초록

In the process of reconstructing SPECT-CT fusion images, we analyzed and evaluated the effect of the photon energy difference between the gamma rays used in SPECT and the X-rays used in CT on attenuation correction through phan- tom experiments. We selected 99mTc (281.20 M㏃), which emits low-energy gamma rays of 140 keV, and 131I (98.42 M㏃), which emits high-energy gamma rays of 364 keV, as radioactive tracers. A Jaszczak SPECT phantom was created, and images were acquired using a SPECT-CT scanner. Afterward, using an image analysis program, we classified the images into categories based on Total Uniformity and Center to Edge Ratio before and after attenuation correction. Total Uniformity was analyzed by setting a region of interest (ROI) in the image of all the phantom slices combined, while the Center to Edge Ratio was analyzed by setting a 2 ㎝ diameter difference between the Total ROI and the Inner ROI. The results showed that the Total Uniformity of the 99mTc phantom image improved by 10.13%, from 87.42±1.26 before attenuation correction to 96.28±0.42 after. Additionally, the Center to Edge Ratio improved by 4.67%, from 1.07 before attenuation correction to 1.02 after. The Total Uniformity of the 131I phantom image decreased by 0.01%, from 91.56±1.48 before attenuation correction to 91.55±2.64 after. Furthermore, the Center to Edge Ratio decreased by 6.86%, from 1.02 before attenuation correction to 1.09 after. The attenuation correction of X-rays based on the physical properties of the energy, type, radioactivity, and physical half-life of radioactive tracers in Hybrid SPECT-CT can improve image uniformity.

Abstract

In the process of reconstructing SPECT-CT fusion images, we analyzed and evaluated the effect of the photon energy difference between the gamma rays used in SPECT and the X-rays used in CT on attenuation correction through phan- tom experiments. We selected 99mTc (281.20 M㏃), which emits low-energy gamma rays of 140 keV, and 131I (98.42 M㏃), which emits high-energy gamma rays of 364 keV, as radioactive tracers. A Jaszczak SPECT phantom was created, and images were acquired using a SPECT-CT scanner. Afterward, using an image analysis program, we classified the images into categories based on Total Uniformity and Center to Edge Ratio before and after attenuation correction. Total Uniformity was analyzed by setting a region of interest (ROI) in the image of all the phantom slices combined, while the Center to Edge Ratio was analyzed by setting a 2 ㎝ diameter difference between the Total ROI and the Inner ROI. The results showed that the Total Uniformity of the 99mTc phantom image improved by 10.13%, from 87.42±1.26 before attenuation correction to 96.28±0.42 after. Additionally, the Center to Edge Ratio improved by 4.67%, from 1.07 before attenuation correction to 1.02 after. The Total Uniformity of the 131I phantom image decreased by 0.01%, from 91.56±1.48 before attenuation correction to 91.55±2.64 after. Furthermore, the Center to Edge Ratio decreased by 6.86%, from 1.02 before attenuation correction to 1.09 after. The attenuation correction of X-rays based on the physical properties of the energy, type, radioactivity, and physical half-life of radioactive tracers in Hybrid SPECT-CT can improve image uniformity.

참고문헌 (36)

