초록

Purpose: To evaluate the long-term efficacy and rotational stability of the AcrySof toric intraocular lens (IOL) in correcting preoperative astigmatism in cataract patients. Methods: This prospective observational study included 30 eyes from 24 consecutive patients who underwent implantation of an AcrySof toric IOL with micro-coaxial cataract surgery between May 2008 and September 2008. Outcomes of visual acuity, refractive and keratometric astigmatism, and IOL rotation after 1 day, 1 month, 3 months, and long-term (mean, 13.3±5.0 months) follow-up were evaluated. Results: At final follow-up, 73.3% of eyes showed an uncorrected visual acuity of 20/25 or better. The postoperative keratometric value was not different from the preoperative value; mean refractive astigmatism was reduced to -0.28±0.38 diopter (D) from -1.28±0.48 D. The mean rotation of the toric IOL was 3.45±3.39 degrees at final follow-up. One eye (3.3%) exhibited IOL rotation of 10.3 degrees, the remaining eyes (96.7%) had IOL rotation of less than 10 degrees. Conclusions: Early postoperative and long-term follow-up showed that implantation of the AcrySof toric IOL is an effective, safe, and predictable method for managing corneal astigmatism in cataract patients.

Abstract

Purpose: To evaluate the long-term efficacy and rotational stability of the AcrySof toric intraocular lens (IOL) in correcting preoperative astigmatism in cataract patients. Methods: This prospective observational study included 30 eyes from 24 consecutive patients who underwent implantation of an AcrySof toric IOL with micro-coaxial cataract surgery between May 2008 and September 2008. Outcomes of visual acuity, refractive and keratometric astigmatism, and IOL rotation after 1 day, 1 month, 3 months, and long-term (mean, 13.3±5.0 months) follow-up were evaluated. Results: At final follow-up, 73.3% of eyes showed an uncorrected visual acuity of 20/25 or better. The postoperative keratometric value was not different from the preoperative value; mean refractive astigmatism was reduced to -0.28±0.38 diopter (D) from -1.28±0.48 D. The mean rotation of the toric IOL was 3.45±3.39 degrees at final follow-up. One eye (3.3%) exhibited IOL rotation of 10.3 degrees, the remaining eyes (96.7%) had IOL rotation of less than 10 degrees. Conclusions: Early postoperative and long-term follow-up showed that implantation of the AcrySof toric IOL is an effective, safe, and predictable method for managing corneal astigmatism in cataract patients.

참고문헌 (22)

  1. Hoffer KJ, "Biometry of 7,500 cataractous eyes", Am J Ophthalmol, 90, pp.360~368 (1980)
  2. Shimizu K, "Toric intraocular lenses: correcting astigmatism while controlling axis shift", J Cataract Refract Surg, 20, pp.523~526 (1994)
  3. Grabow HB, "Early results of 500 cases of no-stitch cataract surgery", J Cataract Refract Surg, 17(Suppl), pp.726~730 (1991)
  4. Werblin TP, "Do three-piece PMMA IOLs rotate after implantation in the capsular bag?", J Refract Surg, 11, pp.468~471 (1995)
  5. Ruhswurm I, "Astigmatism correction with a foldable toric intraocular lens in cataract patients", J Cataract Refract Surg, 26, pp.1022~1027 (2000)
  6. Sun XY, "Toric intraocular lenses for correcting astigmatism in 130 eyes", Ophthalmology, 107, pp.1776~1781 (2000)
  7. Leyland M, "Prospective evaluation of a plate haptic toric intraocular lens", Eye (Lond), 15, pp.202~205 (2001)
  8. Till JS, "Toric intraocular lens implantation: 100 consecutive cases", J Cataract Refract Surg, 28, pp.295~301 (2002)
  9. Chang DF, "Early rotational stability of the longer Staar toric intraocular lens: fifty consecutive cases", J Cataract Refract Surg, 29, pp.935~940 (2003)
  10. De Silva DJ, "Evaluation of a toric intraocular lens with a Z-haptic", J Cataract Refract Surg, 32, pp.1492~1498 (2006)
  11. Horn JD, "Status of toric intraocular lenses", Curr Opin Ophthalmol, 18, pp.58~61 (2007)
  12. Ohmi S, "Decentration associated with asymmetric capsular shrinkage and intraocular lens size", J Cataract Refract Surg, 19, pp.640~643 (1993)
  13. Strenn K, "Capsular bag shrinkage after implantation of an open-loop silicone lens and a poly (methyl methacrylate) capsule tension ring", J Cataract Refract Surg, 23, pp.1543~1547 (1997)
  14. Sanders DR, "The toric IOL. In:Sutureless cataract surgery: an evolution toward minimally invasive technique", pp.183~197 (1992), Slack, Inc
  15. Husain SE, "Computerized videokeratography and keratometry in determining intraocular lens calculations", J Cataract Refract Surg, 22, pp.362~366 (1996)
  16. Grabow HB, "Intraocular correction of refractive errors. In:Refractive keratectomy for cataract surgery and the correction of astigmatism", pp.79~115 (1994), Slack, Inc
  17. Novis C, "Astigmatism and toric intraocular lenses", Curr Opin Ophthalmol, 11, pp.47~50 (2000)
  18. Patel CK, "Postoperative intraocular lens rotation: a randomized comparison of plate and loop haptic implants", Ophthalmology, 106, pp.2190~2195 (1999)
  19. Weinand F, "Rotational stability of a single-piece hydrophobic acrylic intraocular lens: new method for high-precision rotation control", J Cataract Refract Surg, 33, pp.800~803 (2007)
  20. Zuberbuhler B, "Rotational stability of the AcrySof SA60TT toric intraocular lenses: a cohort study", BMC Ophthalmol, 8, pp.8~ (2008)
  21. Mendicute J, "Foldable toric intraocular lens for astigmatism correction in cataract patients", J Cataract Refract Surg, 34, pp.601~607 (2008)
  22. 나정화, "난시교정인공수정체 삽입 후 임상 결과", 대한안과학회지, 50(6), pp.831~838 (2009), 대한안과학회

관련 논문AI추천

이 간행물의 다른 논문 (12건)