흉부 전・후방향 검사 시 고관전압 및 산란선 후처리 소프트웨어 적용이 화질과 선량에 미치는 영향

Effect of High Tube Voltage and Scatter Ray Post-processing Software on Image Quality and Radiation Dose During Chest Anteroposterior Radiography

1

조회

0

다운로드

4

인용

0

참고문헌

키워드

주제분류방사선과학

초록

This study aims to present new chest AP examination exposure conditions through a study on the effect on image quality and patient dose by applying high tube voltage and scatter ray post-processing software during chest AP examination in digital radiography equipment. This study was used a human body phantom and in the chest AP position, the dosimeter was placed horizontally at the thoracic spine 6. The experiment was conducted by dividing into a low tube voltage (70 kVp, 400 ㎃, 3.2 ㎃s) group and a high tube voltage (100 kVp, 400 ㎃, 1.2 ㎃s) group. The collimation size (14″× 17″) and the source to image receptor distance(110 cm) were same applied to both groups. Radiation dose was presented to dose area product and entrance surface dose. Image quality was compared and analyzed by comparing the difference between the signal-to-noise ratio and the contrast-to-noise ratio of the image according to the application of the scatter ray post-processing software under each condition. The average value of the entrance surface dose in the low and high tube voltage conditions was 93.04±0.45 μ㏉ and 94.25±1.51 μ㏉, which was slightly higher in the high tube voltage condition, but the dose area product was 0.97±0.04 μ㏉ and 0.93±0.01 μ㏉. There was a statistically significant difference in the group mean value(p<0.01). In terms of image quality, the values of the signal-to-noise ratio and the contrast noise ratio were higher in the high tube voltage than in the low tube voltage, and decreased when the scattering line post-processing function was used, but the contrast resolution was improved. If there is a scatter ray post-processing function during chest AP examination, it is helpful to actively utilize it to improve the image quality. However, when this function is not available, I thought that applying a higher tube voltage state than a low tube voltage state will help to realize images with a large amount of information without changing the dose.

Abstract

This study aims to present new chest AP examination exposure conditions through a study on the effect on image quality and patient dose by applying high tube voltage and scatter ray post-processing software during chest AP examination in digital radiography equipment. This study was used a human body phantom and in the chest AP position, the dosimeter was placed horizontally at the thoracic spine 6. The experiment was conducted by dividing into a low tube voltage (70 kVp, 400 ㎃, 3.2 ㎃s) group and a high tube voltage (100 kVp, 400 ㎃, 1.2 ㎃s) group. The collimation size (14″× 17″) and the source to image receptor distance(110 cm) were same applied to both groups. Radiation dose was presented to dose area product and entrance surface dose. Image quality was compared and analyzed by comparing the difference between the signal-to-noise ratio and the contrast-to-noise ratio of the image according to the application of the scatter ray post-processing software under each condition. The average value of the entrance surface dose in the low and high tube voltage conditions was 93.04±0.45 μ㏉ and 94.25±1.51 μ㏉, which was slightly higher in the high tube voltage condition, but the dose area product was 0.97±0.04 μ㏉ and 0.93±0.01 μ㏉. There was a statistically significant difference in the group mean value(p<0.01). In terms of image quality, the values of the signal-to-noise ratio and the contrast noise ratio were higher in the high tube voltage than in the low tube voltage, and decreased when the scattering line post-processing function was used, but the contrast resolution was improved. If there is a scatter ray post-processing function during chest AP examination, it is helpful to actively utilize it to improve the image quality. However, when this function is not available, I thought that applying a higher tube voltage state than a low tube voltage state will help to realize images with a large amount of information without changing the dose.

참고문헌 (15)

  1. 이상호, "Sprague Dawley Rat의 미세병변에서 Moire Artifact를 제거하기 위한 Grid suppression software 사용 후 영상분석", 방사선기술과학, 40(4), pp.575~580 (2017), 대한방사선과학회[DOI]
  2. Kingo C, "Chest X-ray diagnosis ABC", 51~58 (2011)
  3. 주영철, "흉부 방사선검사 영상을 이용한 한국인 정상 여성의 임신기와 비 임신기 심장크기와 심흉비 비교", 방사선기술과학, 41(3), pp.223~229 (2018), 대한방사선과학회[DOI]
  4. 주영철, "한국인 성인 남성의 흉부 방사선영상에서 자세와 연령에 따른 심장 크기 및 심흉비의 정상 범위와 변환율", 방사선기술과학, 40(2), pp.179~186 (2017), 대한방사선과학회[DOI]
  5. 이진수, "Mobile Chest AP 검사 시 환자자세와 입사각도에 따른 Levin-tube tip의 영상왜곡 분석", 한국방사선학회논문지, 9(7), pp.467~471 (2015), 한국방사선학회[DOI]
  6. 주영철, "한국인 임산부의 흉부 후-전 방향 방사선검사 시 적절한 차폐막 높이", 방사선기술과학, 41(2), pp.97~102 (2018), 대한방사선과학회[DOI]
  7. 이현우, "흉부 방사선영상의 좌, 우 반전 발생 여부 컨벌루션 신경망 기반 정확도 평가", 방사선기술과학, 43(2), pp.65~70 (2020), 대한방사선과학회
  8. Huh J, "Visual evaluation of rib shadow and lung marking during high-voltage chest radiography", Journal of Korean Society of Radiological Technology, 15(1), pp.99~105 (1992)
  9. 박한솔, "디지털 흉부 방사선 검사의 화질과 선량의 최적화에 관한 연구", 한국방사선학회논문지, 11(1), pp.55~61 (2017), 한국방사선학회[DOI]
  10. Park GM, "Evaluation and comparison of signal to noise using image post-processing technique of portable X-ray device", Journal of The Korean Society of Radiologycal Imaging Technology, (1), pp.81~88 (2019)
  11. Wi DH, "The study on the usefulness of bone suppression function in the chest PA", Journal of The Korean Society of Radiologycal Imaging Technology, pp.65~74 (2017)
  12. 박지군, "디지털 방사선 촬영장치의 흉부촬영 최적 조사조건에 관한 연구", 한국방사선학회논문지, 10(2), pp.109~115 (2016), 한국방사선학회[DOI]
  13. Suzuck K, "Image-processing technique for suppressing ribs in chest radiographs by means of massive training artificial neural network(MATNN)", IEEE Trans Med Imaging, 25, pp.406~416 (2006)
  14. Chen S, "Enhancement of chest radiographs obtained in the intensive care unit through bone suppression and consistent processing", Phys Med Biol, 61(6), pp.2283~2301 (2016)
  15. MFDS, "Guidelines for patient dose recommendations in the abdomen, pelvis and lumbar radiography. Radiation Safety Management Series. 2012;25:11-1470000–002660-01", ~ (2012)

관련 논문AI추천

이 간행물의 다른 논문 (13건)