본문 바로가기
KERD
논문KCI 등재

두꺼운 피사체 X선 촬영 시 보호앞치마 착용의 유용성

Utility of Wearing Protective Apron for X-ray of Thick Subject

2

조회

0

다운로드

0

인용

0

참고문헌

키워드

초록

This study examined the effectiveness degree of a protective apron that is taken not to be exposed to the first ray or scattered rays, for X-ray of thick subject like lateral lumbar, and the results are as follows; First, spatial dose by scattered rays is shielded by 3 mmPb protective apron, 86.8% at a distance of 50 cm, 92.7% at 100 cm, and 95.6% at 200 cm, when minimizing the field size, while 89% at a distance of 50 cm, 92.3% at 100 cm, and 95.2% at 200 cm, when maximizing the field size. Second, 1st exposure dose is shielded by 3 mmPb protective apron, 93.7% at a distance of 50 cm, 94.4% at 100 cm, and 93.6% at 200 cm, when minimizing the field size, while 93.7% at a distance of 50 cm, 93.6% at 100 cm, and 94.2% at 200 cm, when maximizing the field size.

Abstract

This study examined the effectiveness degree of a protective apron that is taken not to be exposed to the first ray or scattered rays, for X-ray of thick subject like lateral lumbar, and the results are as follows; First, spatial dose by scattered rays is shielded by 3 mmPb protective apron, 86.8% at a distance of 50 cm, 92.7% at 100 cm, and 95.6% at 200 cm, when minimizing the field size, while 89% at a distance of 50 cm, 92.3% at 100 cm, and 95.2% at 200 cm, when maximizing the field size. Second, 1st exposure dose is shielded by 3 mmPb protective apron, 93.7% at a distance of 50 cm, 94.4% at 100 cm, and 93.6% at 200 cm, when minimizing the field size, while 93.7% at a distance of 50 cm, 93.6% at 100 cm, and 94.2% at 200 cm, when maximizing the field size.

참고문헌 (14)

  1. An SM, "A Study on Scattered Dose in Operation Room by C-arm Unit", J. Soc. Radiol. Technol, 23(2), pp.69~73 (2000)
  2. 조평곤, "앉은 자세 상지 X-ray 검사(Sitting Position Upper Extremity X-ray Examinations)에서 피폭선량 저감화 연구", 방사선기술과학, 34(3), pp.189~193 (2011), 대한방사선과학회
  3. 전미은, "방사선 중재적 시술 중 시술자의 피폭선량에 대한 연구", 방사선기술과학, 35(3), pp.219~226 (2012), 대한방사선과학회
  4. Kim CK, "Spatial Dose Distribution and Exposure Dose During Lumbar Lateral Test", J. Korea Converg. Soc, 5(1), pp.17~22 (2014)
  5. 김기원, "방사선 방어용 앞치마의 납당량, 형태에 따른 성능 평가", 방사선산업학회지, 10(4), pp.219~225 (2016), (사)한국방사선산업학회
  6. Kim YH, "Patient exposure doses from medical x-ray examinations in Korea", J. Soc. Radiol. Technol, 28(3), pp.241~248 (2005)
  7. Kim YK, "Improvement of the shieldability and lightweight of a radiation protective apron", J. Soc. Radiol. Technol, 26(1), pp.45~50 (2003)
  8. 고신관, "중재적 방사선 분야 방호용구 차폐효과", 방사선기술과학, 30(3), pp.213~218 (2007), 대한방사선과학회
  9. Orhan O, "How protective are the lead aprons we use against ionizing radiation", Diagn. Interv. Radiol, 18(2), pp.147~152 (2012)
  10. 박명환, "X선 및 감마선에 대한 apron의 차폐율 측정", 방사선기술과학, 30(3), pp.245~250 (2007), 대한방사선과학회
  11. Sin KS, "Radiation Physics", pp.110~ (2005), Sinkwang Publishing Company
  12. 송종남, "Over Tube Type의 투시촬영장치를 이용한 제조사별, 납당량별 엑스선방어 앞치마의 Protection 성능 평가에 관한 연구", 한국방사선학회논문지, 5(3), pp.135~141 (2011), 한국방사선학회
  13. Stam W, "Inspection of lead aprons: A practical rejection model", Health Phys, 95(2), pp.133~136 (2008)
  14. Yang HJ, "Evaluation of Performance Test for Protective Aprons", J. Soc. Radiol. Technol, 16(2), pp.73~79 (1993)

관련 논문AI추천