Effect of Haptic Material and Number of Intraocular Lens on Anterior Capsule Contraction after Cataract Surgery
2
조회
0
다운로드
1
인용
0
참고문헌
키워드
초록
Purpose: To evaluate changes over time of the anterior capsule opening size after phacoemulsification, based on haptic number and composition of three acrylic intraocular lenses (IOLs). Methods: Fifty-five patients (70 eyes) were included. All underwent phacoemulsification followed by implantation of either an acrylic IOL with two-haptic (one-piece, 26 eyes; three-piece, 22 eyes), or four-haptic (one-piece, 22 eyes). The area of the anterior capsule opening size was measured one week postoperatively (baseline) and at three months. Results: There was a significant reduction in the area of the anterior capsule opening from one week as compared to three months postoperatively in all groups (p < 0.001). However, there was no significant difference in the reduction in the anterior capsule opening between the IOLs (p = 0.36). Conclusions: The number and material of the haptic of the three acrylic IOLs did not influence the degree of anterior capsule opening shrinkage.
Abstract
Purpose: To evaluate changes over time of the anterior capsule opening size after phacoemulsification, based on haptic number and composition of three acrylic intraocular lenses (IOLs). Methods: Fifty-five patients (70 eyes) were included. All underwent phacoemulsification followed by implantation of either an acrylic IOL with two-haptic (one-piece, 26 eyes; three-piece, 22 eyes), or four-haptic (one-piece, 22 eyes). The area of the anterior capsule opening size was measured one week postoperatively (baseline) and at three months. Results: There was a significant reduction in the area of the anterior capsule opening from one week as compared to three months postoperatively in all groups (p < 0.001). However, there was no significant difference in the reduction in the anterior capsule opening between the IOLs (p = 0.36). Conclusions: The number and material of the haptic of the three acrylic IOLs did not influence the degree of anterior capsule opening shrinkage.
참고문헌 (32)
- Hansen SO, "Progressive constriction of the anterior capsular opening following intact capsulorhexis", J Cataract Refract Surg, 19, pp.77~82 (1993)
- Davison JA, "Capsule contraction syndrome", J Cataract Refract Surg, 19, pp.582~589 (1993)
- Hayashi K, "Anterior capsule contraction and intraocular lens dislocation after implant surgery in eyes with retinitis pigmentosa", Ophthalmology, 105, pp.1239~1243 (1998)
- Hayashi H, "Anterior capsule contraction and intraocular lens dislocation in eyes with pseudoexfoliation syndrome", Br J Ophthalmol, 82, pp.1429~1432 (1998)
- Hayashi H, "Area reduction in the anterior capsule opening in eyes of diabetes mellitus patients", J Cataract Refract Surg, 24, pp.1105~1110 (1998)
- Ursell PG, "Anterior capsule stability in eyes with intraocular lenses made of poly(methyl methacrylate), silicone, and AcrySof", J Cataract Refract Surg, 23, pp.1532~1538 (1997)
- Gonvers M, "Change in capsulorhexis size after implantation of three types of intraocular lenses", J Cataract Refract Surg, 23, pp.231~238 (1997)
- Hayashi K, "Anterior capsule contraction and intraocular lens decentration and tilt after hydrogel lens implantation", Br J Ophthalmol, 85, pp.1294~1297 (2001)
- Hayashi K, "Effect of anterior capsule contraction on visual function after cataract surgery", J Cataract Refract Surg, 33, pp.1936~1940 (2007)
- Cochener B, "Capsule contraction after continuous curvilinear capsulorhexis: poly(methyl methacrylate) versus silicone intraocular lenses", J Cataract Refract Surg, 25, pp.1362~1369 (1999)
- Dahlhauser KF, "Anterior capsule contraction with foldable silicone intraocular lenses", J Cataract Refract Surg, 24, pp.1216~1219 (1998)
- 김재우, "유리체절제술과 백내장 동시수술에서 네지지부인공수정체의 안정성", 대한안과학회지, 51(6), pp.829~834 (2010), 대한안과학회
- Davison JA, "Capsular bag distension after endophacoemulsification and posterior chamber intraocular lens implantation", J Cataract Refract Surg, 16, pp.99~108 (1990)
- Nishi O, "Intraocular lens encapsulation by shrinkage of the capsulorhexis opening", J Cataract Refract Surg, 19, pp.544~545 (1993)
- Meacock WR, "Role of cytokines in the pathogenesis of posterior capsule opacification", Br J Ophthalmol, 84, pp.332~336 (2000)
- Wormstone IM., "Posterior capsule opacification: a cell biological perspective", Exp Eye Res, 74, pp.337~347 (2002)
- Kato S, "Anterior capsular contraction after cataract surgery in eyes of diabetic patients", Br J Ophthalmol, 85, pp.21~23 (2001)
- Spalton DJ., "Posterior capsular opacification after cataract surgery", Eye, 13(3), pp.489~492 (1999)
- Weiblinger RP, "Review of the clinical literature on the use of the Nd:YAG laser for posterior capsulotomy", J Cataract Refract Surg, 12, pp.162~170 (1986)
- Akerele T, "Posterior dislocation of Staar plate haptic silicone lenses following Nd:YAG capsulotomy", Eye, 13(5), pp.700~702 (1999)
- Michaeli-Cohen A, "Prevention of posterior capsule opacification with the CO2 laser", Ophthalmic Surg Lasers, 29, pp.985~990 (1998)
- Hayashi K, "Reduction in the area of the anterior capsule opening after polymethylmethacrylate, silicone, and soft acrylic intraocular lens implantation", Am J Ophthalmol, 123, pp.441~447 (1997)
- Hayashi K, "Intraocular lens factors that may affect anterior capsule contraction", Ophthalmology, 112, pp.286~292 (2005)
- Oshika T, "Adhesion of lens capsule to intraocular lenses of polymethylmethacrylate, silicone, and acrylic foldable materials: an experimental study", Br J Ophthalmol, 82, pp.549~553 (1998)
- Nagata T, "Adhesiveness of AcrySof to a collagen film", J Cataract Refract Surg, 24, pp.367~370 (1998)
- Sickenberg M, "Change in capsulorhexis size with four foldable loop-haptic lenses over 6 months", J Cataract Refract Surg, 24, pp.925~930 (1998)
- Miyake K, "Correlation between intraocular lens hydrophilicity and anterior capsule opacification and aqueous flare", J Cataract Refract Surg, 22(1), pp.764~769 (1996)
- Tsinopoulos IT, "Comparison of anterior capsule contraction between hydrophobic and hydrophilic intraocular lens models", Graefes Arch Clin Exp Ophthalmol, 248, pp.1155~1158 (2010)
- Gallagher SP, "Risk factors for anterior capsule contraction syndrome with polypropylene or poly(methyl methacrylate) haptics", J Cataract Refract Surg, 25, pp.1356~1361 (1999)
- Hayashi K, "Comparison of the stability of 1-piece and 3-piece acrylic intraocular lenses in the lens capsule", J Cataract Refract Surg, 31, pp.337~342 (2005)
- Park TK, "Changes in the area of the anterior capsule opening after intraocular lens implantation", J Cataract Refract Surg, 28, pp.1613~1617 (2002)
- Mingels A, "Comparison of two acrylic intraocular lenses with different haptic designs in patients with combined phacoemulsification and pars plana vitrectomy", Eye, 21, pp.1379~1383 (2007)
