국내 유방촬영 방사선량 평가 및 국내·외 진단참고수준 조사 분석

Evaluation of Radiation Dose for Mammography and Analysis of National Diagnostic Reference Levels

1

조회

0

다운로드

1

인용

0

참고문헌

키워드

초록

Mammography is an important medical tool used to diagnose breast cancer. The usageof mammography is continuously increasing due to the development of the medical industry inKorea. The glandular tissue which is sensitive to radiation is exposed during mammography, so itis necessary to manage the patient dose for mammography. Therefore, the objective of this studyis to evaluate the radiation dose for mammography and to investigate and analyze domestic andforeign diagnostic reference levels. In this study, radiation dose assessment methodology based onMonte-Carlo was established for the evaluation of patient radiation dose by mammography. Thestudies on the diagnostic reference level of countries and associations such as the United States,Australia, Spain, Ireland, Bulgaria, and Slovenia were investigated. In Korea, the studies on themammography diagnostic reference level conducted by the Ministry of Food and Drug Safety(MFDS) and the Korea Centers for Disease Control and Prevention (KCDC) were investigated. As a result of evaluating the mean glandular dose and effective dose by mammography usingthe MCNP program, the mean glandular dose and effective dose for the compression breastthickness range of 4~5 cm which is largest number of patients in Korea were 1.36 mGy, 0.163mSv and 1.34 mGy, 0.161 mSv for CC and MLO. In a study conducted by the KCDC in 2018,the mammography diagnostic reference level for phantom and patient was established. Thediagnostic reference level for phantom was 1.59 mGy, which was 14% and 18% higher thanKorea in 2007 and Australia, and 26%, 45%, 7% lower than US, Bulgaria, and Slovenia. Thediagnostic reference level for patient was 1.97 and 1.98 mGy in the CC and MLO, similar to Spainand higher than other countries and associations. The result of patient radiation dose evaluationfor mammography and domestic and foreign diagnostic reference level analysis conducted in thisstudy can be used as basic data for reducing patient dose by mammography in Korea.

Abstract

Mammography is an important medical tool used to diagnose breast cancer. The usageof mammography is continuously increasing due to the development of the medical industry inKorea. The glandular tissue which is sensitive to radiation is exposed during mammography, so itis necessary to manage the patient dose for mammography. Therefore, the objective of this studyis to evaluate the radiation dose for mammography and to investigate and analyze domestic andforeign diagnostic reference levels. In this study, radiation dose assessment methodology based onMonte-Carlo was established for the evaluation of patient radiation dose by mammography. Thestudies on the diagnostic reference level of countries and associations such as the United States,Australia, Spain, Ireland, Bulgaria, and Slovenia were investigated. In Korea, the studies on themammography diagnostic reference level conducted by the Ministry of Food and Drug Safety(MFDS) and the Korea Centers for Disease Control and Prevention (KCDC) were investigated. As a result of evaluating the mean glandular dose and effective dose by mammography usingthe MCNP program, the mean glandular dose and effective dose for the compression breastthickness range of 4~5 cm which is largest number of patients in Korea were 1.36 mGy, 0.163mSv and 1.34 mGy, 0.161 mSv for CC and MLO. In a study conducted by the KCDC in 2018,the mammography diagnostic reference level for phantom and patient was established. Thediagnostic reference level for phantom was 1.59 mGy, which was 14% and 18% higher thanKorea in 2007 and Australia, and 26%, 45%, 7% lower than US, Bulgaria, and Slovenia. Thediagnostic reference level for patient was 1.97 and 1.98 mGy in the CC and MLO, similar to Spainand higher than other countries and associations. The result of patient radiation dose evaluationfor mammography and domestic and foreign diagnostic reference level analysis conducted in thisstudy can be used as basic data for reducing patient dose by mammography in Korea.

참고문헌 (26)

  1. 식품의약품안전청, "유방촬영시 환자피폭선량 진단참고수준 확립", ~ (2007)
  2. 질병관리본부, "환자 촬영종류별 진단참고수준 마련: 유방 및 일반촬영 12개 종류 추가", ~ (2018)
  3. 의료방사선 이용에 따른 국민방사선량 평가 연구, "질병관리본부", ~ (2020)
  4. ACR, "Mammography quality control manual", American College of Radiology, ~ (1999)
  5. Avramova-Cholakova S, "A survey of the state of mammography practice in Bulgaria", Radiat. Prot. Dosim, 147, pp.184~ (2011)
  6. Dance DR, "The monte carlo calculation of integral radiation dose in xeromammography", Phys. Med. Biol, 25, pp.25~37 (1980)
  7. EC, "European protocol on dosimetry in mammography", Office for official publications of the European communities, ~ (1996)
  8. EC, "European guidelines for quality assurance in mammography screening", Office for official publications of the European communities, ~ (2001)
  9. EC, "European guidelines for quality assurance in breast cancer screening and diagnosis" (2006), Luxembourg office for official publications of the European Communities
  10. Geeraert N, "Breast characteristics and dosimetric data in X-ray mammography a large sample worldwide survey", IAEA conference (2012)
  11. Gennaro G, "Dose comparison between screen", film and full-field digital mammography, 2006, pp.16, 2559~2566
  12. International Basic Safety Standards for Protection against Ionizing Radiation and for the Safety of Radiation Sources, "IAEA", ~, pp.IAEA Safety Series No. 115 (1996)
  13. IAEA, "Dosimetry in diagnostic radiology: an international code of practice", International Atomic Energy Agency, ~ (2007)
  14. Protection of the patient in nuclear medicine, "ICRP", ~, pp.ICRP Publication 52 (1987)
  15. Radiology protection and safety in medicine, "ICRP", ~, pp.ICRP Publication 73 (1996)
  16. Diagnostic reference levels in medical imaging, "ICRP", ~, pp.ICRP Publication 135 (2017)
  17. Karlsson M, "Absorbed dose in mammary radiography", Acta. Radiol. Ther. Phys. Biol, 15(3), pp.252~258 (1976)
  18. Ko KO, "Assessment of patient close in mammography using monte carlo simulation", J. Nuclear Sci. Technol, 41, pp.215~218 (2004)
  19. Morán P, "A survey of patient dose and clinical factors in a full-field digital mammography system", Radiat. Prot. Dosim, 114, pp.375~379 (2005)
  20. Mammography: A user’s guide, "NCRP", ~, pp.NCRP Report No.85 (1986)
  21. O’Leary D, "A comparison of mean glandular dose diagnostic reference levels within the all-digital Irish National Breast Screening Programme and the Irish Symptomatic Breast Services", Radiat. Prot. Dosim, 153, pp.300~308 (2013)
  22. Spelic DC, "United States radiological health activities: inspection result of mammography facilities", Biomed. Imaging Interv. J, 3(2), pp.e35~ (2007)
  23. Tabar L, "Swedish two-county trial: impact of mammography screening on breast cancer mortality during 3 decades", Radiology, 260, pp.658~663 (2011)
  24. Thiele DL, "Diagnostic reference levels for mammography in BreastScreen Queensland", Australas Phy. Eng. Sci. Med, 34, pp.415~418 (2011)
  25. Wu X, "Spectral dependence of glandular tissue dose in screen-film mammography", Radio-logy, 179, pp.143~148 (1991)
  26. Zdesar U, "Reference levels for image quality in mammography", Radiat. Prot. Dosim, 129, pp.170~172 (2008)

관련 논문AI추천

이 간행물의 다른 논문 (5건)