  1. Venkatram P, "Other diagnostic modalities, advantages and disadvantages in different pathologic conditions", Heart Diseases and Echocardiogram, pp.783~787 (2024)[DOI]
  2. Ritt P, "Recent developments in SPECT", CT, 2022, pp.52(3), 276~285
  3. Cantoni V, "Diagnostic performance of myocardial perfusion imaging with conventional and CZT single-photon emission computed tomography in detecting coronary artery disease : A meta-analysis", Journal of Nuclear Cardiology, 28(2), pp.698~715 (2021)[DOI]
  4. Beck M, "Tratamiento de las hernias inguinales estranguladas", Técnicas Quirúrgicas, 32(1), pp.1~9 (2016)[DOI]
  5. Hricak H, "et al. Medical imaging and nuclear medicine : A Lancet Oncology Commission", The Lancet Oncology, 22(4), pp.e136~e72 (2021)[DOI]
  6. Weber WA, "The future of nuclear medicine, molecular imaging, and theranostics", Journal of Nuclear Medicine, 61(2), pp.263~272 (2020)[DOI]
  7. Ge J, "Radiolabeling nanomaterials for multimodality imaging : New insights into nuclear medicine and cancer diagnosis", Biomaterials, 228, pp.119553~ (2020)[DOI]
  8. Yang J, "Direct attenuation correction using deep learning for cardiac SPECT : A feasibility study", Journal of Nuclear Medicine, 62(11), pp.1645~1652 (2021)[DOI]
  9. Du Y, "Deep-learning-based estimation of attenuation map improves attenuation correction performance over direct attenuation estimation for myocardial perfusion SPECT", Journal of Nuclear Cardiology, 30(3), pp.1022~1037 (2023)[DOI]
  10. Liu H, "Post-reconstruction attenuation correction for SPECT myocardium perfusion imaging facilitated by deep learning-based attenuation map generation", Journal of Nuclear Cardiology, 29(6), pp.2881~2892 (2022)[DOI]
  11. Prieto Canalejo MA, "Synthetic attenuation correction maps for SPECT imaging using deep learning : A study on myocardial perfusion imaging", Diagnostics, 13(13), pp.2214~ (2023)[DOI]
  12. Kovan B, "The effects of kilovoltage(kV)and milliampere seconds(mAs)values for SPECT attenuation correction : An anthropomorphic phantom study", Applied Radiation and Isotopes, 204, pp.111118~ (2024)[DOI]
  13. Peștean C, "The role of SPECT", CT and PET, Diagnostics, pp.2024, 14(13)[DOI]
  14. Frantellizzi V, "Hybrid imaging of vascular cognitive impairment", Seminars in Nuclear Medicine, 51(3), pp.286~295 (2021)[DOI]
  15. Vallabhajosula S, "Molecular Imaging and Targeted Therapy: Radiopharmaceuticals and Clinical Applications", pp.63~86 (2023)
  16. Caravaca J, "Compton and proximity imaging of Ac in vivo with a CZT gamma camera : A proof of principle with simulations", IEEE Transactions on Radiation and Plasma Medical Sciences, 6(8), pp.904~915 (2022)[DOI]
  17. Alshammari H, "Imaging ability of the compton imaging system (Gri+) for thyroid phantom filled with 99mTc", IEEE Nuclear Science Symposium and Medical Imaging Conference(NSS, 2021, 1~3
  18. Camoni L, "Best practice for the nuclear medicine technologist in CT-based attenuation correction and calcium score for nuclear cardiology", European Journal of Hybrid Imaging, 4, pp.1~20 (2020)[DOI]
  19. Yamamoto T, "Development of a new cardiac and torso phantom for verifying the accuracy of myocardial perfusion SPECT", Journal of Radiological Science and Technology, 31(4), pp.389~400 (2008)
  20. Duatti A, "Review on 99mTc radiopharmaceuticals with emphasis on new advancements", Nuclear Medicine and Biology, 92, pp.202~216 (2021)[DOI]
  21. Lengacher R, "Bioorganometallics : 99mTc cytectrenes, syntheses and applications in nuclear medicine", Coordination Chemistry Reviews, 437, pp.213869~ (2021)[DOI]
  22. Vermandel M, "Management of patients with renal failure undergoing dialysis during 131I therapy for thyroid cancer", Journal of Nuclear Medicine, 61(8), pp.1161~1170 (2020)[DOI]
  23. Halim F, "Accuracy assessment of SUV measurements in SPECT", CT : A phantom study, 2021, pp.49(3), 250~255
  24. Pribanić I, "Reduction of SPECT acquisition time using deep learning : A phantom study", Physica Medica, 111, pp.102615~ (2023)[DOI]
  25. Noori-Asl M, "Investigation of different factors affecting the quality of SPECT images : A simulation study", Journal of Medical Physics, 45(1), pp.44~51 (2020)[DOI]
  26. Ritt P, "Quantitative SPECT", CT—technique and clinical applications, 2020, 565~590
  27. Frelih N, "The effect of attenuation correction on image quality in single photon emission computed tomography : The effect of attenuation correction on image quality", Medical Science and Discovery, 8(2), pp.73~78 (2021)[DOI]
  28. Chen EJ, "Quantitative analysis of xQuant reconstruction algorithm in SPECT", CT, 2021, pp.188, 109683~
  29. Cheng L, "An integrated framework of projection and attenuation correction for quantitative SPECT", CT reconstruction, 2021 (2021), 1~3[DOI]
  30. Tran-Gia J, "On the use of solid 133Ba sources as surrogate for liquid 131I in SPECT", CT calibration : A European multi-centre evaluation, 2023, pp.10, 73~
  31. Teuho J, "Magnetic resonance-based attenuation correction and scatter correction in neurological positron emission tomography", magnetic resonance imaging—current status with emerging applications, 2020, pp.7, 243~
  32. Huizing DM, "177Lutetium SPECT", CT : Evaluation of collimator, photopeak and scatter correction, 2020, pp.21(9), 272~277
  33. Hadjiconstanti A, "The impact of two scatter correction methods on I-131 AC-SPECT images using an anthropomorphic phantom with variable sizes of thyroid remnants", Proceedings of the 2020 7th International Conference on Biomedical and Bioinformatics Engineering, pp.51~58 (2020)
  34. Morphis M, "Evaluation of Iodine-123 and Iodine-131 SPECT activity quantification : A Monte Carlo study", EJNMMI Physics, 8, pp.1~20 (2021)[DOI]
  35. Bae JK, "Development of unmatched system model for iterative image reconstruction for pinhole collimator of imaging systems in nuclear medicine", Journal of Radiological Science and Technology, 35(4), pp.353~360 (2012)
  36. Michael K, "The impact of dual and triple energy window scatter correction on I-123postsurgical thyroid SPECT", CT imaging using a phantom with small sizes of thyroid remnants, 2024, pp.13(4), 961~

관련 논문AI추천

이 간행물의 다른 논문 (14건)