복부 방사선검사 자세가 유방선량에 미치는 영향

Effects of Breast Dose on Plain Abdominal Position

2

조회

0

다운로드

1

인용

0

참고문헌

키워드

주제분류방사선과학

초록

The purpose of this study is to investigate the effect of posture changes(Anteroposterior projection, Posteroanterior projection) in the plain abdominal examination on breast dose and to examine its clinical usefulness. This study was used a human body phantom and a glass dosimeter. Glass dosimeters were directly inserted from the center and outside of medial and lateral. In this study, the deep dose was measured in the right breast and the surface dose in the left breast. During the abdominal examination, the central X-ray incident point was perpendicularly incident to the image receptor 5 cm above the iliac crest. The exposure parameters were 82 ㎸p, 320 ㎃, 50 ㎳, x-ray field size 14×17 inch The distance between the center X-ray and the detector was fixed at 110 cm, and only the top two AEC chambers were used. As a result of this study, the medial and lateral side doses of the right breast were 535.73±30.68 μ㏉ and 414.46±33.52 μ㏉ for erect AP, and 145.80±18.52 μ㏉ and 148.76±12.92 μ㏉ in erect PA. The superficial breast dose was 754.00±68.36 μ㏉ on the medial side and 674.06±45.58 μ㏉ on the lateral side in the erect AP, 70.66±7.98 μ㏉ on the medial side, and 86.46±15.35 μ㏉ on the lateral side in the erect PA. There was a statistically significant difference in the difference between the mean values of the medial and lateral side doses in the deep and superficial areas of the breast according to the postural change (p <0.01). As a result of this study, If the abdominal radiography was examined in the PA position, the dose reduction effect was 72.78% on the medial side, 64.10% on the lateral side of the deep breast, 90.62% on the medial side, and 87.17% on the lateral side of the superficial breast compared to the AP position.

Abstract

The purpose of this study is to investigate the effect of posture changes(Anteroposterior projection, Posteroanterior projection) in the plain abdominal examination on breast dose and to examine its clinical usefulness. This study was used a human body phantom and a glass dosimeter. Glass dosimeters were directly inserted from the center and outside of medial and lateral. In this study, the deep dose was measured in the right breast and the surface dose in the left breast. During the abdominal examination, the central X-ray incident point was perpendicularly incident to the image receptor 5 cm above the iliac crest. The exposure parameters were 82 ㎸p, 320 ㎃, 50 ㎳, x-ray field size 14×17 inch The distance between the center X-ray and the detector was fixed at 110 cm, and only the top two AEC chambers were used. As a result of this study, the medial and lateral side doses of the right breast were 535.73±30.68 μ㏉ and 414.46±33.52 μ㏉ for erect AP, and 145.80±18.52 μ㏉ and 148.76±12.92 μ㏉ in erect PA. The superficial breast dose was 754.00±68.36 μ㏉ on the medial side and 674.06±45.58 μ㏉ on the lateral side in the erect AP, 70.66±7.98 μ㏉ on the medial side, and 86.46±15.35 μ㏉ on the lateral side in the erect PA. There was a statistically significant difference in the difference between the mean values of the medial and lateral side doses in the deep and superficial areas of the breast according to the postural change (p <0.01). As a result of this study, If the abdominal radiography was examined in the PA position, the dose reduction effect was 72.78% on the medial side, 64.10% on the lateral side of the deep breast, 90.62% on the medial side, and 87.17% on the lateral side of the superficial breast compared to the AP position.

참고문헌 (16)

  1. Kahnzada TW, "Abuse of plain abdominal radiographs in abdominal pain", Rawal Med J, 32(1), pp.48~50 (2007)
  2. Kang BS, "Radiographic Imaging" (2014), Daihaks
  3. The Korean Society of Medical Imaging Technology, "TEXTBOOK of Radiographic Positioning and Clinical Diagnosis" (2019), Chung-Ku
  4. Feyler S, "Plain abdominal radiographs in acute medical emergencies : An abused investigation", Postgraduate Medical Journal, 78(916), pp.94~96 (2002)
  5. MFDS, "Guidelines for patient dose recommendations in the abdomen, pelvis and lumbar radiography. Radiation Safty Management Series, No.25, 11-1470000-002660-01", ~ (2012)
  6. UNSCEAR 2000 Report Vol. I Source and Effects of Ionization. Annex D Medical Radiation Exposure, , UNSECAR, ~ (2000)
  7. Metaxas VI, "Patient doses in common diagnostic X-ray examinations", Radiation Protection Dosimetry, 184(1), pp.12~27 (2019)
  8. Aliasgharzadeh A, "Measurement of entrance skin dose and calculation of effective dose for common diagnostic X-ray examinations in Kashan, Iran", Global Journal of Health Science, 7(5), pp.202~ (2015)
  9. Hawking N, "Effects of AEC chamber selection on patient dose and image quality", Radiologic Technology, 80(5), pp.411~419 (2009)
  10. 구노현, "자동노출제어를 이용한 복부 일반 X선 검사에서 체질량지수가 입사표면공기커마에 미치는 영향", 한국방사선학회논문지, 12(5), pp.659~667 (2018), 한국방사선학회[DOI]
  11. 조지환, "유방촬영검사에서 선량지표분석에 대한 모니터링", 한국방사선학회논문지, 10(7), pp.477~482 (2016), 한국방사선학회[DOI]
  12. 곽영곤, "전산화 단층검사 시 Bismuth와 CARE kV System을 이용한 선량 저감화에 대한 연구", 한국콘텐츠학회 논문지, 14(8), pp.233~242 (2014), 한국콘텐츠학회[DOI]
  13. Padovani R, "Patient doses and risks from diagnostic radiology in North-east Italy", The British Journal of Radiology, 60(710), pp.155~165 (1987)
  14. an Ghearr FAN, "The PA projection of the abdomen : A dose reducing technique", Radiography, 4(3), pp.195~203 (1998)
  15. Marshall N, "A comparison of radiation dose in examination of the abdomen using different radiological imaging techniques", The British Journal of Radiology, 67(797), pp.478~484 (1994)
  16. 진계환, "청소년기 여성의 척추측만증 검사에서 유방입사선량 저감효과", 한국방사선학회논문지, 12(3), pp.373~379 (2018), 한국방사선학회[DOI]

관련 논문AI추천

이 간행물의 다른 논문 (5건)