본문 바로가기
KERD
논문KCI 등재

다발성 경화증 질환의 자기공명 T2 강조영상에서 단면 두께 변화에 따른 잡음 평가

Noise Level Evaluation According to Slice Thickness Change in Magnetic Resonance T2 Weighted Image of Multiple Sclerosis Disease

0

조회

0

다운로드

1

인용

0

참고문헌

키워드

주제분류방사선과학

초록

Magnetic resonance imaging(MRI) uses strong magnetic field to image the cross-section of human body and has excellent image quality with no risk of radiation exposure. Because of above-mentioned advantages, MRI has been widely used in clinical fields. However, the noise generated in MRI degrades the quality of medical images and has a negative effect on quick and accurate diagnosis. In particular, examining a object with a detailed structure such as brain, image quality degradation becomes a problem for diagnosis. Therefore, in this study, we acquired T2 weighted 3D data of multiple sclerosis disease using BrainWeb simulation program, and used quantitative evaluation factors to find appropriate slice thickness among 1, 3, 5, and 7 mm. Coefficient of variation and contrast to noise ratio were calculated to evaluate the noise level, and root mean square error and peak signal to noise ratio were used to evaluate the similarity with the reference image. As a result, the noise level decreased as the slice thickness increased, while the similarity decreased after 5 mm. In conclusion, as the slice thickness increases, the noise is reduced and the image quality is improved. However, since the edge signal is lost due to overlapped signal, it is considered that selecting appropriate slice thickness is necessary.

Abstract

Magnetic resonance imaging(MRI) uses strong magnetic field to image the cross-section of human body and has excellent image quality with no risk of radiation exposure. Because of above-mentioned advantages, MRI has been widely used in clinical fields. However, the noise generated in MRI degrades the quality of medical images and has a negative effect on quick and accurate diagnosis. In particular, examining a object with a detailed structure such as brain, image quality degradation becomes a problem for diagnosis. Therefore, in this study, we acquired T2 weighted 3D data of multiple sclerosis disease using BrainWeb simulation program, and used quantitative evaluation factors to find appropriate slice thickness among 1, 3, 5, and 7 mm. Coefficient of variation and contrast to noise ratio were calculated to evaluate the noise level, and root mean square error and peak signal to noise ratio were used to evaluate the similarity with the reference image. As a result, the noise level decreased as the slice thickness increased, while the similarity decreased after 5 mm. In conclusion, as the slice thickness increases, the noise is reduced and the image quality is improved. However, since the edge signal is lost due to overlapped signal, it is considered that selecting appropriate slice thickness is necessary.

참고문헌 (31)

