본문 바로가기
KERD
논문KCI 등재

어린이 부비동 엑스선 검사에서 검사자의 갑상선 차폐 효과성에 관한 연구

Study on the Effectiveness of Radiological Technologist’s Thyroid Shielding in Pediatric Paranasal Sinus X-ray Examination

1

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류방사선과학

초록

During paranasal sinus X-ray examinations in children, the radiological technologist’s thyroid shield is often not implemented to shorten the examination time. This study measured the radiation exposure before and after the implementation of thyroid shielding by analyzing the difference in radiation exposure, the radiological technologist’s could receive depending on the actual thyroid shielding. In the left TLD, when thyroid shielding was not performed(N), the radiation exposure dose(mSv) was 2.869 for the depth dose[Hp(10)] and 2.886 for the surface dose[H(3)], and when thyroid shielding was performed(Y), the Hp(10) was 0.033 and the H(3) was 0.034. In the right TLD, when thyroid shielding was not performed(N), the radiation exposure dose was 3.149 for Hp(10) and 3.137 for H(3), and when thyroid shielding was performed, the Hp(10) of (Y) was 0.013 and the H(3) was 0.015. The differences in the overall exposure dose measurement values are all statistically significant (p<0.05). The difference in radiation dose between when thyroid shielding was not performed and when thyroid shielding was performed was more than 99.2% in both cases, indicating a high radiation shielding rate.

Abstract

During paranasal sinus X-ray examinations in children, the radiological technologist’s thyroid shield is often not implemented to shorten the examination time. This study measured the radiation exposure before and after the implementation of thyroid shielding by analyzing the difference in radiation exposure, the radiological technologist’s could receive depending on the actual thyroid shielding. In the left TLD, when thyroid shielding was not performed(N), the radiation exposure dose(mSv) was 2.869 for the depth dose[Hp(10)] and 2.886 for the surface dose[H(3)], and when thyroid shielding was performed(Y), the Hp(10) was 0.033 and the H(3) was 0.034. In the right TLD, when thyroid shielding was not performed(N), the radiation exposure dose was 3.149 for Hp(10) and 3.137 for H(3), and when thyroid shielding was performed, the Hp(10) of (Y) was 0.013 and the H(3) was 0.015. The differences in the overall exposure dose measurement values are all statistically significant (p<0.05). The difference in radiation dose between when thyroid shielding was not performed and when thyroid shielding was performed was more than 99.2% in both cases, indicating a high radiation shielding rate.

참고문헌 (20)

  1. Rhee DB, "A Study on the comparison of the radiation exposure dose to the image quality of phantom chest radiography using a radiographic assist device", New Physics, 68(7), pp.801~811 (2018)[DOI]
  2. Rhee DB, "A study on chest X-ray using ancillary device for child radiography", Journal of Biomedical Engineering Research, 39(1), pp.48~54 (2018)[DOI]
  3. Yoon YS, "Korean diagnostic reference level for general radiography and mammography in 2022", Public Health Weekly Report, 16, pp.1082~1100 (2023)[DOI]
  4. "1990 recommendations of the international commission on radiological protection. International Commission on Radiological Protection" (1991)[URL]
  5. "The 2007 recommendations of the international commission on radiological protection" (2007)[URL]
  6. "1996 recommendations of the international commission on radiological protection" (1996)[URL]
  7. Eo H, "Development of diagnostic reference levels(DRL)in fluoroscopy", Public Health Weekly Report, 14, pp.1633~1647 (2021)
  8. Ji MH, "The nation public awareness on medical radiation using structural equations model", Public Health Weekly Report, 16, pp.1289~1305 (2023)[DOI]
  9. Rhee DB, "Development of children’s X-ray imaging assist device", Journal of Radiological Science and Technology, 43(4), pp.243~249 (2020)[DOI]
  10. ICRP, "Conversion coefficients for use in radiological protection against external radiation. International Commission of Radiological Protection. ICRP Publication 74", Oxford, Pergamon Press; (1997)[DOI]
  11. Regulla DF, "Patient exposure in medical X-ray imaging in Europe", Radiat Prot Dosimetry, 114(1-3), pp.11~25 (2005)[DOI]
  12. Kim, "Research of awareness for medical radiation safety in radiography", Journal of Radiological Science and Technology, 41(3), pp.255~260 (2018)
  13. "Act on protective action guidelines against radiation in the natural environment" (2017)[URL]
  14. Marazziti D, "Cognitive, psychological and psychiatric effects of ionizing radiation exposure", Curr Med Chem, 19(12), pp.1864~1869 (2012)
  15. Tang FR, "Low dose or low dose rate ionizing radiation-induced health effect in the human", J Environ Radioact, 192, pp.32~47 (2018)[DOI]
  16. Upton AC, "The dose-response relation in radiation-induced cancer", Cancer Res, 21, pp.717~729 (1961)
  17. Rugh R, "Low levels of x-irradiation and the early mammalian embryo", Am J Roentgenol Radium Ther Nucl Med, 87, pp.559~566 (1962)
  18. Yun JH, "Effective dose determination from CT head & neck region", Journal of Radiological Science and Technology, 34(2), pp.105~116 (2011)
  19. "Radiation and human body. Pediatric radiation exposure dose"[URL]
  20. "Health information" (2007)[URL]

관련 논문AI추천