This study uses the 'S-align' function to present a reference value of the X-ray tube angle for the realization of an image similar to that of the chest PA image during chest AP radiography. This study targeted dummy phantom and used a 17"×17" DR image receptor. The irradiation conditions were 110 ㎸p, 160 ㎃, 50 ㎳, and the distance between the central X-ray and the image receptor was set to 180 ㎝ and 110 ㎝, respectively. The end of the catheter was placed at the 11th thoracic height to indicate the nasogastric tube. In the case of lung apex length measurement, the mean value of measurement was 30.53±0.47 in PA. T 0°, TCA 5∼25°, TCE 5∼15° were 21.07±0.29, 27.60±0.21, 34.13±0.44, 39.86±0.31, 45.96±0.61 ㎜, 54.13±0.37 ㎜, 16.16±0.46 ㎜, 9.81±0.35 ㎜, 2.75±0.30 ㎜, respectively. For the depth of the catheter end, the average value measured at PA was 6.70±0.31 ㎜. T 0°, TCA 5∼25°, TCE 5∼15° were 15.72±0.38 ㎜, 24.10±0.50 ㎜, 29.24±0.86 ㎜, 34.35±0.35 ㎜, 41.06±1.08 ㎜, 48.07±0.38 ㎜, 12.85±0.25 ㎜, 7.92±0.36 ㎜, 3.01±0.39 ㎜, respectively. The length of the lung apex was similar to that of chest PA when the angle of incidence was adjusted from 5° to 10° in the leg direction, and the depth of the catheter tip was most similar when the X-ray tube angle was incident at 10° in the head direction. Therefore, To change the X-ray tube angle according to the purpose of the examination during the chest AP radiography using ‘S-align’ function is considered necessary.

Abstract

This study uses the 'S-align' function to present a reference value of the X-ray tube angle for the realization of an image similar to that of the chest PA image during chest AP radiography. This study targeted dummy phantom and used a 17"×17" DR image receptor. The irradiation conditions were 110 ㎸p, 160 ㎃, 50 ㎳, and the distance between the central X-ray and the image receptor was set to 180 ㎝ and 110 ㎝, respectively. The end of the catheter was placed at the 11th thoracic height to indicate the nasogastric tube. In the case of lung apex length measurement, the mean value of measurement was 30.53±0.47 in PA. T 0°, TCA 5∼25°, TCE 5∼15° were 21.07±0.29, 27.60±0.21, 34.13±0.44, 39.86±0.31, 45.96±0.61 ㎜, 54.13±0.37 ㎜, 16.16±0.46 ㎜, 9.81±0.35 ㎜, 2.75±0.30 ㎜, respectively. For the depth of the catheter end, the average value measured at PA was 6.70±0.31 ㎜. T 0°, TCA 5∼25°, TCE 5∼15° were 15.72±0.38 ㎜, 24.10±0.50 ㎜, 29.24±0.86 ㎜, 34.35±0.35 ㎜, 41.06±1.08 ㎜, 48.07±0.38 ㎜, 12.85±0.25 ㎜, 7.92±0.36 ㎜, 3.01±0.39 ㎜, respectively. The length of the lung apex was similar to that of chest PA when the angle of incidence was adjusted from 5° to 10° in the leg direction, and the depth of the catheter tip was most similar when the X-ray tube angle was incident at 10° in the head direction. Therefore, To change the X-ray tube angle according to the purpose of the examination during the chest AP radiography using ‘S-align’ function is considered necessary.

참고문헌 (18)

  1. Momoshima S, "Imaging Medicine (Diagnosis), Korea, Commission for the Compilation of Radiomedical Diagnosis" (2018), Book Publishing Medicine Education
  2. KDCA, "Assessment of Radiation Exposure of Korean Population by medical radiation", ~ (2021)
  3. CKPub, "TEXTBOOK of Radiographic positioning and Clinical Diagnosis vol. 2" (2008), Medical Imaging Technology Research Association
  4. Joo YC, "Consideration of Patient Position on Posteroanterior Chest Projection", The Korea Contents Association 2015 A Collection of Papers from the Spring Conference, pp.161~162 (2015)
  5. Joo YC, "Analysis of Normal Range of Heart Size and Cardiothoracic Ratio", pp.2016
  6. 주영철, "한국인 성인 남성의 흉부 방사선영상에서 자세와 연령에 따른 심장 크기 및 심흉비의 정상 범위와 변환율", 방사선기술과학, 40(2), pp.179~186 (2017), 대한방사선과학회[DOI]
  7. Bae JI, "Insertion and Management of Central Venous Catheters", Hanyang Medical Review, 31(1) (2011)
  8. 김재석, "중심정맥카테터 삽입의 이상위치로 발생한 편측성 흉수 1례", Tuberculosis and Respiratory Diseases, 60(6), pp.690~693 (2006), 대한결핵및호흡기학회
  9. Seo EH, "Statistical significance of complication according to the Central Venous Catheter Tip position", Journal of Korean Society of Cardio-Vascular Interventional Technology, 13(1), pp.133~143 (2010)
  10. "KMCRIC" (2020)[URL]
  11. 이진수, "Mobile Chest AP 검사 시 환자자세와 입사각도에 따른 Levin-tube tip의 영상왜곡 분석", 한국방사선학회논문지, 9(7), pp.467~471 (2015), 한국방사선학회[DOI]
  12. 최규락, "흉부 측와위 촬영 시 전후방향과 후전방향 검사의 유용성 비교", 한국방사선학회논문지, 7(3), pp.232~238 (2013), 한국방사선학회[DOI]
  13. 주영철, "디지털방사선 환경에서 흉부 후 - 전 방향 검사 시 초점과 영상수용체간 거리의 적절성", 방사선기술과학, 39(2), pp.135~142 (2016), 대한방사선과학회[DOI]
  14. 박여진, "디지털 흉부 후·전 방향 방사선영상을 이용한 정상 한국인 폐 크기의 영상의학적 계측", 방사선기술과학, 41(1), pp.1~6 (2018), 대한방사선과학회[DOI]
  15. 박지군, "디지털 방사선 촬영장치의 흉부촬영 최적 조사조건에 관한 연구", 한국방사선학회논문지, 10(2), pp.109~115 (2016), 한국방사선학회[DOI]
  16. 이인자, "흉부 디지털 방사선 촬영 시 C-D phantom을 이용한 촬영조건에 따른 영상 평가", 방사선기술과학, 32(1), pp.25~32 (2009), 대한방사선과학회
  17. 김민석, "새로운 발 사방향 검사법의 유용성에 관한 연구", 방사선기술과학, 44(5), pp.443~449 (2021), 대한방사선과학회
  18. Choi JH, "Analog Radiographic imaging" (2013), Shinkwangpub

관련 논문AI추천

이 간행물의 다른 논문 (7건)