluation of the effectof aging on the retinal nerve fiber layer thickness usingscanning laser polarimetry", J Glaucoma, 4, pp.406~413 (1995)
  10. Toprak AB, "Relation of optic disc topographyand age to thickness of retinal nerve fibre layer as measuredusing scanning laser polarimetry, in normal subjects", Br J Ophthalmol, 84, pp.473~478 (2000)
  11. Poinoosawmy D, "Variation ofnerve fibre layer thickness measurements with age andethnicity by scanning laser polarimetry", Br J Ophthalmol, 81, pp.350~354 (1997)
  12. Da Pozzo S, "The effect ofageing on retinal nerve fibre layer thickness: an evaluationby scanning laser polarimetry with variable corneal compensation", Acta Ophthalmol Scand, 84, pp.375~379 (2006)
  13. Schuman JS, "Quantificationof nerve fiber layer thickness in normal and glaucomatouseyes using optical coherence tomography", Arch Ophthalmol, 113, pp.586~596 (1995)
  14. Varma R, "Optical tomography-measuredretinal nerve fiber layer thickness in normal latinos", InvestOphthalmol Vis Sci, 44, pp.3369~3373 (2003)
  15. Budenz DL, "Determinantsof normal retinal nerve fiber layer thickness measured byStratus OCT", Ophthalmology, 114, pp.1046~1052 (2007)
  16. Parikh RS, "Normal age-relateddecay of retinal nerve fiber layer thickness", Ophthalmology, 114, pp.921~926 (2007)
  17. Feuer WJ, "Topographicdifferences in the age-related changes in the retinal nervefiber layer of normal eyes measured by Stratus optical coherencetomography", J Glaucoma, 20, pp.133~138 (2011)
  18. Sung KR, "Effects of ageon optical coherence tomography measurements of healthyretinal nerve fiber layer, macula, and optic nerve head", Ophthalmology, 116, pp.1119~1124 (2009)
  19. Mok KH, "Retinal nerve fiber layer measurementof the Hong Kong Chinese population by opticalcoherence tomography", J Glaucoma, 11, pp.481~483 (2002)
  20. Kanamori A, "Evaluation of theeffect of aging on retinal nerve fiber layer thickness measuredby optical coherence tomography", Ophthalmologica, 217, pp.273~278 (2003)
  21. Kanno M, "Peripapillaryretinal nerve fiber layer thickness in normal Japaneseeyes measured with optical coherence tomography", Jpn JOphthalmol, 54, pp.36~42 (2010)
  22. Bendschneider D, "Retinalnerve fiber layer thickness in normals measured by spectraldomain OCT", J Glaucoma, 19, pp.475~482 (2010)
  23. Knight OJ, "Comparisonof retinal nerve fiber layer measurements using timedomain and spectral domain optical coherent tomography", Ophthalmology, 116, pp.1271~1277 (2009)
  24. Sung KR, "Comparison ofretinal nerve fiber layer thickness measured by Cirrus HDand Stratus optical coherence tomography", Ophthalmology, 116, pp.1264~1270 (2009)
  25. Mikelberg FS, "The normalhuman optic nerve. Axon count and axon diameter distribution", Ophthalmology, 96, pp.1325~1328 (1989)

관련 논문AI추천

이 간행물의 다른 논문 (15건)