Purpose: We sought to establish normative ranges of the ganglion cell-inner plexiform layer (GCIPL) thickness using spectral-domain optical coherence tomography in Korean elderly individuals and to identify factors that influence GCIPL thickness. Methods: We conducted a retrospective, observational study of 114 healthy subjects (75 years old or older) who underwentcomprehensive ophthalmic examinations at a single institution. GCIPL thickness was measured with the Cirrus spectral-domainoptical coherence tomography system and automatic segmentation. Subjects were divided into two age groups: thoseyounger than 80 years and those 80 years or older, respectively. A cross-sectional analysis was adopted to evaluate associationsof GCIPL thickness with sex, age, intraocular pressure, optic disc rim area, axial length, spherical equivalent (SE) refractiveerrors, astigmatism, and body mass index. Results: The average and minimum GCIPL thicknesses were 80.3 ± 5.6 μm and 76.3 ± 5.9 μm, respectively. The GCIPL thicknesswas significantly lower in the older group than in the younger group in the inferior, inferonasal, and inferotemporal segments(all p < 0.01). A thinner average GCIPL thickness was strongly associated with increasing age (β = -2.87, p = 0.021) andthinner circumpapillary retinal nerve fiber layer thickness (β = 2.87, p < 0.001) in all segments. Conclusions: GCIPL thickness decreased with age globally and in all segments, even after 75 years of age. Thinner GCIPL wasassociated with older age and thinner circumpapillary retinal nerve fiber layer. Age-related changes should be consideredwhen using GCIPL thickness to assess glaucoma and other optic neuropathies characterized by retinal ganglion cell loss.

Abstract

Purpose: We sought to establish normative ranges of the ganglion cell-inner plexiform layer (GCIPL) thickness using spectral-domain optical coherence tomography in Korean elderly individuals and to identify factors that influence GCIPL thickness. Methods: We conducted a retrospective, observational study of 114 healthy subjects (75 years old or older) who underwentcomprehensive ophthalmic examinations at a single institution. GCIPL thickness was measured with the Cirrus spectral-domainoptical coherence tomography system and automatic segmentation. Subjects were divided into two age groups: thoseyounger than 80 years and those 80 years or older, respectively. A cross-sectional analysis was adopted to evaluate associationsof GCIPL thickness with sex, age, intraocular pressure, optic disc rim area, axial length, spherical equivalent (SE) refractiveerrors, astigmatism, and body mass index. Results: The average and minimum GCIPL thicknesses were 80.3 ± 5.6 μm and 76.3 ± 5.9 μm, respectively. The GCIPL thicknesswas significantly lower in the older group than in the younger group in the inferior, inferonasal, and inferotemporal segments(all p < 0.01). A thinner average GCIPL thickness was strongly associated with increasing age (β = -2.87, p = 0.021) andthinner circumpapillary retinal nerve fiber layer thickness (β = 2.87, p < 0.001) in all segments. Conclusions: GCIPL thickness decreased with age globally and in all segments, even after 75 years of age. Thinner GCIPL wasassociated with older age and thinner circumpapillary retinal nerve fiber layer. Age-related changes should be consideredwhen using GCIPL thickness to assess glaucoma and other optic neuropathies characterized by retinal ganglion cell loss.

참고문헌 (37)

