본문 바로가기
KERD
논문KCI 등재

Inter-Device Agreement of Retinal Nerve Fiber Layer Thickness Measurements Using Spectral Domain Cirrus HD OCT

2

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류안과학

초록

Purpose: To assess the inter-device agreement of peripapillary retinal nerve fiber layer (RNFL) thickness measurements by 2 spectral domain Cirrus HD optical coherence tomography (OCT) devices in healthy Korean subjects. Methods: Eleven eyes of 11 healthy volunteers were enrolled in the present study. Each eye was scanned with the Optic Disc Cube 200 × 200 scan of 2 Cirrus HD OCT devices for peripapillary RNFL thickness calculation. The inter-device agreements of the 2 Cirrus HD OCTs for average, quadrant, and clock-hour RNFL thickness values were determined with Wilcoxon signed rank test, Friedman test, Cronbach’s alpha (α), intraclass correlation coefficient (ICC), coefficient of variation (COV), and Bland-Altman plot. Results: The mean age of the participants was 25.82 ± 3.28 years and all had a 0.00 logarithm of the minimum angle of resolution of best-corrected visual acuity. The signal strengths of scans from the 2 Cirrus HD OCT were not significantly different (p = 0.317). The inter-device agreement of average RNFL thickness was excellent (α, 0.940;ICC, 0.945; COV, 2.45 ± 1.52%). However, the agreement of nasal quadrant RNFL thickness was not very good (α, 0.715; ICC, 0.716; COV, 5.72 ± 4.64%). Additionally, on the Bland-Atman plot, the extent of agreement of the 2 Cirrus HD OCTs for RNFL thickness was variable according to scanned sectors. Conclusions: The inter-device agreement of 2 spectral domain Cirrus HD OCT devices for peripapillary RNFL thickness measurements was generally excellent but variable according to the scanned area. Thus, physicians should consider this fact before judging a change of RNFL thicknesses if they were measured by different OCT devices.

Abstract

Purpose: To assess the inter-device agreement of peripapillary retinal nerve fiber layer (RNFL) thickness measurements by 2 spectral domain Cirrus HD optical coherence tomography (OCT) devices in healthy Korean subjects. Methods: Eleven eyes of 11 healthy volunteers were enrolled in the present study. Each eye was scanned with the Optic Disc Cube 200 × 200 scan of 2 Cirrus HD OCT devices for peripapillary RNFL thickness calculation. The inter-device agreements of the 2 Cirrus HD OCTs for average, quadrant, and clock-hour RNFL thickness values were determined with Wilcoxon signed rank test, Friedman test, Cronbach’s alpha (α), intraclass correlation coefficient (ICC), coefficient of variation (COV), and Bland-Altman plot. Results: The mean age of the participants was 25.82 ± 3.28 years and all had a 0.00 logarithm of the minimum angle of resolution of best-corrected visual acuity. The signal strengths of scans from the 2 Cirrus HD OCT were not significantly different (p = 0.317). The inter-device agreement of average RNFL thickness was excellent (α, 0.940;ICC, 0.945; COV, 2.45 ± 1.52%). However, the agreement of nasal quadrant RNFL thickness was not very good (α, 0.715; ICC, 0.716; COV, 5.72 ± 4.64%). Additionally, on the Bland-Atman plot, the extent of agreement of the 2 Cirrus HD OCTs for RNFL thickness was variable according to scanned sectors. Conclusions: The inter-device agreement of 2 spectral domain Cirrus HD OCT devices for peripapillary RNFL thickness measurements was generally excellent but variable according to the scanned area. Thus, physicians should consider this fact before judging a change of RNFL thicknesses if they were measured by different OCT devices.

참고문헌 (10)

  1. Schuman JS, "Quantification of nerve fiber layer thickness in normal and glaucomatous eyes using optical coherence tomography", Arch Ophthalmol, 113, pp.586~596 (1995)
  2. Pieroth L, "Evaluation of focal defects of the nerve fiber layer using optical coherence tomography", Ophthalmology, 106, pp.570~579 (1999)
  3. Sehi M, "Assessment of retinal nerve fiber layer using optical coherence tomography and scanning laser polarimetry in progressive glaucomatous optic neuropathy", Am J Ophthalmol, 142, pp.1056~1059 (2006)
  4. Leung CK, "Longitudinal variability of optic disc and retinal nerve fiber layer measurements", Invest Ophthalmol Vis Sci, 49, pp.4886~4892 (2008)
  5. Wojtkowski M, "Ophthalmic imaging by spectral optical coherence tomography", Am J Ophthalmol, 138, pp.412~419 (2004)
  6. Chen TC, "Spectral domain optical coherence tomography:ultra-high speed,ultra-high resolution ophthalmic imaging", Arch Ophthalmol, 123, pp.1715~1720 (2005)
  7. Vizzeri G, "Spectral domain-optical coherence tomography to detect localized retinal nerve fiber layer defects in glaucomatous eyes", Opt Express, 17, pp.4004~4018 (2009)
  8. Sehi M, "A comparison of structural measurements using 2 Stratus optical coherence tomography instruments", J Glaucoma, 16, pp.287~292 (2007)
  9. Barkana Y, "Inter-device variability of the Stratus optical coherence tomography", Am J Ophthalmol, 147, pp.260~266 (2009)
  10. Bravo G, "Estimating the reliability of continuous measures with Cronbach’s alpha or the intraclass correlation coefficient:toward the integration of two traditions", J Clin Epidemiol, 44, pp.381~390 (1991)