Advanced modeled iterative reconstruction (ADMIRE) represents a repetitive reconstruction method that can adjust strength and kernel, each of which are known to affect computed tomography (CT) image quality. The aim of this study was to quantitatively analyze the noise and spatial resolution of CT images according to ADMIRE control factors. Patient im- ages were obtained by applying ADMIRE strength 2 and 3, and kernel B40 and B59. For quantitative evaluations, the noise level, spatial resolution, and overall image quality were measured using coefficient of variation (COV), edge rise distance (ERD), and natural image quality evaluation (NIQE). The superior values for the average COV, ERD, and NIQE results were obtained for the ADMIRE reconstruction conditions of ADMIRE 2 + B40, ADMIRE 3 + B59, and ADMIRE3 + B59. NIQE, which represents the overall image quality based on no-reference, was about 6.04 when using ADMIRE 3 + B59, showing the best result among the reconstructed image acquisition conditions. The results of this study indicate that the ADMIRE strength and kernel chosen for use in ADMIRE reconstruction have a significant impact on CT image quality. This highlights the importance of adjusting to the control factors in consideration of the clinical environment.

Abstract

Advanced modeled iterative reconstruction (ADMIRE) represents a repetitive reconstruction method that can adjust strength and kernel, each of which are known to affect computed tomography (CT) image quality. The aim of this study was to quantitatively analyze the noise and spatial resolution of CT images according to ADMIRE control factors. Patient im- ages were obtained by applying ADMIRE strength 2 and 3, and kernel B40 and B59. For quantitative evaluations, the noise level, spatial resolution, and overall image quality were measured using coefficient of variation (COV), edge rise distance (ERD), and natural image quality evaluation (NIQE). The superior values for the average COV, ERD, and NIQE results were obtained for the ADMIRE reconstruction conditions of ADMIRE 2 + B40, ADMIRE 3 + B59, and ADMIRE3 + B59. NIQE, which represents the overall image quality based on no-reference, was about 6.04 when using ADMIRE 3 + B59, showing the best result among the reconstructed image acquisition conditions. The results of this study indicate that the ADMIRE strength and kernel chosen for use in ADMIRE reconstruction have a significant impact on CT image quality. This highlights the importance of adjusting to the control factors in consideration of the clinical environment.

참고문헌 (26)

