자동노출조절장치를 이용한 흉부 방사선검사 시 갑상샘 장기선량 최소화를 위한 새로운 차폐 방법에 관한 연구
A Study on New Shielding Method for Minimizing Thyroid Oran Dose on Chest Radiography Used Automatic Exposure Control
2
조회
0
다운로드
3
인용
0
참고문헌
키워드
초록
The purpose of this study is to investigate the effect of radiation shielding on the thyroid organ dose and image quality during Chest PA examination using automatic exposure control system. This study was conducted in the patient posture and examination conditions such as Chest PA using human model phantom. An experiment without shielding was set as a control group (non) and the cases of using paper coated with a contrast agent (contrast) and bismuth (bismuth) were used as experimental groups. Compared to non-shielded(non), the dose at bismuth increased about 7% in C(cervical vertebrae)5 and C6 and 14% in C7 and contrast showed dose increases of about 17 to 19% in C5 and C6 and about 21% in C7. As a result of the image quality comparison, when measured in the center of the cervical vertebrae, both SNR and CNR in bismuth increased about 40% higher than non, and contrast showed about 8 to 9% improvement. Compared with soft tissues of the cervix, bismuth reduced SNR by about 15% and CNR by about 13%, in contrast, SNR decreased by 11%, and CNR decreased by about 10%. In the Chest PA using AEC, the method of using the shield in front of the collimator has the advantage to observe the anatomical structure of the neck area well compared to the method using the lead. However, the dose at the neck can be increased by 7-21% depending on shielding materials.
Abstract
The purpose of this study is to investigate the effect of radiation shielding on the thyroid organ dose and image quality during Chest PA examination using automatic exposure control system. This study was conducted in the patient posture and examination conditions such as Chest PA using human model phantom. An experiment without shielding was set as a control group (non) and the cases of using paper coated with a contrast agent (contrast) and bismuth (bismuth) were used as experimental groups. Compared to non-shielded(non), the dose at bismuth increased about 7% in C(cervical vertebrae)5 and C6 and 14% in C7 and contrast showed dose increases of about 17 to 19% in C5 and C6 and about 21% in C7. As a result of the image quality comparison, when measured in the center of the cervical vertebrae, both SNR and CNR in bismuth increased about 40% higher than non, and contrast showed about 8 to 9% improvement. Compared with soft tissues of the cervix, bismuth reduced SNR by about 15% and CNR by about 13%, in contrast, SNR decreased by 11%, and CNR decreased by about 10%. In the Chest PA using AEC, the method of using the shield in front of the collimator has the advantage to observe the anatomical structure of the neck area well compared to the method using the lead. However, the dose at the neck can be increased by 7-21% depending on shielding materials.
참고문헌 (10)
- 김대훈, "질감분석을 이용한 폐결핵의 자동진단", 한국콘텐츠학회 논문지, 11(11), pp.185~193 (2011), 한국콘텐츠학회
- Veldhamp WJH, "Dose and perceived image qualigy in chest radiography", Eropaean Journaral of Radiologry, 72(2), pp.209~217 (2009)
- 최성식, "흉부 방사선검사에서 자동노출제어 사용에 관한 연구", 방사선기술과학, 42(1), pp.19~24 (2019), 대한방사선과학회[DOI]
- 주영철, "흉부 방사선검사 영상을 이용한 한국인 정상 여성의 임신기와 비 임신기 심장크기와 심흉비 비교", 방사선기술과학, 41(3), pp.223~229 (2018), 대한방사선과학회[DOI]
- Park JH, "Analysis of 1968cases of preoperative laboratory screening test results", Korean Journal of Anesthesilolgy, 36, pp.923~928 (1999)
- 김종순, "갑상선암과 방사선", International Journal of Thyroidology, 8(1), pp.1~7 (2015), 대한갑상선학회
- Sung DW, "Radiation exposure in diagnostic areas : issues and countermeasures", J Korean Med Assoc, 54(12), pp.1246~1247 (2011)
- 정명진, "우리나라의 흉부엑스선검사에서의 환자선량 권고량", 대한영상의학회지, 62(6), pp.523~528 (2010), 대한영상의학회
- 이준호, "소아(10세) 흉부 방사선촬영에서의 두경부 방사선 방어기구 개발 및 평가", 방사선방어학회지, 40(2), pp.118~123 (2015), 테스트학회
- Vahid K, "Dose reduction to the thyroid gland in pediatric chest raiography", International Journal of Pediatrics, 4(7), pp.2183~2191 (2016)
