Rotational Stability of AcrySof Toric Intraocular Lens Over Time: Influence of Capsulorhexis Contraction
2
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Background and ObjectivesTo evaluate the rotational stability of AcrySof toric intraocular lenses (IOL) by considering lapse of postoperative time and influence of capsulorhexis contraction. Materials and MethodsA prospective, masked, single center study was conducted on 19 patients who had undergone microcoaxial cataract surgery and AcrySof toric IOL implantation. Slit-lamp retroillumination photographs of anterior segments were obtained from all patients after 1 week, 1 month and 3 months post-surgery. The degree of alteration of the postoperative IOL axis alignment and the amount of anterior capsular shrinkage were analyzed using Adobe Photoshop software. ResultsThe mean degree of toric IOL axis misalignment was 2.18 (±20.2) degrees at 3 months follow-up. Quadrant analysis of the capsulorhexis aperture area at 1 week and 1 month post-operative, showed counterclockwise IOL rotation when the capsule contraction was dominant in the haptic part as well as clockwise rotation when dominant in the non-haptic part (p = 0.015). ConclusionThe direction and degree of AcrySof toric IOL rotation differed throughout the follow-up period. Since most misalignments were found on the first post-operative day, physicians should try to minimize peri-operative risk factors that influence IOL rotation. There was also a correlation between the part of anterior capsule contraction and the direction of IOL rotation.
Abstract
Background and ObjectivesTo evaluate the rotational stability of AcrySof toric intraocular lenses (IOL) by considering lapse of postoperative time and influence of capsulorhexis contraction. Materials and MethodsA prospective, masked, single center study was conducted on 19 patients who had undergone microcoaxial cataract surgery and AcrySof toric IOL implantation. Slit-lamp retroillumination photographs of anterior segments were obtained from all patients after 1 week, 1 month and 3 months post-surgery. The degree of alteration of the postoperative IOL axis alignment and the amount of anterior capsular shrinkage were analyzed using Adobe Photoshop software. ResultsThe mean degree of toric IOL axis misalignment was 2.18 (±20.2) degrees at 3 months follow-up. Quadrant analysis of the capsulorhexis aperture area at 1 week and 1 month post-operative, showed counterclockwise IOL rotation when the capsule contraction was dominant in the haptic part as well as clockwise rotation when dominant in the non-haptic part (p = 0.015). ConclusionThe direction and degree of AcrySof toric IOL rotation differed throughout the follow-up period. Since most misalignments were found on the first post-operative day, physicians should try to minimize peri-operative risk factors that influence IOL rotation. There was also a correlation between the part of anterior capsule contraction and the direction of IOL rotation.
참고문헌 (25)
- Hoffer KJ, "Biometry of 7, 500 cataractous eyes", Am J Ophthalmol, 90, pp.360~368 (1980)
- Colin J, "Excimer laser treatment of myopic astigmatism. A comparison of three ablation programs", Ophthalmology, 105, pp.1182~1188 (1998)
- Dausch D, "Photorefractive keratectomy to correct astigmatism with myopia or hyperopia", J Cataract Refract Surg, 20(Suppl), pp.252~257 (1994)
- Salchow DJ, "Laser in situ keratomileusis for myopia and myopic astigmatism", J Cataract Refract Surg, 24, pp.175~182 (1998)
- Knorz MC, "Laser in situ keratomileusis for moderate and high myopia and myopic astigmatism", Ophthalmology, 105, pp.932~940 (1998)
- 이경민, "엑시머레이저 굴절교정수술을 이용한 백내장 수술 후 잔여 난시에 의한 부등시의 교정", 대한안과학회지, 49(10), pp.1589~1596 (2008), 대한안과학회
- Niles C, "Excimer laser photorefractive keratectomy using an erodible mask to treat myopic astigmatism", J Cataract Refract Surg, 22, pp.436~440 (1996)
- Till JS, "Toric intraocular lens implantation : 100 consecutive cases", J Cataract Refract Surg, 28, pp.295~301 (2002)
- Shimizu K, "Toric intraocular lenses : correcting astigmatism while controlling axis shift", J Cataract Refract Surg, 20, pp.523~526 (1994)
- Werblin TP, "Do three-piece PMMA IOLs rotate after implantation in the capsular bag?", J Refract Surg, 11, pp.468~471 (1995)
- Sanders DR, "Sutureless cataract surgery:an evolution toward minimally invasive technique", pp.183~197 (1992), Slack Inc
- Gills JP, "Surgical treatment of astigmatism", pp.159~164 (1994), Slack Inc
- Chang DF, "Comparative rotational stability of single-piece open-loop acrylic and plate-haptic silicone toric intraocular lenses", J Cataract Refract Surg, 34, pp.1842~1847 (2008)
- Mendicute J, "Foldable toric intraocular lens for astigmatism correction in cataract patients", J Cataract Refract Surg, 34, pp.601~607 (2008)
- Bauer NJ, "Astigmatism management in cataract surgery with the AcrySof toric intraocular lens", J Cataract Refract Surg, 34, pp.1483~1488 (2008)
- Rastogi A, "Comparative evaluation of rotational stability and visual outcome of toric intraocular lenses with and without a capsular tension ring", Indian J Ophthalmol, 66, pp.411~415 (2018)
- Zuberbuhler B, "Rotational stability of the AcrySof SA60TT toric intraocular lenses : a cohort study", BMC Ophthalmol, 8, pp.8~ (2008)
- Cravy TV, "Calculation of the change in corneal astigmatism following cataract extraction", Ophthalmic Surg, 10, pp.38~49 (1979)
- Hill W, "Monte Carlo simulation of expected outcomes with the AcrySof toric intraocular lens", BMC Ophthalmol, 8, pp.22~ (2008)
- Pärssinen O, "Compression forces of haptics of selected posterior chamber lenses", J Cataract Refract Surg, 23, pp.1237~1246 (1997)
- Strenn K, "Capsular bag shrinkage after implantation of an open-loop silicone lens and a poly(methyl methacrylate)capsule tension ring", J Cataract Refract Surg, 23, pp.1543~1547 (1997)
- Trivedi RH, "Cataract surgery: techniques, complications and management", pp.443~465 (2004), Mosby
- Elmohamady MN, "Circular YAG laser anterior capsulotomy for anterior capsule contraction syndrome", Int Ophthalmol, 39, pp.2497~2503 (2019)
- Weinand F, "Rotational stability of a single-piece hydrophobic acrylic intraocular lens : new method for high-precision rotation control", J Cataract Refract Surg, 33, pp.800~803 (2007)
- Kwartz J, "Evaluation of the long-term rotational stability of single-piece, acrylic intraocular lenses", Br J Ophthalmol, 94, pp.1003~1006 (2010)