본문 바로가기
KERD
논문KCI 등재

뇌 확산강조 자기공명영상에 대한 정량적, 성적 평가: 1.5 T와 3.0 T 기기 비교

Quantitative and Qualitative Evaluation of Brain Diffusion Weighted Magnetic Resonance Imaging: Comparision with 1.5 T and 3.0 T Units

2

조회

0

다운로드

2

인용

0

참고문헌

키워드

초록

DWI of biological effects are independent of magnetic field strength in various regions. High field strength, however, does affect the signal to noise ratio (SNR) and artifacts of diffusion weighted imaging (DWI) images, which ultimately will influence the quantitative of diffusion imaging . In this study, the effects of field strength on DWI are reviewed. The effects of the diseases also are discussed. Comparing DWI in cerebellum, WM, GM, Hyperacute region measurements both as a function of field strength (1.5 T and 3.0 T). Overall, the SNR of the DWI roughly doubled going from 1.5 T to 3.0 T. In summary, DWI studies at 3.0 T is provided significantly improved DWI measurements relative to studies at 1.5 T.

Abstract

DWI of biological effects are independent of magnetic field strength in various regions. High field strength, however, does affect the signal to noise ratio (SNR) and artifacts of diffusion weighted imaging (DWI) images, which ultimately will influence the quantitative of diffusion imaging . In this study, the effects of field strength on DWI are reviewed. The effects of the diseases also are discussed. Comparing DWI in cerebellum, WM, GM, Hyperacute region measurements both as a function of field strength (1.5 T and 3.0 T). Overall, the SNR of the DWI roughly doubled going from 1.5 T to 3.0 T. In summary, DWI studies at 3.0 T is provided significantly improved DWI measurements relative to studies at 1.5 T.

참고문헌 (10)

  1. de Baere T, "Osteosarcoma after chemotherapy : evaluation with contrast material-enhanced subtraction MR imaging", Radiology, 185(2), pp.587~592 (1992)
  2. Goelman G, "Chemical-shift artifact reduction in hadamard-encoded MR spectroscopic imaging at high (3T and 7T) magnetic fields", Magn. Reson. Med, 58(1), pp.167~173 (2007)
  3. Hacke W, "Intravenous desmoteplase in patients with acute ischaemic stroke selected by MRI perfusion-diffusion weighted imaging or perfusion CT (DIAS-2): a prospective, randomised, double-blind, placebo-controlled study", Lancet Neurol, 8(2), pp.141~150 (2009)
  4. Jung JY, "Knee derangements : comparison of isotropic 3D fast spin-echo, isotropic 3D balanced fast field-echo, and conventional 2D fast spin-echo MR imaging", Radiology, 268(3), pp.802~813 (2013)
  5. Matsui JT, "Diffusion weighted imaging of prefrontal cortex in prodromal Huntington’s disease", Human Brain Mapp, 35(4), pp.1562~1573 (2013)
  6. Nghiem HV, "The pelvis : T2-weighted fast spin-echo MRimaging", Radiology, 185(1), pp.213~217 (1992)
  7. Reeder SB, "Iterativedecomposition of water and fat with echoasymmetry and leastsquaresestimation (IDEAL): application with fast spin-echoimaging", Magn. Reson. Med, 54(3), pp.636~644 (2005)
  8. Sakamoto Y, "Early ischaemic diffusion lesion reduction in patients treated with intravenous tissue plasminogen activator : infrequent, but significantly associated with recanalization. Int. J", Stroke, 8(5), pp.321~326 (2013)
  9. Schmitz BL, "Advantages and pitfalls in 3T MR brain imaging: a pictorial review", Am. J. Neuroradiol, 26(9), pp.2229~2239 (2005)
  10. Shmueli K, "Magnetic susceptibility mapping of brain tissue in vivo using MRI phase data", Magn. Reson. Med, 62(6), pp.1510~1522 (2009)

관련 논문AI추천

이 간행물의 다른 논문 (12건)