  1. Jeong HS, "Optimization of non-local means algorithm in low-dose computed tomographic image based on noise level and similarity evaluations", Journal of Radiological Science and Technology, 47(1), pp.39~48 (2024)[DOI]
  2. Kim JW, "Development of biopsy assist device on computed tomography using 3D printing technology", Journal of Radiological Science and Technology, 46(2), pp.151~157 (2023)[DOI]
  3. Yoon S, "Low-dose abdominopelvic computed tomography in patients with lymphoma : An image quality and radiation dose reduction study", PLoS One, 17(8), pp.e0272356~ (2022)[DOI]
  4. Kataria B, "Image quality and potential dose reduction using advanced modeled iterative reconstruction(admire)in abdominal CT : A review", Radiation Protection Dosimetry, 195(3-4), pp.177~187 (2021)[DOI]
  5. Ellmann S, "Advanced modeled iterative reconstruction(ADMIRE)facilitates radiation dose reduction in abdominal CT", Academic Radiology, 25, pp.1277~1284 (2018)[DOI]
  6. Richards PJ, "Spine computed tomography doses and cancer induction", Spine, 35(4), pp.430~433 (2010)[DOI]
  7. Naziroglu RE, "Simulation of scanner-and patient-specific low-dose CT imaging from existing CT images", Physica Medica, 36, pp.12~23 (2017)[DOI]
  8. Hsieh J, "Recent advances in CT image reconstruction", Current Radiology Reports, 1, pp.39~51 (2013)[DOI]
  9. Padole A, "CT radiation dose and iterative reconstruction techniques", AJR, 204, pp.W384~W392 (2015)[DOI]
  10. Geyer LL, "State of the Art : Iterative CT reconstruction techniques", Radiology, 276(2), pp.339~357 (2015)[DOI]
  11. Solomon J, "Diagnostic performance of an advanced modeled iterative reconstruction algorithm for low-contrast detectability with a third-generation dual-source multidetector CT scanner : Potential for radiation dose reduction in a multireader study", Radiology, 275(3), pp.735~745 (2015)[DOI]
  12. Anja Ö, "Image quality of CT angiography of supra-aortic arteries", Clinical Neuroradiology, 30, pp.101~107 (2020)[DOI]
  13. Gordic S, "Advanced modelled iterative reconstruction for abdominal CT : Qualitative and quantitative evaluation", Clinical Radiology, 69, pp.e497~e504 (2014)[DOI]
  14. Rompel O, "Third-generation dual-source 70-kVp chest CT angiography with advanced iterative reconstruction in young children : Image quality and radiation dose reduction", Pediatric Radiology, 46, pp.462~472 (2016)[DOI]
  15. Weiss KL, "Hybrid convolution kernel : Optimized CT of the head, neck, and spine", AJR, 196, pp.403~406 (2011)[DOI]
  16. Gierada DS, "Effects of CT section thickness and reconstruction kernel on emphysema quantification : Relationship to the magnitude of the CT emphysema index", Academic Radiology, 17, pp.146~156 (2010)[DOI]
  17. Gordic S, "Ultralow-dose chest computed tomography for pulmonary nodule detection", Investigative Radiology, 49(7), pp.465~473 (2014)[DOI]
  18. Denzinger F, "How scan parameter choice affects deep learning‑based coronary artery disease assessment from computed tomography", Scientific Reports, 13 (2023)[DOI]
  19. Tatsugami F, "Coronary artery stent evaluation with model-based iterative reconstruction at coronary CT angiography", Academic Radiology, 24, pp.975~981 (2017)[DOI]
  20. Mittal A, "Making a"Completely Blind"image quality analyzer", IEEE Signal Processing Letters, 20(3), pp.209~212 (2013)[DOI]
  21. Gordic S, "Optimizing radiation dose by using advanced modelled iterative reconstruction in high-pitch coronary CT angiograph", European Radiology, 26(2), pp.459~468 (2016)[DOI]
  22. Hayashi R, "Real-time CT image generation based on voxel-by-voxel modeling of internal deformation by utilizing the displacement of fiducial markers", Medical Physics, 48, pp.5311~5326 (2021)[DOI]
  23. Joemai RMS, "Assessment of structural similarity in CT using filtered backprojection and iterative reconstruction : A phantom study with 3D printed lung vessels", The British Journal of Radiology, 90, pp.20160519~ (2017)[DOI]
  24. Shin JB, "Comparative performance analysis for abdominal phantom ROI detectability according to CT reconstruction algorithm : ADMIRE", Journal of Applied Clinical Medical Physics, 21(1), pp.136~143 (2020)[DOI]
  25. Solomon JB, "Quantitative comparison of noise texture across CT scanners from different manufacturers", Medical Physics, 39(10), pp.6048~6055 (2012)[DOI]
  26. Lim S, "Optimization of median modified wiener filter for improving lung segmentation performance in low-dose computed tomography images", Applied Sciences, 13(19), pp.10679~ (2023)[DOI]

관련 논문AI추천

Image Evaluation and Exposure Dose with the Application of Tube Voltage and Adaptive Statistical Iterative Reconstruction of Low Dose Computed Tomography김기정, 문태준, 이혜남대한방사선과학회 · Journal of Radiological Science and Technology2017 · 제40권 제2호전산화단층촬영에서 관전압과 관전류, 통계적 반복재구성법에 따른 화질과 피폭선량김정훈, 박재윤, 이용기, 차상영, 최재호대한방사선과학회 · Journal of Radiological Science and Technology2017 · 제40권 제3호To compare the image quality of high resolution CT scan of temporal bone reconstructed using novel adaptive statistical iterative reconstruction-v technique with conventional filter back projection reconstruction techniquePreethi P., Ruth Monica V.한국원자력학회 · Nuclear Engineering and Technology2025 · 제57권 제11호노이즈 레벨 및 유사도 평가 기반 저선량 조건의 전산화 단층 검사 영상에서의 비지역적 평균 알고리즘의 최적화김이준, 박수빈, 박수연, 서강현, 오윤지, 이영진, 이우석, 정하선대한방사선과학회 · Journal of Radiological Science and Technology2024 · 제47권 제1호반복적 연산으로 얻은 Sparse-view CT 영상에 대한 정량적 평가김혜선, 이수열, 조민형, Gao Jie대한의용생체공학회 · 의공학회지2011 · 제32권 제3호Noise reduction in low-dose positron emission tomography with adaptive parameter estimation in sinogram domain김규범, 김규석, 김연경, 이수환한국원자력학회 · Nuclear Engineering and Technology2024 · 제56권 제10호

이 간행물의 다른 논문 (5건)