삼차원 프린팅 기술을 이용한 전산화단층영상 품질 측정용 팬텀 제작 및 비교 연구
A Study on the Fabrication and Comparison of the Phantom for Computed Tomography Image Quality Measurements Using Three-Dimensions Printing Technology
1
조회
0
다운로드
7
인용
0
참고문헌
키워드
초록
Quality control (QC) of Computed Tomography (CT) devices is based on image quality measurement on AAPM CT phantom which is a standard phantom. Although it is possible to control the accuracy of the CT apparatus, it is expensive and has a disadvantage of low penetration rate. Therefore, in this study, we make image quality measurement phantom at low cost using FFF (Fused Filament Fabrication) type three-dimensional printer and try to analyze the usefulness, compare it with existing standard phantom. To print a phantom, We used three-dimensional printer of the FFF system and PLA (Poly Lactic Acid, density: 1.24 g/cm3) filament, and the CT device of 64 MDCT (Aquilion CX, Toshiba, Japan). In addition, we printed a phantom using three-dimensional printer after design using various tool based on existing standard phantom. For image quality evaluation, AAPM CT phantom and self-generated phantom were measured 10 times for each block. The measured data were analyzed for significance using the Mannwhiteney U-test of SPSS (Version 22.0, SPSS, Chicago, IL, USA). As a result of the analysis, phantom fabricated with three-dimensional printer and standard phantom showed no significant difference (p>0.05). Furthermore, we confirmed that image quality measurement performance of a phantom using three-dimensional printer is similar to the existing standard phantom. In conclusion, we confirmed the possibility of low cost phantom fabrication using three dimensional printer.
Abstract
Quality control (QC) of Computed Tomography (CT) devices is based on image quality measurement on AAPM CT phantom which is a standard phantom. Although it is possible to control the accuracy of the CT apparatus, it is expensive and has a disadvantage of low penetration rate. Therefore, in this study, we make image quality measurement phantom at low cost using FFF (Fused Filament Fabrication) type three-dimensional printer and try to analyze the usefulness, compare it with existing standard phantom. To print a phantom, We used three-dimensional printer of the FFF system and PLA (Poly Lactic Acid, density: 1.24 g/cm3) filament, and the CT device of 64 MDCT (Aquilion CX, Toshiba, Japan). In addition, we printed a phantom using three-dimensional printer after design using various tool based on existing standard phantom. For image quality evaluation, AAPM CT phantom and self-generated phantom were measured 10 times for each block. The measured data were analyzed for significance using the Mannwhiteney U-test of SPSS (Version 22.0, SPSS, Chicago, IL, USA). As a result of the analysis, phantom fabricated with three-dimensional printer and standard phantom showed no significant difference (p>0.05). Furthermore, we confirmed that image quality measurement performance of a phantom using three-dimensional printer is similar to the existing standard phantom. In conclusion, we confirmed the possibility of low cost phantom fabrication using three dimensional printer.
참고문헌 (18)
- Jang W, "Current status and main issues of Korean medical resources in OECD statistics", HIRA, 4, pp.7~16 (2018)
- Mitsumori LM, "Adaptive statistical iterative reconstruction versus filtered back projection in the same patient : 64 channel liver CT image quality and patient radiation dose", European radiology, 22(1), pp.138~143 (2012)
- 임청환, "전산화단층촬영 검사의 방사선 선량에 관한 연구", 방사선기술과학, 30(4), pp.381~389 (2007), 대한방사선과학회
- Kwon OT, "Selection criteria of medical equipment requiring quality control and selection of priority medical equipment", HIRA, 3, pp.33~48 (2018)
- Yoo MS., "The study of rationalization between dose and image quality using ACR phantom with abdominal computed tomography(CT)", master’s, pp.2018
- Mettler Jr FA, "CT scanning : patterns of use and dose", J Radiol Prot, 20(4), pp.353~359 (2000)
- Lee JH, "OECD Statistics on Primary Health Care in Korea and Major Issues", HIRA, 4, pp.17~32 (2018)
- Payne JT, "CT radiation dose and image quality", Radiol Clin N Am, 43, pp.953~962 (2005)
- Kim KK., "Study on Measuring scan parameter of CTDI(Computed Tomograhy Dose Index", master’s, pp.2011
- Yoon MS., "A Study on CT image quality and dosemeasurement Phantom using 3D printer", master’s, pp.2018
- Lee GB., "The Study on Automatized Quantitative Assessment Method in CT Phantom Image Evaluation:Focusing on Spatial and Low Contrast Resolution", master’s, pp.2016
- 한동균, "MDCT에서 화질과 방사선량에 관한 연구", 방사선기술과학, 30(2), pp.129~138 (2007), 대한방사선과학회
- Oh WG, (2014), University of Choong Book
- Todd L, "Material Property Testing of 3D-Printed Specimen in PLA on an Entry-Level 3D Printer", J ASME, 14(20), pp.3~8 (2014)
- Becker HC, "Radiation exposure and image quality of normal computed tomography brain images acquired with automated and organ-based tube current modulation multiband filtering and iterative reconstruction", Investigative radiology, 47(3), pp.202~207 (2012)
- Stein KM, "Quality assurance in CT", Radiol Technol, 72(1), pp.67~75 (2000)
- 성열훈, "3D 프린터로 제작된 CT 팬톰을 이용한 물리적 관심영역과 설정 관심영역의 크기에 따른 하운스필드의 비교", 방사선기술과학, 38(4), pp.421~427 (2015), 대한방사선과학회[DOI]
- 최우전, "3D 프린팅을 활용한 일반 X선 촬영 실습용 인체 팬텀 제작", 한국방사선학회논문지, 11(5), pp.371~377 (2017), 한국방사선학회[DOI]