3D 프린팅기술을 이용한 골밀도 정도관리 대퇴골 팬텀 제작 및 유용성 평가

Evaluation of Usefulness and Fabrication of Femur Phantom on Quality Control of Bone Mineral Density Using 3D Printing Technology

1

조회

0

다운로드

2

인용

0

참고문헌

키워드

주제분류방사선과학

초록

As the demand for bone mineral density testing increases in Korea, which is close to an aging society, it is necessary to evaluate the repeatability of equipment such as femur phantom other than l-spine for more accurate diagnosis. However, in clinical practice, it is often not possible to proceed such evaluation due to insufficient quality control conditions. Therefore, this study is to evaluate the usefulness of the femur phantom after fabricating the same using 3D printing technology. The femur phantom was output using GlowFill filament and FDM 3D printing type. Each phantom was repeatedly scaned 20 times to compare whether the existing l-spine phantom and the fabricated femur phantom were suitable as a phantom for quality control. Each time the seven researchers took three times, the location of the femur phantom was readjusted, and then scanned to confirm the error between the researchers. As a result of conducting repeatability evaluation using femur phantom, the coefficient of variation rate was 2%, which was within the minimum precision tolerance of 2.5%. The reproducibility between the researcher was also found to be suitable as the average coefficient of variation was 0.031 and the coefficient of variation rate was 3.1%, which was within the minimum precision error range of 5%. In conclusion, it is considered that the prospective attitude and usefulness of the femur phantom fabricated by 3D printing in clinical practice will be sufficient.

Abstract

As the demand for bone mineral density testing increases in Korea, which is close to an aging society, it is necessary to evaluate the repeatability of equipment such as femur phantom other than l-spine for more accurate diagnosis. However, in clinical practice, it is often not possible to proceed such evaluation due to insufficient quality control conditions. Therefore, this study is to evaluate the usefulness of the femur phantom after fabricating the same using 3D printing technology. The femur phantom was output using GlowFill filament and FDM 3D printing type. Each phantom was repeatedly scaned 20 times to compare whether the existing l-spine phantom and the fabricated femur phantom were suitable as a phantom for quality control. Each time the seven researchers took three times, the location of the femur phantom was readjusted, and then scanned to confirm the error between the researchers. As a result of conducting repeatability evaluation using femur phantom, the coefficient of variation rate was 2%, which was within the minimum precision tolerance of 2.5%. The reproducibility between the researcher was also found to be suitable as the average coefficient of variation was 0.031 and the coefficient of variation rate was 3.1%, which was within the minimum precision error range of 5%. In conclusion, it is considered that the prospective attitude and usefulness of the femur phantom fabricated by 3D printing in clinical practice will be sufficient.

참고문헌 (30)

