Age and Retinal Nerve Fiber Layer Thickness Measured by Spectral Domain Optical Coherence Tomography
2
조회
0
다운로드
5
인용
0
참고문헌
키워드
초록
Purpose: To evaluate the association between age and peripapillary retinal nerve fiber layer (RNFL) thickness measured by Cirrus high-definition (HD) spectral domain optical coherence tomography (OCT) in healthy Korean subjects. Methods: A total of 302 eyes from 155 healthy Korean subjects (age range, 20 to 79 years) underwent RNFL thickness measurements using the Cirrus HD-OCT. Average, quadrant, and clock-hour RNFL thickness parameters were analyzed in terms of age using linear mixed effect models. Results: Average RNFL demonstrated a slope of -2.1 μm per decade of age (p < 0.001). In quadrant analysis,superior (-3.4 μm/decade, p < 0.001) and inferior (-2.9 μm/decade, p < 0.001) quadrants showed steeper slopes, whereas temporal (-1.1 μm/decade, p < 0.001) and nasal (-1.0 μm/decade, p < 0.001) quadrants revealed shallower slopes. Among the 12 clock-hour sectors, clock hours 6 (-4.5 μm/decade, p < 0.001) and 1 (-4.1μm/decade, p < 0.001) showed the greatest tendency to decline with age; RNFLs of the 3 (-0.2 μm/decade, p = 0.391) and 4 (-0.6 μm/decade, p = 0.052) o’clock hour sectors did not show significant decay. Conclusions: RNFL thickness was associated with age, especially in superior and inferior areas. The topographic distribution of correlation between age and RNFL thickness was not uniform.
Abstract
Purpose: To evaluate the association between age and peripapillary retinal nerve fiber layer (RNFL) thickness measured by Cirrus high-definition (HD) spectral domain optical coherence tomography (OCT) in healthy Korean subjects. Methods: A total of 302 eyes from 155 healthy Korean subjects (age range, 20 to 79 years) underwent RNFL thickness measurements using the Cirrus HD-OCT. Average, quadrant, and clock-hour RNFL thickness parameters were analyzed in terms of age using linear mixed effect models. Results: Average RNFL demonstrated a slope of -2.1 μm per decade of age (p < 0.001). In quadrant analysis,superior (-3.4 μm/decade, p < 0.001) and inferior (-2.9 μm/decade, p < 0.001) quadrants showed steeper slopes, whereas temporal (-1.1 μm/decade, p < 0.001) and nasal (-1.0 μm/decade, p < 0.001) quadrants revealed shallower slopes. Among the 12 clock-hour sectors, clock hours 6 (-4.5 μm/decade, p < 0.001) and 1 (-4.1μm/decade, p < 0.001) showed the greatest tendency to decline with age; RNFLs of the 3 (-0.2 μm/decade, p = 0.391) and 4 (-0.6 μm/decade, p = 0.052) o’clock hour sectors did not show significant decay. Conclusions: RNFL thickness was associated with age, especially in superior and inferior areas. The topographic distribution of correlation between age and RNFL thickness was not uniform.
참고문헌 (25)
- Schuman JS, "Quantificationof nerve fiber layer thickness in normal and glaucomatouseyes using optical coherence tomography", Arch Ophthalmol, 113, pp.586~596 (1995)
- Lee EJ, "Trend-based analysisof retin al nerve fiber layer thickness measured by opticalcoherence tomography in eyes with localized nerve fiberlayer defects", Invest Ophthalmol Vis Sci, 52, pp.1138~1144 (2011)
- Leung CK, "Evaluation of retinalnerve fiber layer progression in glaucoma a prospectiveanalysis with neuroretinal rim and visual field progression", Ophthalmology, 118, pp.1551~1557 (2011)
- Dolman CL, "Aging of theoptic nerve", Arch Ophthalmol, 98, pp.2053~2058 (1980)
- Balazsi AG, "The effect of ageon the nerve fiber population of the human optic nerve", AmJ Ophthalmol, 97, pp.760~766 (1984)
- Johnson BM, "Age-related decline ofhuman optic nerve axon populations", Age, 10, pp.5~9 (1987)
- Jonas JB, "Histomorphometry of the human opticnerve", Invest Ophthalmol Vis Sci, 31, pp.736~744 (1990)
- Frenkel S, "Histological measurementof retinal nerve fibre layer thickness", Eye (Lond), 19, pp.491~498 (2005)
- Chi QM, "Evaluation of the effectof aging on the retinal nerve fiber layer thickness usingscanning laser polarimetry", J Glaucoma, 4, pp.406~413 (1995)
- Toprak AB, "Relation of optic disc topographyand age to thickness of retinal nerve fibre layer as measuredusing scanning laser polarimetry, in normal subjects", Br J Ophthalmol, 84, pp.473~478 (2000)
- Poinoosawmy D, "Variation ofnerve fibre layer thickness measurements with age andethnicity by scanning laser polarimetry", Br J Ophthalmol, 81, pp.350~354 (1997)
- Da Pozzo S, "The effect ofageing on retinal nerve fibre layer thickness: an evaluationby scanning laser polarimetry with variable corneal compensation", Acta Ophthalmol Scand, 84, pp.375~379 (2006)
- Schuman JS, "Quantificationof nerve fiber layer thickness in normal and glaucomatouseyes using optical coherence tomography", Arch Ophthalmol, 113, pp.586~596 (1995)
- Varma R, "Optical tomography-measuredretinal nerve fiber layer thickness in normal latinos", InvestOphthalmol Vis Sci, 44, pp.3369~3373 (2003)
- Budenz DL, "Determinantsof normal retinal nerve fiber layer thickness measured byStratus OCT", Ophthalmology, 114, pp.1046~1052 (2007)
- Parikh RS, "Normal age-relateddecay of retinal nerve fiber layer thickness", Ophthalmology, 114, pp.921~926 (2007)
- Feuer WJ, "Topographicdifferences in the age-related changes in the retinal nervefiber layer of normal eyes measured by Stratus optical coherencetomography", J Glaucoma, 20, pp.133~138 (2011)
- Sung KR, "Effects of ageon optical coherence tomography measurements of healthyretinal nerve fiber layer, macula, and optic nerve head", Ophthalmology, 116, pp.1119~1124 (2009)
- Mok KH, "Retinal nerve fiber layer measurementof the Hong Kong Chinese population by opticalcoherence tomography", J Glaucoma, 11, pp.481~483 (2002)
- Kanamori A, "Evaluation of theeffect of aging on retinal nerve fiber layer thickness measuredby optical coherence tomography", Ophthalmologica, 217, pp.273~278 (2003)
- Kanno M, "Peripapillaryretinal nerve fiber layer thickness in normal Japaneseeyes measured with optical coherence tomography", Jpn JOphthalmol, 54, pp.36~42 (2010)
- Bendschneider D, "Retinalnerve fiber layer thickness in normals measured by spectraldomain OCT", J Glaucoma, 19, pp.475~482 (2010)
- Knight OJ, "Comparisonof retinal nerve fiber layer measurements using timedomain and spectral domain optical coherent tomography", Ophthalmology, 116, pp.1271~1277 (2009)
- Sung KR, "Comparison ofretinal nerve fiber layer thickness measured by Cirrus HDand Stratus optical coherence tomography", Ophthalmology, 116, pp.1264~1270 (2009)
- Mikelberg FS, "The normalhuman optic nerve. Axon count and axon diameter distribution", Ophthalmology, 96, pp.1325~1328 (1989)
