The purpose of this study is to provide the basic data for reducing unnecessary radiation dose to the abdomen and fetus of pregnant women by presenting proper height of shielding protector for efficient abdominal shielding in chest PA examination of Korean pregnant women. The subjects of this study were 288 persons who were eligible for this study among 798 pregnant women who had chest PA examination from January 1, 2015 to December 31, 2016 Retrospective study was performed. Measurements was performed from the apex of the right and left lungs to costophrenic angle of the right and left lungs and to the lowest costophrenic angle among the right and left lungs at the top of the image(this line called Joo's line in this study). The mean of the right and left lung height of pregnant women were 259.09㎜ and 263.57㎜, respectively. Also, the average height of the Joo's line designed by the researcher for proper abdominal radiation protection was 322.15㎜. For proper and efficient abdominal radiation protection for pregnant women, it is necessary to adjust the shielding according to the height of the pregnant woman. It is appropriate that the height of the shielding protector should be adjusted so that the upper part of the shield is located at 342.30 ㎜ below from upper part of the detector.
Abstract
The purpose of this study is to provide the basic data for reducing unnecessary radiation dose to the abdomen and fetus of pregnant women by presenting proper height of shielding protector for efficient abdominal shielding in chest PA examination of Korean pregnant women. The subjects of this study were 288 persons who were eligible for this study among 798 pregnant women who had chest PA examination from January 1, 2015 to December 31, 2016 Retrospective study was performed. Measurements was performed from the apex of the right and left lungs to costophrenic angle of the right and left lungs and to the lowest costophrenic angle among the right and left lungs at the top of the image(this line called Joo's line in this study). The mean of the right and left lung height of pregnant women were 259.09㎜ and 263.57㎜, respectively. Also, the average height of the Joo's line designed by the researcher for proper abdominal radiation protection was 322.15㎜. For proper and efficient abdominal radiation protection for pregnant women, it is necessary to adjust the shielding according to the height of the pregnant woman. It is appropriate that the height of the shielding protector should be adjusted so that the upper part of the shield is located at 342.30 ㎜ below from upper part of the detector.
참고문헌 (11)
- Park JH, "Analysis of 1968 cases of preoperative laboratory screening test results", Korean journal of anesthesilolgy, 36, pp.923~928 (1999)[DOI]
- 진성진, "디지털 흉부 방사선 영상의 체질량지수에 따른 영상품질 분석: 미국 방사선 안전국 규정 평가표 중심으로", 방사선기술과학, 40(1), pp.1~6 (2017), 대한방사선과학회[DOI]
- 이인자, "흉부 디지털 방사선 촬영 시 C-D phantom을 이용한 촬영조건에 따른 영상 평가", 방사선기술과학, 32(1), pp.25~32 (2009), 대한방사선과학회
- 길종원, "국가건강검진의 방사선검사 이용량 및 피폭선량 추정", 방사선방어학회지, 39(3), pp.142~149 (2014), 테스트학회
- National Health Insurance, "2015 Major surgery Statistical Yearbook", pp.25~ (2015)
- Donnelly EH, "Prenatal radiation exposure: background material for counseling pregnant patients following exposure to radiation", Disaster Med Public Health Prep., 5(1), pp.62~68 (2011)[DOI]
- 김기진, "임산부 흉부촬영 시 복부차폐의 적정성 평가", 대한안전경영과학회지, 17(4), pp.207~212 (2015), 대한안전경영과학회[DOI]
- International commission on radiological protection, "ICRP publication 84 Pregnancy and medical radiation" (1999)
- 박정규, "경북 지역 산부인과 환자의 방사선피폭 인식", 한국콘텐츠학회 논문지, 8(8), pp.176~187 (2008), 한국콘텐츠학회
- Clemente Cramine D, "Anatomy, A regional atlas of the human body. 3rd", pp.399~ (1987), Urban&Schwarzenber
- Kim WG, "A study of the size of lung by radiographic method in normal Korean", Journal of Korean Society of radiological technology, 1(1), pp.69~73 (1978)