본문 바로가기
KERD
논문KCI 등재

골밀도 검사자의 정밀도 평가

Accuracy Evaluation of Bone Density Examiner

0

조회

0

다운로드

0

인용

0

참고문헌

키워드

초록

Currently, the prevalence of osteoporosis is increasing with the increase of the elderly population. Thebone density test is an important medical test that helps to detect and prevent health problems such as osteoporosisearly by measuring bone density. The purpose of this study is to find out whether numerical results can be reproducedequally without biological changes. The measured values are calculated using the calculation table distributed byISCD to calculate the precision for each part. The subjects measured 30 times in 30 subjects twice, and AP Spine, LeftFemur Neck, and Left Femur Total were measured. The part that most affected the result value during the examinationwas the patient’s test posture and ROI level. If the patient’s examination posture is not accurate, the value will pop orthe accuracy will be reduced in performing a follow-up examination. In addition, if the patient’s Spine Level is notaccurately caught from L1 to L4, the BMD value will be incorrect. The LSC value of AP Spine was 0.46%, FemurNeck was 0.49% and Femur Total was 0.42%, indicating precise result values below the evaluation criteria of ISCD. Therefore, the result value will be a good transition data for subsequent researchers, and follow-up tests can be mademore precise for future patients.

Abstract

Currently, the prevalence of osteoporosis is increasing with the increase of the elderly population. Thebone density test is an important medical test that helps to detect and prevent health problems such as osteoporosisearly by measuring bone density. The purpose of this study is to find out whether numerical results can be reproducedequally without biological changes. The measured values are calculated using the calculation table distributed byISCD to calculate the precision for each part. The subjects measured 30 times in 30 subjects twice, and AP Spine, LeftFemur Neck, and Left Femur Total were measured. The part that most affected the result value during the examinationwas the patient’s test posture and ROI level. If the patient’s examination posture is not accurate, the value will pop orthe accuracy will be reduced in performing a follow-up examination. In addition, if the patient’s Spine Level is notaccurately caught from L1 to L4, the BMD value will be incorrect. The LSC value of AP Spine was 0.46%, FemurNeck was 0.49% and Femur Total was 0.42%, indicating precise result values below the evaluation criteria of ISCD. Therefore, the result value will be a good transition data for subsequent researchers, and follow-up tests can be mademore precise for future patients.

참고문헌 (13)

  1. Kim JS, "A Status Report on Dual Energy X-ray Absorptiometry Quality Control in Korea", JRST, 39(4), pp.527~534 (2016)[DOI]
  2. Lee IJ, "Predictive of Osteoporosis by Treebased Machine Learning Model in Post-menopause Woman", J Radiol. Sci. Technol, 43(6), pp.495~502 (2020)[DOI]
  3. Yuk GT, "Analysis on Bone Density and Body Composition of Long Distance Female Elite Athletics and Normal Women", pp.2012
  4. The study on bone mineral density measurement error in accordance with change in ROI by utilizing dual energy X-ray opsorptiometry, "Lee YH", KRN, 1~7 (2012)
  5. Kim HS, "Appropriate image quality management method of bone mineral density measurement", Korean Content Society Comprehensive Academic Conference Papers, 7(1), pp.1141~1149 (2009)
  6. Hong DH, "A Study on the Result of Test Site on BMD", J Radiol. Sci. Technol, 36(1), pp.19~24 (2013)
  7. Ro HK, "Significance of Bone Mineral Density Measurement in Various Site of Bone", CMJ, 22(2), pp.117~122 (1995)
  8. Han MS, "The Position for Measuring BMD of the Distal Radius and The Study of the Correlation Between the Distal Radius and Lumba", J Radiol. Sci. Technol, 33(1), pp.19~24 (2010)
  9. Jang JS, "Comparative Study of Femur BMD and Lumbar BMD Measurement Using Dual Energy X-ray Absorptiometry in Proximal Femur Fractures", JBM, 3(2), pp.170~173 (1996)
  10. Yoon J, "The Influences of Bowel Condition with Lumbar Spine BMD Measurement", J Radiol. Sci. Technol, 37(4), pp.273~278 (2014)
  11. Lim JW, "Load Sharing Ratios Between the Cortex and Centrum in a Lumbar Vertebral Body with aging using Finite Element Method", JBER, 37(2), pp.90~103 (2016)
  12. Chun SW, "Effects of Swimming Exercise and Combined Exercise for 16 Weeks on Bone Mineral Density and Health-related Physical Fitness of Elementary School Boys", Department of Sport Science, pp.2013
  13. Kim HS, "Reduction of the Useless Radiation Exposure to Patients and Improvement of the Skill to Manage the Test according to Minimizing Changes of Posture in Bone Mineral Density", JKCA, 9(4), pp.228~235 (2009)

관련 논문AI추천