Purpose: To evaluate changes over time of the anterior capsule opening size after phacoemulsification, based on haptic number and composition of three acrylic intraocular lenses (IOLs). Methods: Fifty-five patients (70 eyes) were included. All underwent phacoemulsification followed by implantation of either an acrylic IOL with two-haptic (one-piece, 26 eyes; three-piece, 22 eyes), or four-haptic (one-piece, 22 eyes). The area of the anterior capsule opening size was measured one week postoperatively (baseline) and at three months. Results: There was a significant reduction in the area of the anterior capsule opening from one week as compared to three months postoperatively in all groups (p < 0.001). However, there was no significant difference in the reduction in the anterior capsule opening between the IOLs (p = 0.36). Conclusions: The number and material of the haptic of the three acrylic IOLs did not influence the degree of anterior capsule opening shrinkage.

Abstract

Purpose: To evaluate changes over time of the anterior capsule opening size after phacoemulsification, based on haptic number and composition of three acrylic intraocular lenses (IOLs). Methods: Fifty-five patients (70 eyes) were included. All underwent phacoemulsification followed by implantation of either an acrylic IOL with two-haptic (one-piece, 26 eyes; three-piece, 22 eyes), or four-haptic (one-piece, 22 eyes). The area of the anterior capsule opening size was measured one week postoperatively (baseline) and at three months. Results: There was a significant reduction in the area of the anterior capsule opening from one week as compared to three months postoperatively in all groups (p < 0.001). However, there was no significant difference in the reduction in the anterior capsule opening between the IOLs (p = 0.36). Conclusions: The number and material of the haptic of the three acrylic IOLs did not influence the degree of anterior capsule opening shrinkage.

참고문헌 (32)

  1. Hansen SO, "Progressive constriction of the anterior capsular opening following intact capsulorhexis", J Cataract Refract Surg, 19, pp.77~82 (1993)
  2. Davison JA, "Capsule contraction syndrome", J Cataract Refract Surg, 19, pp.582~589 (1993)
  3. Hayashi K, "Anterior capsule contraction and intraocular lens dislocation after implant surgery in eyes with retinitis pigmentosa", Ophthalmology, 105, pp.1239~1243 (1998)
  4. Hayashi H, "Anterior capsule contraction and intraocular lens dislocation in eyes with pseudoexfoliation syndrome", Br J Ophthalmol, 82, pp.1429~1432 (1998)
  5. Hayashi H, "Area reduction in the anterior capsule opening in eyes of diabetes mellitus patients", J Cataract Refract Surg, 24, pp.1105~1110 (1998)
  6. Ursell PG, "Anterior capsule stability in eyes with intraocular lenses made of poly(methyl methacrylate), silicone, and AcrySof", J Cataract Refract Surg, 23, pp.1532~1538 (1997)
  7. Gonvers M, "Change in capsulorhexis size after implantation of three types of intraocular lenses", J Cataract Refract Surg, 23, pp.231~238 (1997)
  8. Hayashi K, "Anterior capsule contraction and intraocular lens decentration and tilt after hydrogel lens implantation", Br J Ophthalmol, 85, pp.1294~1297 (2001)
  9. Hayashi K, "Effect of anterior capsule contraction on visual function after cataract surgery", J Cataract Refract Surg, 33, pp.1936~1940 (2007)
  10. Cochener B, "Capsule contraction after continuous curvilinear capsulorhexis: poly(methyl methacrylate) versus silicone intraocular lenses", J Cataract Refract Surg, 25, pp.1362~1369 (1999)
  11. Dahlhauser KF, "Anterior capsule contraction with foldable silicone intraocular lenses", J Cataract Refract Surg, 24, pp.1216~1219 (1998)
  12. 김재우, "유리체절제술과 백내장 동시수술에서 네지지부인공수정체의 안정성", 대한안과학회지, 51(6), pp.829~834 (2010), 대한안과학회
  13. Davison JA, "Capsular bag distension after endophacoemulsification and posterior chamber intraocular lens implantation", J Cataract Refract Surg, 16, pp.99~108 (1990)
  14. Nishi O, "Intraocular lens encapsulation by shrinkage of the capsulorhexis opening", J Cataract Refract Surg, 19, pp.544~545 (1993)
  15. Meacock WR, "Role of cytokines in the pathogenesis of posterior capsule opacification", Br J Ophthalmol, 84, pp.332~336 (2000)
  16. Wormstone IM., "Posterior capsule opacification: a cell biological perspective", Exp Eye Res, 74, pp.337~347 (2002)
  17. Kato S, "Anterior capsular contraction after cataract surgery in eyes of diabetic patients", Br J Ophthalmol, 85, pp.21~23 (2001)
  18. Spalton DJ., "Posterior capsular opacification after cataract surgery", Eye, 13(3), pp.489~492 (1999)
  19. Weiblinger RP, "Review of the clinical literature on the use of the Nd:YAG laser for posterior capsulotomy", J Cataract Refract Surg, 12, pp.162~170 (1986)
  20. Akerele T, "Posterior dislocation of Staar plate haptic silicone lenses following Nd:YAG capsulotomy", Eye, 13(5), pp.700~702 (1999)
  21. Michaeli-Cohen A, "Prevention of posterior capsule opacification with the CO2 laser", Ophthalmic Surg Lasers, 29, pp.985~990 (1998)
  22. Hayashi K, "Reduction in the area of the anterior capsule opening after polymethylmethacrylate, silicone, and soft acrylic intraocular lens implantation", Am J Ophthalmol, 123, pp.441~447 (1997)
  23. Hayashi K, "Intraocular lens factors that may affect anterior capsule contraction", Ophthalmology, 112, pp.286~292 (2005)
  24. Oshika T, "Adhesion of lens capsule to intraocular lenses of polymethylmethacrylate, silicone, and acrylic foldable materials: an experimental study", Br J Ophthalmol, 82, pp.549~553 (1998)
  25. Nagata T, "Adhesiveness of AcrySof to a collagen film", J Cataract Refract Surg, 24, pp.367~370 (1998)
  26. Sickenberg M, "Change in capsulorhexis size with four foldable loop-haptic lenses over 6 months", J Cataract Refract Surg, 24, pp.925~930 (1998)
  27. Miyake K, "Correlation between intraocular lens hydrophilicity and anterior capsule opacification and aqueous flare", J Cataract Refract Surg, 22(1), pp.764~769 (1996)
  28. Tsinopoulos IT, "Comparison of anterior capsule contraction between hydrophobic and hydrophilic intraocular lens models", Graefes Arch Clin Exp Ophthalmol, 248, pp.1155~1158 (2010)
  29. Gallagher SP, "Risk factors for anterior capsule contraction syndrome with polypropylene or poly(methyl methacrylate) haptics", J Cataract Refract Surg, 25, pp.1356~1361 (1999)
  30. Hayashi K, "Comparison of the stability of 1-piece and 3-piece acrylic intraocular lenses in the lens capsule", J Cataract Refract Surg, 31, pp.337~342 (2005)
  31. Park TK, "Changes in the area of the anterior capsule opening after intraocular lens implantation", J Cataract Refract Surg, 28, pp.1613~1617 (2002)
  32. Mingels A, "Comparison of two acrylic intraocular lenses with different haptic designs in patients with combined phacoemulsification and pars plana vitrectomy", Eye, 21, pp.1379~1383 (2007)

관련 논문AI추천