  1. Lee SJ, "Measurement of bone density in Korean adults using dual energy X-ray absorptiometry(DEXA)", Journal of the Korean Society for Bone Metabolism, 1(2), pp.201~208 (1994)
  2. Kim HS, "Management of bone density test using dual energy X-ray absorptiometry", Radiation Technology and Science, 41(4), pp.351~360 (2018)
  3. Yang SO, "Function run. Follow-up of osteoporosis treatment using bone densitometry", Journal of the Korean Endocrinology Society, 16(4), pp.5~ (2001)
  4. Yang JY, "Correlation analysis of proximal femur and lumbar bone density tests", Journal of the Korean Fracture Society, 16(4), pp.570~576 (2003)
  5. Baek KH, "ISCD Official Views on Bone Density Measurement and Clinical Application", Journal of the Korean Endocrinology Society, 20(1) (2005)
  6. Kang YE, "The Clinical Usefulness Measurement of the Whole Body Percent Fat Calculated by the Part Bone Mineral Density Measurement", The Korean Journal of Nuclear Medicine Technology, 15(1), pp.3~9 (2011)
  7. Ku YM, "Relationship between bone mineral density of lumbar spine and fatty replacement of lumbar paraspinal muscles by Quantitative computed tomography", Journal of the Korean Radiological Society, 38(1), pp.163~167 (1998)
  8. 김정수, "이중에너지 방사선흡수 골밀도 장치의 품질관리 현황", 방사선기술과학, 39(4), pp.527~534 (2016), 대한방사선과학회[DOI]
  9. 윤명성, "삼차원 프린팅 기술을 이용한 전산화단층영상 품질 측정용 팬텀 제작 및 비교 연구", 방사선기술과학, 41(6), pp.595~602 (2018), 대한방사선과학회[DOI]
  10. 황선욱, "일개병원 건강 성인 남성의 요추, 대퇴부의 골밀도 특징", Korean Journal of Health Promotion, 9(3), pp.199~206 (2009), 대한임상건강증진학회
  11. Park HM, "Comparative study of whole and partial bone density in the diagnosis of osteoporosis", Journal of the Korean Menopause Society, 9(1), pp.25~35 (2003)
  12. Choi JS, "DEXA T-score concordance and discordance between hip and lumbar spine", Journal of Korean Society of Spine Surgery, 10(2), pp.75~81 (2003)
  13. Shahrubudin N, "An overview on 3D printing technology : Technological, materials, and applications", Procedia Manufacturing, 35, pp.1286~1296 (2019)
  14. 이준호, "3D 프린팅을 이용한 골밀도 팬텀 개발", 한국방사선학회논문지, 13(2), pp.185~192 (2019), 한국방사선학회[DOI]
  15. 윤명성, "CT 데이터와 3D 프린팅 기술을 이용한뼈 모형 X선 팬텀 제작에 관한 연구", 한국방사선학회논문지, 12(7), pp.879~886 (2018), 한국방사선학회[DOI]
  16. 김호성, "골밀도 측정의 정확한 정도관리방법 ― 이중 에너지 방사선 흡수법을 중심으로 ―", 방사선기술과학, 32(4), pp.361~370 (2009), 대한방사선과학회
  17. Kim HS, "Understanding Dual Energy Radiation Absorption Method, Department of Nuclear Medicine, Seoul Central Hospital, Ulsan University of Medicine", Korean Journal of Bone Metabolism, 3(2), pp.128~135 (1996)
  18. 고윤실, "Differences in accuracy of height, weight, and body mass index between self-reported and measured using the 2018 Korea Community Health Survey data", Epidemiology and Health, 44, pp.1~8 (2022), 한국역학회[DOI]
  19. Kim JM, "Innovation Radiation Imaging Informatics Experiment", pp.121~124 (2021), Shinkwang Publisher
  20. Catholic Kwandong University. Education and Quality Control of Bone Mineral Density Test in the Fourth National Health and Nutrition Examination Survey, "Korea Disease Control and Prevention Agency", ~ (2008)
  21. Kim EH, "The Practical Bone Density Test : Focusing on Dual-Energy X-ray Absorptiometry(DXA)", Korean Journal of Medicine(former Journal of Internal Medicine), 94(3), pp.268~272 (2019)
  22. Dong GR, "Clinical application and interpretation according to correct quality management of bone density test-Focused on dual energy radiation absorption method", Radiation Technology and Science, 31(1), pp.17~23 (2008)
  23. 이윤홍, "DEXA를 이용한 골밀도 측정시 검사자의 ROI 변화에 따른 골밀도 측정값의 오차에 관한 연구", 방사선기술과학, 35(1), pp.1~7 (2012), 대한방사선과학회
  24. 김덕윤, "골밀도 측정의 올바른 임상 적용", Nuclear Medicine and Molecular Imaging, 38(4), pp.275~281 (2004), 대한핵의학회
  25. Jung SP, "Factors that affect bone density in postmenopausal women", Yeongnam Medical University, 13(2), pp.261~271 (1996)
  26. 정묘영, "재활치료 환자에서 DXA를 이용한 요추부와 대퇴경부 골밀도 검사의 상관관계", 방사선산업학회지, 12(4), pp.311~316 (2018), (사)한국방사선산업학회[DOI]
  27. 홍성빈, "골다공증의 진단과 치료", 대한신경과학회지, 35(4), pp.20~24 (2017), 대한신경과학회[DOI]
  28. Choplin RH, "A Practical Approach to interpretation of Dual-Energy X-ray absorptiometry for Assessment of Bone Density", Curr Radiol Rep, 2, pp.48~ (2014)
  29. Yoo JS, "The Precision Test Based on States of Bone Mineral Density", The Korean Journal of Nuclear Medicine Technology, 13(1), pp.67~72 (2009)
  30. 김호성, "이중에너지 엑스선 흡광분석법을 이용한 골밀도검사의 관리법", 방사선기술과학, 41(4), pp.351~360 (2018), 대한방사선과학회[DOI]

관련 논문AI추천