  1. Huang D, "Optical coherence tomography", Science, 254, pp.1178~1181 (1991)
  2. Zhang X, "Longitudinal and cross-sectional analyses of age effects on retinal nerve fiber layer and ganglion cell complex thickness by Fourier-domain OCT", Transl Vis Sci Technol, 5, pp.1~ (2016)
  3. Drexler W, "Enhanced visualization of macular pathology with the use of ultrahigh-resolution optical coherence tomography", Arch Ophthalmol, 121, pp.695~706 (2003)
  4. Kim KE, "Severity-dependent association between ganglion cell inner plexiform layer thickness and macular mean sensitivity in open-angle glaucoma", Acta Ophthalmol, 92, pp.e650~e656 (2014)
  5. Kim KE, "Long-term reproducibility of macular ganglion cell analysis in clinically stable glaucoma patients", Invest Ophthalmol Vis Sci, 56, pp.4857~4864 (2015)
  6. Larrea BA, "Early axonal damage detection by ganglion cell complex analysis with optical coherence tomography in nonarteritic anterior ischaemic optic neuropathy", Graefes Arch Clin Exp Ophthalmol, 252, pp.1839~1846 (2014)
  7. Weinreb RN, "The pathophysiology and treatment of glaucoma : a review", JAMA, 311, pp.1901~1911 (2014)
  8. Mwanza JC, "Glaucoma diagnostic accuracy of ganglion cell-inner plexiform layer thickness : comparison with nerve fiber layer and optic nerve head", Ophthalmology, 119, pp.1151~1158 (2012)
  9. Nouri-Mahdavi K, "Macular ganglion cell", inner plexiform layer measurements by spectral domain optical coherence tomography for detection of early glaucoma and comparison to retinal nerve fiber layer measurements, 2013, pp.156, 1297~1307
  10. Sato S, "Correlation between the ganglion cell-inner plexiform layer thickness measured with cirrus HD-OCT and macular visual field sensitivity measured with microperimetry", Invest Ophthalmol Vis Sci, 54, pp.3046~3051 (2013)
  11. Kim HJ, "Glaucoma diagnostic ability of layer-by-layer segmented ganglion cell complex by spectral-domain optical coherence tomography", Invest Ophthalmol Vis Sci, 57, pp.4799~4805 (2016)
  12. Lee EJ, "Comparison of the pattern of retinal ganglion cell damage between patients with compressive and glaucomatous optic neuropathies", Invest Ophthalmol Vis Sci, 56, pp.7012~7020 (2015)
  13. Gonzalez-Lopez JJ, "Comparative diagnostic accuracy of ganglion cell-inner plexiform and retinal nerve fiber layer thickness measures by Cirrus and Spectralis optical coherence tomography in relapsing-remit ting multiple sclerosis", Biomed Res Int, 2014, pp.128517~ (2014)
  14. Koh VT, "Determinants of ganglion cell-inner plexiform layer thickness measured by high-definition optical coherence tomography", Invest Ophthalmol Vis Sci, 53, pp.5853~5859 (2012)
  15. Cheung CY, "Retinal ganglion cell analysis using high-definition optical coherence tomography in patients with mild cognitive impairment and Alzheimer’s disease", J Alzheimers Dis, 45, pp.45~56 (2015)
  16. Huo YJ, "Age-related changes in and determinants of macular ganglion cell-inner plexiform layer thickness in normal Chinese adults", Clin Exp Ophthalmol, 46, pp.400~406 (2018)
  17. Mwanza JC, "P rofile and predictors of normal ganglion cell-inner plexiform layer thickness measured with frequency-domain optical coherence tomography", Invest Ophthalmol Vis Sci, 52, pp.7872~7879 (2011)
  18. Knight OJ, "Effect of race, age, and axial length on optic nerve head parameters and retinal nerve fiber layer thickness measured by Cirrus HDOCT", Arch Ophthalmol, 130, pp.312~318 (2012)
  19. Mwanza JC, "Macular ganglion cell-inner plexiform layer : automated detection and thickness reproducibility with spectral domain-optical coherence tomography in glaucoma", Invest Ophthalmol Vis Sci, 52, pp.8323~8329 (2011)
  20. Kim KE, "Diagnostic classification of macular ganglion cell and retinal nerve fiber layer analysis : differentiation of false-positives from glaucoma", Ophthalmology, 122, pp.502~510 (2015)
  21. Jeong JH, "Macular ganglion cell imaging study : covariate effects on the spectral domain optical coherence tomography for glaucoma diagnosis", PLoS One, 11, pp.e0160448~ (2016)
  22. Jeoung JW, "Macular ganglion cell imaging study : glaucoma diagnostic accuracy of spectral-domain optical coherence tomography", Invest Ophthalmol Vis Sci, 54, pp.4422~4429 (2013)
  23. Leung CK, "Impact of age-related change of retinal nerve fiber layer and macular thicknesses on evaluation of glaucoma progression", Ophthalmology, 120, pp.2485~2492 (2013)
  24. Araie M, "Relationship between macular inner retinal layer thickness and corresponding retinal sensitivity in normal eyes", Invest Ophthalmol Vis Sci, 55, pp.7199~7205 (2014)
  25. Ueda K, "Effects of a xial length and age on circumpapillary retinal nerve fiber layer and inner macular parameters measured by 3 types of SDOCT instruments", J Glaucoma, 25, pp.383~389 (2016)
  26. Budenz DL, "Determinants of normal retinal nerve fiber layer thickness measured by Stratus OCT", Ophthalmology, 114, pp.1046~1052 (2007)
  27. Myers CE, "Retinal thickness measured by spectral-domain optical coherence tomography in eyes without retinal abnormalities : the Beaver Dam Eye Study", Am J Ophthalmol, 159, pp.445~456 (2015)
  28. Song WK, "Macular thickness variations with sex, age, and axial length in healthy subjects: a spectral domain-optical coherence tomography study", Invest Ophthalmol Vis Sci, 51, pp.3913~3918 (2010)
  29. Zhang C, "Relationship between ganglion cell layer thickness and estimated retinal ganglion cell counts in the glaucomatous macula", Ophthalmology, 121, pp.2371~2379 (2014)
  30. Demirkaya N, "Effect of age on individual retinal layer thickness in normal eyes as measured with spectral-domain optical coherence tomography", Invest Ophthalmol Vis Sci, 54, pp.4934~4940 (2013)
  31. Jonas JB, "Histomorphometry of the human optic nerve", Invest Ophthalmol Vis Sci, 31, pp.736~744 (1990)
  32. Varma R, "Retinal nerve fiber layer thickness in normal human eyes", Ophthalmology, 103, pp.2114~2119 (1996)
  33. Rao HL, "Predictors of normal optic nerve head, retinal nerve fiber layer, and macular parameters measured by spectral domain optical coherence tomography", Invest Ophthalmol Vis Sci, 52, pp.1103~1110 (2011)
  34. Bowd C, "Imaging of the optic disc and retinal nerve fiber layer: the effects of age, optic disc area, refractive error, and gender", J Opt Soc Am A Opt Image Sci Vis, 19, pp.197~207 (2002)
  35. Kim NR, "Determinants of perimacular inner retinal layer thickness in normal eyes measured by Fourier-domain optical coherence tomography", Invest Ophthalmol Vis Sci, 52, pp.3413~3418 (2011)
  36. Jonas JB, "Human optic nerve fiber count and optic disc size", Invest Ophthalmol Vis Sci, 33, pp.2012~2018 (1992)
  37. Quigley HA, "Larger optic nerve heads have more nerve fibers in normal monkey eyes", Arch Ophthalmol, 109, pp.1441~1443 (1991)

관련 논문AI추천

이 간행물의 다른 논문 (13건)