Relationship between Peripapillary Retinal Nerve Fiber Layer Thickness Measured by Optical Coherence Tomography and Visual Field Severity Indices
1
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Purpose: Though there are many reports regarding the structure-function relationship in glaucoma, they are too complicated to apply to the routine clinical setting. The aim of this study was to investigate the direct relationship between peripapillary retinal nerve fiber layer (RNFL) thickness measured by optical coherence tomography (OCT) and visual field (VF) severity indices computed by standard automated perimetry. Methods: This cross-sectional comparative study included 104 glaucomatous patients and 59 healthy subjects. Peripapillary RNFL thickness was measured by spectral domain (SD) and time domain (TD) OCTs. Four glaucoma VF severity indices, including mean deviation (MD), pattern standard deviation (PSD), Collaborative Initial Glaucoma Treatment Study (CIGTS) VF score, and Advanced Glaucoma Intervention Study (AGIS) VF score, were calculated using standard automated perimetry. The Pearson’s correlation coefficients (r) between the average and quadrants of peripapillary RNFL thicknesses and the four VF severity indices were calculated. Results: In glaucomatous eyes, the r value between the average RNFL thickness measured by SD OCT and each VF severity index were 0.562, -0.514, -0.577, and -0.567 for the MD, PSD, CIGTS VF score, and AGIS VF score, respectively (all p < 0.001). Among each quadrant, the inferior RNFL thickness showed the largest r value; 0.587, -0.552, -0.613, and -0.598 for the MD, PSD, CIGTS VF score, and AGIS VF score, respectively (all p < 0.001). Measurements by TD OCT showed similar strengths of association with SD OCT. Conclusions: Moderate correlation was identified between peripapillary RNFL thicknesses measured by SD/TD OCT and glaucoma VF severity indices. Among each quadrant, the inferior RNFL thickness showed the greatest association with glaucoma VF severity indices. There was no significant difference according to the type of VF severity index or the type of OCTs.
Abstract
Purpose: Though there are many reports regarding the structure-function relationship in glaucoma, they are toocomplicated to apply to the routine clinical setting. The aim of this study was to investigate the direct relationshipbetween peripapillary retinal nerve fiber layer (RNFL) thickness measured by optical coherence tomography(OCT) and visual field (VF) severity indices computed by standard automated perimetry. Methods: This cross-sectional comparative study included 104 glaucomatous patients and 59 healthy subjects. Peripapillary RNFL thickness was measured by spectral domain (SD) and time domain (TD) OCTs. Four glaucomaVF severity indices, including mean deviation (MD), pattern standard deviation (PSD), Collaborative InitialGlaucoma Treatment Study (CIGTS) VF score, and Advanced Glaucoma Intervention Study (AGIS) VF score,were calculated using standard automated perimetry. The Pearson’s correlation coefficients (r) between theaverage and quadrants of peripapillary RNFL thicknesses and the four VF severity indices were calculated. Results: In glaucomatous eyes, the r value between the average RNFL thickness measured by SD OCT andeach VF severity index were 0.562, -0.514, -0.577, and -0.567 for the MD, PSD, CIGTS VF score, and AGISVF score, respectively (all p < 0.001). Among each quadrant, the inferior RNFL thickness showed the largest rvalue; 0.587, -0.552, -0.613, and -0.598 for the MD, PSD, CIGTS VF score, and AGIS VF score, respectively (allp < 0.001). Measurements by TD OCT showed similar strengths of association with SD OCT. Conclusions: Moderate correlation was identified between peripapillary RNFL thicknesses measured by SD/TDOCT and glaucoma VF severity indices. Among each quadrant, the inferior RNFL thickness showed the greatestassociation with glaucoma VF severity indices. There was no significant difference according to the typeof VF severity index or the type of OCTs.
