3.0T 자기공명영상을 이용한 잡음전력스펙트럼 특성 평가

Evaluation of Noise Power Spectrum Characteristics by Using Magnetic Resonance Imaging 3.0T

0

조회

0

다운로드

5

인용

0

참고문헌

키워드

주제분류방사선과학

초록

This study aim of quantitative assessment of Noise Power Spectrum(NPS) and image characteristics of by acquired the optimal image for noise characteristics and quality assurance by using magnetic resonance imaging(MRI). MRI device was (MAGNETOM Vida 3.0T MRI; Siemense healthcare system; Germany) used and the head/neck shim MR receive coil were 20 channels coil and a diameter 200 mm hemisphere phantom. Frequency signal could be acquired the K-space trajectory image and white image for NPS. The T2 image highest quantitatively value for NPS finding of showed the best value of 0.026 based on the T2 frequency of 1.0 mm-1. The NPS acquired of showed that the T1 CE turbo image was 0.077, the T1 CE Conca2 turbo image was 0.056, T1 turbo image was 0.061, and the T1 Conca2 turbo image was 0.066. The assessment of NPS image characteristics of this study were to that could be used efficiently of the MRI and to present the quantitative evaluation methods and image noise characteristics of 3.0T MRI.

Abstract

This study aim of quantitative assessment of Noise Power Spectrum(NPS) and image characteristics of by acquired the optimal image for noise characteristics and quality assurance by using magnetic resonance imaging(MRI). MRI device was (MAGNETOM Vida 3.0T MRI; Siemense healthcare system; Germany) used and the head/neck shim MR receive coil were 20 channels coil and a diameter 200 mm hemisphere phantom. Frequency signal could be acquired the K-space trajectory image and white image for NPS. The T2 image highest quantitatively value for NPS finding of showed the best value of 0.026 based on the T2 frequency of 1.0 mm-1. The NPS acquired of showed that the T1 CE turbo image was 0.077, the T1 CE Conca2 turbo image was 0.056, T1 turbo image was 0.061, and the T1 Conca2 turbo image was 0.066. The assessment of NPS image characteristics of this study were to that could be used efficiently of the MRI and to present the quantitative evaluation methods and image noise characteristics of 3.0T MRI.

참고문헌 (17)

  1. 민정환, "1.5T 자기공명영상을 이용한 물리적 영상 특성에 대한 연구", 방사선기술과학, 42(5), pp.329~334 (2019), 대한방사선과학회[DOI]
  2. Miyati T, "Measurements of MTF and SNR(f)using a subtraction method im MRI", Physics in Medicine and Biology, 47, pp.2961~2972 (2002)
  3. Steckner MC, "Computing the modulation transfer function of a magnetic resonance imager", Med. Phys, 21, pp.483~489 (1994)
  4. Mohapatra SM, "Transfer function measurement and analysis for magnetic resonance imager", Med. Phys, 18(6), pp.1141~1144 (1991)
  5. 민정환, "3.0T 자기공명영상을 이용한 해상력 특성에 대한 연구", 방사선기술과학, 43(4), pp.251~257 (2020), 대한방사선과학회
  6. 민정환, "간접평판형 검출기에서 국제전자기술위원회 기준을 통한 잡음전력스펙트럼 비교 연구", 방사선기술과학, 41(5), pp.457~462 (2018), 대한방사선과학회[DOI]
  7. 정회원, "다양한 디지털 방사선 시스템의 물리적 영상 특성 조사", 방사선기술과학, 40(3), pp.363~370 (2017), 대한방사선과학회[DOI]
  8. 정회원, "CsI(TI) Indirect Flat Panel Detector의 선질에 따른 물리적 영상 평가", 방사선기술과학, 35(2), pp.109~117 (2012), 대한방사선과학회[DOI]
  9. 손순룡, "Evaluation of Image Quality for Various Electronic Portal Imaging Devices in Radiation Therapy", 방사선기술과학, 38(4), pp.451~461 (2015), 대한방사선과학회[DOI]
  10. Hahm HK, "The study on the subject development of MRI image quality evaluation", Department of Radiology, pp.2008
  11. 민정환, "간접평판형 검출기에서 변조전달함수 측정 시 Edge 각도에 따른 비교 연구", 방사선기술과학, 42(4), pp.259~263 (2019), 대한방사선과학회
  12. 손순룡, "Measurement of Image Quality According to the Time of Computed Radiography System", 방사선기술과학, 38(4), pp.365~374 (2015), 대한방사선과학회[DOI]
  13. 김기원, "유방영상에서 엣지를 이용한 물리적 영상 평가", 방사선기술과학, 39(3), pp.415~420 (2016), 대한방사선과학회[DOI]
  14. 김기원, "컴퓨터단층검사에서 AAPM Phantom을 이용한 변조전달함수 평가", 방사선기술과학, 39(2), pp.193~198 (2016), 대한방사선과학회[DOI]
  15. Fujita H, "A simple method for determining the modulation transfer function in digital radiography", IEEE Trans Med Imaging, 11(1), pp.34~39 (1992)
  16. Samei E, "A method for measuring the presampled MTF of digital radiographic systems using an edge test device", Medical Physics, 25, pp.102~ (1998)
  17. Greer PB, "Evaluation of an algorithm for the assessment of the MTF using an edge method", Medical Physics, 27, pp.2048~ (2000)

관련 논문AI추천

이 간행물의 다른 논문 (7건)