초록
Purpose: To assess the inter-device agreement of peripapillary retinal nerve fiber layer (RNFL) thickness measurements by 2 spectral domain Cirrus HD optical coherence tomography (OCT) devices in healthy Korean subjects. Methods: Eleven eyes of 11 healthy volunteers were enrolled in the present study. Each eye was scanned with the Optic Disc Cube 200 × 200 scan of 2 Cirrus HD OCT devices for peripapillary RNFL thickness calculation. The inter-device agreements of the 2 Cirrus HD OCTs for average, quadrant, and clock-hour RNFL thickness values were determined with Wilcoxon signed rank test, Friedman test, Cronbach’s alpha (α), intraclass correlation coefficient (ICC), coefficient of variation (COV), and Bland-Altman plot. Results: The mean age of the participants was 25.82 ± 3.28 years and all had a 0.00 logarithm of the minimum angle of resolution of best-corrected visual acuity. The signal strengths of scans from the 2 Cirrus HD OCT were not significantly different (p = 0.317). The inter-device agreement of average RNFL thickness was excellent (α, 0.940;ICC, 0.945; COV, 2.45 ± 1.52%). However, the agreement of nasal quadrant RNFL thickness was not very good (α, 0.715; ICC, 0.716; COV, 5.72 ± 4.64%). Additionally, on the Bland-Atman plot, the extent of agreement of the 2 Cirrus HD OCTs for RNFL thickness was variable according to scanned sectors. Conclusions: The inter-device agreement of 2 spectral domain Cirrus HD OCT devices for peripapillary RNFL thickness measurements was generally excellent but variable according to the scanned area. Thus, physicians should consider this fact before judging a change of RNFL thicknesses if they were measured by different OCT devices.
Abstract
Purpose: To assess the inter-device agreement of peripapillary retinal nerve fiber layer (RNFL) thickness measurements by 2 spectral domain Cirrus HD optical coherence tomography (OCT) devices in healthy Korean subjects. Methods: Eleven eyes of 11 healthy volunteers were enrolled in the present study. Each eye was scanned with the Optic Disc Cube 200 × 200 scan of 2 Cirrus HD OCT devices for peripapillary RNFL thickness calculation. The inter-device agreements of the 2 Cirrus HD OCTs for average, quadrant, and clock-hour RNFL thickness values were determined with Wilcoxon signed rank test, Friedman test, Cronbach’s alpha (α), intraclass correlation coefficient (ICC), coefficient of variation (COV), and Bland-Altman plot. Results: The mean age of the participants was 25.82 ± 3.28 years and all had a 0.00 logarithm of the minimum angle of resolution of best-corrected visual acuity. The signal strengths of scans from the 2 Cirrus HD OCT were not significantly different (p = 0.317). The inter-device agreement of average RNFL thickness was excellent (α, 0.940;ICC, 0.945; COV, 2.45 ± 1.52%). However, the agreement of nasal quadrant RNFL thickness was not very good (α, 0.715; ICC, 0.716; COV, 5.72 ± 4.64%). Additionally, on the Bland-Atman plot, the extent of agreement of the 2 Cirrus HD OCTs for RNFL thickness was variable according to scanned sectors. Conclusions: The inter-device agreement of 2 spectral domain Cirrus HD OCT devices for peripapillary RNFL thickness measurements was generally excellent but variable according to the scanned area. Thus, physicians should consider this fact before judging a change of RNFL thicknesses if they were measured by different OCT devices.
참고문헌 (10)
- Schuman JS, "Quantification of nerve fiber layer thickness in normal and glaucomatous eyes using optical coherence tomography", Arch Ophthalmol, 113, pp.586~596 (1995)
- Pieroth L, "Evaluation of focal defects of the nerve fiber layer using optical coherence tomography", Ophthalmology, 106, pp.570~579 (1999)
- Sehi M, "Assessment of retinal nerve fiber layer using optical coherence tomography and scanning laser polarimetry in progressive glaucomatous optic neuropathy", Am J Ophthalmol, 142, pp.1056~1059 (2006)
- Leung CK, "Longitudinal variability of optic disc and retinal nerve fiber layer measurements", Invest Ophthalmol Vis Sci, 49, pp.4886~4892 (2008)
- Wojtkowski M, "Ophthalmic imaging by spectral optical coherence tomography", Am J Ophthalmol, 138, pp.412~419 (2004)
- Chen TC, "Spectral domain optical coherence tomography:ultra-high speed,ultra-high resolution ophthalmic imaging", Arch Ophthalmol, 123, pp.1715~1720 (2005)
- Vizzeri G, "Spectral domain-optical coherence tomography to detect localized retinal nerve fiber layer defects in glaucomatous eyes", Opt Express, 17, pp.4004~4018 (2009)
- Sehi M, "A comparison of structural measurements using 2 Stratus optical coherence tomography instruments", J Glaucoma, 16, pp.287~292 (2007)
- Barkana Y, "Inter-device variability of the Stratus optical coherence tomography", Am J Ophthalmol, 147, pp.260~266 (2009)
- Bravo G, "Estimating the reliability of continuous measures with Cronbach’s alpha or the intraclass correlation coefficient:toward the integration of two traditions", J Clin Epidemiol, 44, pp.381~390 (1991)