참고문헌 (23)
- Sommer A, "Clinically detectable nerve fiber atrophy precedes the onset of glaucomatous field loss", Arch Ophthalmol, 109, pp.77~83 (1991)
- Johnson CA, "The relationship between structural and functional alterations in glaucoma:a review", Semin Ophthalmol, 15, pp.221~233 (2000)
- Harwerth RS, "The relationship between nerve fiber layer and perimetry measurements", Invest Ophthalmol Vis Sci, 48, pp.763~773 (2007)
- Hood DC, "A framework for comparing structural and functional measures of glaucomatous damage", Prog Retin Eye Res, 26, pp.688~710 (2007)
- Hong S, "Early glaucoma detection using the Humphrey Matrix Perimeter, GDx VCC, Stratus OCT, and retinal nerve fiber layer photography", Ophthalmology, 114, pp.210~215 (2007)
- Huang D, "Optical coherence tomography", Science, 254, pp.1178~1181 (1991)
- Hee MR, "Optical coherence tomography of the human retina", Arch Ophthalmol, 113, pp.325~332 (1995)
- Menke MN, "Reproducibility of nerve fiber layer thickness measurements using 3D fourier-domain OCT", Invest Ophthalmol Vis Sci, 49, pp.5386~5391 (2008)
- Pagliara MM, "The role of OCT in glaucoma management", Prog Brain Res, 173, pp.139~148 (2008)
- Vizzeri G, "Agreement between spectral-domain and time-domain OCT for measuring RNFL thickness", Br J Ophthalmol, 93, pp.775~781 (2009)
- Knight OJ, "Comparison of retinal nerve fiber layer measurements using time domain and spectral domain optical coherent tomography", Ophthalmology, 116, pp.1271~1277 (2009)
- Kim JS, "Retinal nerve fiber layer thickness measurement comparability between time domain optical coherence tomography (OCT) and spectral domain OCT", Invest Ophthalmol Vis Sci, 51, pp.896~902 (2010)
- Lee JR, "Structure-function relationships in normal and glaucomatous eyes determined by time- and spectral-domain optical coherence tomography", Invest Ophthalmol Vis Sci, 51, pp.6424~6430 (2010)
- Investigators AGIS, "Advanced Glaucoma Intervention Study. 2. Visual field test scoring and reliability", Ophthalmology, 101, pp.1445~1455 (1994)
- Gillespie BW, "The collaborative initial glaucoma treatment study: baseline visual field and test-retest variability", Invest Ophthalmol Vis Sci, 44, pp.2613~2620 (2003)
- 홍사민, "Evaluation of a New Scoring System for Retinal Nerve Fiber Layer Photography Using HRA1 in 964 Eyes", Korean Journal of Ophthalmology, 21(4), pp.216~221 (2007), 대한안과학회
- Budenz DL, "Reproducibility of peripapillary retinal nerve fiber thickness measurements with stratus OCT in glaucomatous eyes", Ophthalmology, 115, pp.661~666 (2008)
- Budenz DL, "Determinants of normal retinal nerve fiber layer thickness measured by Stratus OCT", Ophthalmology, 114, pp.1046~1052 (2007)
- Parikh RS, "Normal age-related decay of retinal nerve fiber layer thickness", Ophthalmology, 114, pp.921~926 (2007)
- Nagai-Kusuhara A, "Association of retinal nerve fibre layer thickness measured by confocal scanning laser ophthalmoscopy and optical coherence tomography with disc size and axial length", Br J Ophthalmol, 92, pp.186~190 (2008)
- Savini G, "Influence of pupil size and cataract on retinal nerve fiber layer thickness measurements by Stratus OCT", J Glaucoma, 15, pp.336~340 (2006)
- Leung CK, "Comparative study of retinal nerve fiber layer measurement by StratusOCT and GDx VCC, I: correlation analysis in glaucoma", Invest Ophthalmol Vis Sci, 46, pp.3214~3220 (2005)
- Leung CK, "Retinal nerve fiber layer imaging with spectral-domain optical coherence tomography: a variability and diagnostic performance study", Ophthalmology, 116, pp.1257~1263 (2009)
