소아 X선 촬영조건 변화에 따른 소아 및 촬영보조자 선량
Doses of Pediatric and X-ray Examination Assistants according to Changes in Pediatric X-ray Exposure Conditions
1
조회
0
다운로드
1
인용
0
참고문헌
키워드
초록
Although pediatric X-ray examinations are continuously increasing, there are not many studies on the radiation exposure to children and X-ray examination assistants according to X-ray Exposure conditions. Accordingly, we measured the radiation exposure dose of pediatric and X-ray examination assistants according to the standard guidelines and clinical average X-ray Exposure conditions when X-ray examination 10-year-old children. The effective dose and organ dose to pediatric were measured using an Dose area production meter and Monte Carlo-based PCXMC program, and the exposure dose of X-ray examination assistants was measured using an ion-chamber. When performing abdominal supine AP projection, the effective dose to children was up to 2.38 times higher under clinical average X-ray Exposure conditions than the standard guidelines. In addition, during abdominal supine AP projection, the radiation exposure dose to the X-ray examination assistants was highest on the hands at 0.0148 ∼ 0.0709 mSv, and exposure dose could be reduced by up to 35% when wearing protective gloves. In conclusion, because the X-ray Exposure conditions used in clinical are unnecessarily high, unnecessary medical radiation exposure could be reduced if appropriate X-ray Exposure conditions and the radiation field area were minimized and the assistant wore shielding gloves.
Abstract
Although pediatric X-ray examinations are continuously increasing, there are not many studies on the radiation exposure to children and X-ray examination assistants according to X-ray Exposure conditions. Accordingly, we measured the radiation exposure dose of pediatric and X-ray examination assistants according to the standard guidelines and clinical average X-ray Exposure conditions when X-ray examination 10-year-old children. The effective dose and organ dose to pediatric were measured using an Dose area production meter and Monte Carlo-based PCXMC program, and the exposure dose of X-ray examination assistants was measured using an ion-chamber. When performing abdominal supine AP projection, the effective dose to children was up to 2.38 times higher under clinical average X-ray Exposure conditions than the standard guidelines. In addition, during abdominal supine AP projection, the radiation exposure dose to the X-ray examination assistants was highest on the hands at 0.0148 ∼ 0.0709 mSv, and exposure dose could be reduced by up to 35% when wearing protective gloves. In conclusion, because the X-ray Exposure conditions used in clinical are unnecessarily high, unnecessary medical radiation exposure could be reduced if appropriate X-ray Exposure conditions and the radiation field area were minimized and the assistant wore shielding gloves.
참고문헌 (17)
- "BEIR Ⅶ Report: Health risks from exposure to low levels of ionising radiation: BEIR Ⅶ Phase 2" (2006)[URL]
- 정아영, "소아촬영의 방사선 피폭과 저감화 방법", 대한의사협회지, 54(12), pp.1277~1283 (2011), 대한의사협회
- 이도병, "방사선촬영 보조기구를 이용한 팬텀 흉부 방사선 촬영에서 방사선 피폭선량과 영상 화질 비교에 관한 연구", 새물리, 68(7), pp.801~811 (2018), 한국물리학회
- 정성훈, "소아 흉부검사 시 격자 사용에 따른 영상 화질 평가", 방사선기술과학, 40(3), pp.371~376 (2017), 대한방사선과학회[DOI]
- 박상현, "X선 촬영 시 연령별 장기선량 차이 연구", 방사선방어학회지, 28(1) (2003), 테스트학회
- 허예지, "X선 촬영실에서 방호복 유무에 따른 공간산란선량의 측정 비교", 한국방사선학회논문지, 6(4), pp.313~320 (2012), 한국방사선학회[DOI]
- 서선열, "중증외상환자 CT 검사 시 검사보조자의 방사선피폭 경감을 위한 융합적 망토 차폐체의 유용성 연구", 한국융합학회논문지, 8(9), pp.211~216 (2017), 한국융합학회[DOI]
- 김창복, "방사선 소아촬영 : 방사선 소아촬영의 환경과 실제", 공학기술논문지, 7(4), pp.185~190 (2014), 공학기술연구원
- 곽종혁, "소아 방사선 검사 시 보호자 참여에 대한 인식도 조사", 한국방사선학회논문지, 8(4), pp.189~201 (2014), 한국방사선학회[DOI]
- "Standard guidelines for pediatric general radiology examinations), Radiation Safety Management Series No.35" (2013)[URL]
- 강아름, "소아 5세 표준촬영 가이드라인과 임상 촬영조건의 입사표면선량과 주요 장기흡수선량 비교", 방사선기술과학, 40(3), pp.355~361 (2017), 대한방사선과학회[DOI]
- "Development of the diagnostic reference level of pediatric radiography (10 years old)). Ministry of Korean Food & Drug Safety, 14171Radiation430;2014"[URL]
- 김지혜, "진단방사선 일반촬영에서의 X-ray Beam Collimator 사용 전국 실태조사", 의학물리, 24(2), pp.119~126 (2013), 한국의학물리학회
- PCXMC A Monte Carlo program for calculating patient doses in medical x‐ray examinations. 2nd ed, "Tapiovaara M", Radiation and Nuclear Safety Authority, ~, pp.Report STUK‐A139 2008 (2008)
- Servomaa A, "Organ dose calculation in medical X-ray examinations by the program PCXMC", Radiat Prot Dosimetry, 80, pp.213~219 (1998)[DOI]
- Johnson K, "Reducing unnecessary skull radiographs in children : A multidisciplinary audit", Clin Radiol, 59(7), pp.616~620 (2004)[DOI]
- Earl VJ, "Effective doses for common paediatric diagnostic general radiography examinations at a major Australian paediatric hospital and the communication of associated radiation risks", J Med Radiat Sci, 70(1), pp.30~39 (2023)[DOI]