  1. Zhou J, "Using the amide proton signals of intracellular proteins and peptides to detect pH effects in MRI", Nature Medicine, 9(8), pp.1085~1090 (2003)
  2. Sharma A, "Missing MRI pulse sequence synthesis using multi-modal generative adversarial network", IEEE Transactions on Medical Imaging, 39(4), pp.1170~1183 (2019)
  3. Antoch G, "Combined PET", MRI: A new dimension in whole-body oncology imaging?, 2009, pp.36(1), 113~120
  4. 민정환, "3.0T 자기공명영상을 이용한 해상력 특성에 대한 연구", 방사선기술과학, 43(4), pp.251~257 (2020), 대한방사선과학회
  5. Macovski A, "Noise in MRI", Magnetic Resonance in Medicine, 36(3), pp.494~497 (1996)
  6. 김형균, "자기공명영상에서 정형보철 금속이 신호강도와 영상왜곡에 미치는 영향", 방사선기술과학, 35(4), pp.321~326 (2012), 대한방사선과학회
  7. Honal M, "Compensation of breathing motion artifacts for MRI with continuously moving table", Magnetic Resonance in Medicine, 63(3), pp.701~712 (2010)
  8. Savio SJ, "Effect of slice thickness on brain magnetic resonance image texture analysis", Biomedical Engineering Online, 9(1), pp.1~14 (2010)
  9. Smith TB, "MRI artifacts and correction strategies", Imaging in Medicine, 2(4), pp.445~ (2010)
  10. Butts K, "Reduction of blurring in view angle tilting MRI", Magnetic Resonance in Medicine: An Official Journal of the International Society for Magnetic Resonance in Medicine, 53(2), pp.418~424 (2005)
  11. Mahmoudzadeh AP, "Interpoltation-based super-resolution reconstruction: Effects of slice thickness", Journal of Medical Imaging, 1(3), pp.034007~ (2014)
  12. Schmierer K, "Diffusion tensor imaging of post mortem multiple sclerosis brain", Neuroimage, 35(2), pp.467~477 (2007)
  13. Turner B, "Cerebral atrophy and disability in relapsing-remitting and secondary progressive multiple sclerosis over four years", Multiple Sclerosis Journal, 9(1), pp.21~27 (2003)
  14. Cocosco CA, "Brainweb: Online interface to a 3D MRI simulated brain database", NeuroImage, 5(4) (1997)
  15. Collins DL, "Design and construction of a realistic digital brain phantom", IEEE Transactions on Medical Imaging, 17(3), pp.463~468 (1998)
  16. 김남영, "자기공명영상장치의 뇌 T2 강조 영상에서 여기횟수 변화에 따른 영상 특성의 경향성 평가: MRiLab Simulation 연구", 한국방사선학회논문지, 15(1), pp.9~14 (2021), 한국방사선학회[DOI]
  17. Sudeep PV, "Nonlocal linear minimum mean square error methods for denoising MRI", Biomedical Signal Processing and Control, 20, pp.125~134 (2015)
  18. Isa IS, "Evaluating denoising performances of fundamental filters for T2-weighted MRI images", Procedia Computer Science, 60, pp.760~768 (2015)
  19. Kwan RKS, "MRI simulation-based evaluation of image-processing and classification methods", IEEE Transactions on Medical Imaging, 18(11), pp.1085~1097 (1999)
  20. Kwan RKS, "An extensible MRI simulator for post-processing evaluation, in Visualization in Biomedical Computing", Lecture Notes in Computer Science, 1131, pp.135~140 (1996)
  21. Gopalan K, "Quantitative anatomy mimicking slice phantoms", Magnetic Resonance in Medicine, 86(2), pp.1159~1166 (2021)
  22. He Y, "Dynamic PET image denoising with deep learning-based joint filtering", IEEE Access, 9, pp.41998~42012 (2021)
  23. Kasiri K, "Comparison evaluation of three brain MRI segmentation methods in software tools", 201017th Iranian Conference of Biomedical Engineering (ICBME), pp.1~4 (2010)
  24. Nakamura K, "Segmentation of brain magnetic resonance images for measurements of gray matter atrophy in multiple sclerosis patients", NeuroImage, 44(3), pp.769~776 (2009)
  25. Dolezal O, "Detection of cortical lesions is dependent on choice of slice thickness in patients with multiple sclerosis", International Review of Neurobiology, 79, pp.475~489 (2007)
  26. Rousseau F, "An a contrario approcah for change detection in 3D multimodal images:Application to multiple sclerosis in MRI", 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, pp.2069~2072 (2007)
  27. 이선엽, "A Study on a Method to Reduce the Effect of the Cross-talk Artifact in a Simultaneous, Multiple-slice, Plane, Oblique MRI Scan", Journal of the Korean Physical Society, 61(5), pp.807~814 (2012), 한국물리학회
  28. Lee YJ, "MR imaging with LAIR pulse sequence in various cerebral lesions : comparison with T2-weighted imaging", Journal of Korean Radiological Society, 38, pp.397~401 (1998)
  29. Absinta M, "Identification of chronic active multiple sclerosis lesions on 3T MRI", American Journal of Neuroradiology, 39(7), pp.1233~1238 (2018)
  30. Wang KY, "Comparing lesion detection of infratentorial multiple sclerosis lesions between T2-weighted spin-echo, 2D-FLAIR, and 3D-FLAIR sequences", Clinical Imaging, 51, pp.229~234 (2018)
  31. Gabr RE, "Sensitive detection of infratentorial and upper cervical cord lesions in multiple sclerosis with combined 3D FLAIR and T2-weighted (FLAIR3)imaging", American Journal of Neuroradiology, 41(11), pp.2062~2067 (2020)

관련 논문AI추천

이 간행물의 다른 논문 (13건)